steve
Got hold of Sime for a Carrier card for…
Got hold of Sime for a Carrier card for a chiller. Machine down in a factory. Received the new card in express time machine and plant now up and running fantastic service form Sime
3 weeks ago
Full 12-month warranty
Available for dispatch immediately
We deliver worldwide
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
All orders are subject to product availability. See our T&Cs.
Ask our team
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
| Specification | Description |
|---|---|
| Manufacturer | Telemecanique |
| Part Number | XY2CJS15 |
| Product Type | Latching emergency stop rope pull switch |
| Series / Range | XY2C / XY2CJ |
| Device Configuration | Straight rope pull switch with pull-button reset |
| Contact Arrangement | 1 normally closed and 1 normally open contact |
| Terminal Identification | NO: 13-14; NC: 21-22 |
| Contact Operation | Slow-break contact operation |
| Reset Method | Pull button |
| Cable Entry | 1 tapped Pg 13.5 cable gland entry |
| Maximum Rope Length | 20 m / 65.6 ft |
| Cable Anchor Position | Right-hand or left-hand side |
| Rated Operational Current | 3 A at 240 V AC-15, A300; 0.27 A at 250 V DC-13, Q300 |
| Conventional Enclosed Thermal Current | 10 A |
| Rated Insulation Voltage | 500 V according to EN/IEC 60947-1; 300 V according to UL 508 and CSA C22.2 No. 14 |
| Rated Impulse Withstand Voltage | 6 kV |
| Short-Circuit Protection | 10 A gG cartridge fuse |
| Mechanical Durability | 100,000 operating cycles |
| B10d Reliability Value | 500,000 operations |
| Enclosure Color | Red RAL 3000 |
| Body Material | Zamak |
| Head Material | PA polyamide |
| Cover Material | Galvanized steel |
| Connection Type | Screw clamp terminals for 1 x 0.5 to 2 x 1.5 mm² conductors |
| Tightening Torque | 0.8 to 1.2 N.m / 7.08 to 10.6 lbf.in |
| Local Indication | Color indicator |
| IP Rating | IP66 and IP67 according to IEC 60529 |
| Operating Temperature | -25 to 70 °C / -13 to 158 °F |
| Storage Temperature | -40 to 70 °C / -40 to 158 °F |
| Vibration Resistance | 10 gn from 10 to 150 Hz according to EN/IEC 60068-2-6 |
| Shock Resistance | 50 gn for 11 ms according to EN/IEC 60068-2-27 |
| Standards | EN/IEC 60947-5-1, EN/IEC 60947-5-5, EN/ISO 13850, EN/IEC 60204-1, UL 508, CSA C22.2 No. 14 |
| Product Certifications | UL category NISD emergency stop devices, CSA, CCC, EAC |
| Marking | CE |
| Net Weight | 0.455 kg / 1.00 lb |
| GTIN | 3389119619509 |
| Commodity Code | 853650 |
It is a latching emergency stop rope pull switch from the Telemecanique XY2CJ range, designed for use with a tensioned pull cable so an emergency stop command can be triggered from along a machine or conveyor line.
The switch has a 1 NC + 1 NO contact arrangement. The ISO terminal designations are 21-22 for the normally closed contact and 13-14 for the normally open contact.
The maximum trigger cable length is 65.6 ft, equivalent to 20 m. The recommended distance between cable fixing points is 16.4 ft, equivalent to 5 m.
The device is reset by a pull button. As a latching rope pull switch, it remains in the actuated state until it is manually reset.
XY2CJS15 has one tapped cable entry for a Pg 13.5 cable gland.
The rated operational current is 3 A at 240 V AC-15, A300, and 0.27 A at 250 V DC-13, Q300. The conventional enclosed thermal current is 10 A.
It uses screw clamp terminals suitable for conductors from 1 x 0.5 mm² to 2 x 1.5 mm². The specified tightening torque is 0.8 to 1.2 N.m, or 7.08 to 10.6 lbf.in.
The enclosure is rated IP66 and IP67 according to IEC 60529, giving protection against dust ingress and high levels of water exposure when correctly installed.
The operating temperature range is -13 to 158 °F, equivalent to -25 to 70 °C. The storage temperature range is -40 to 158 °F, equivalent to -40 to 70 °C.
The body is made from Zamak, the head is PA polyamide, and the cover is galvanized steel. The housing is red, RAL 3000.
The switch has a specified mechanical durability of 100,000 cycles. Its B10d value is 500,000, based on IEC 60947-5-5.
The listed standards include EN/IEC 60947-5-1, EN/IEC 60947-5-5, EN/ISO 13850, EN/IEC 60204-1, UL 508, CSA C22.2 No. 14, Machinery Directive 2006/42/EC, and Work Equipment Directive 2009/104/EC. Certifications include UL category NISD emergency stop devices, CSA, CCC, and EAC.
This content has been produced using multiple sources. EU Automation takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
All parts new or reconditioned are covered by EU Automation 12 month warranty
No hassle returns policy
Dedicated customer support team
We understand that credit is a necessary part of business and offer credit agreements on request, subject to status.
Payment optionsWe accept Bank transfers and the following methods of payment:
All transactions are handled securely by HSBC and HSBC Merchant Services. For more information, please visit our dedicated payments page.
Global supplier of quality automation and control components
Dispose of your old unit by exchanging it for a working part.
A comprehensive repair service for faulty equipment.
You don’t need tights and a cape to be a hero.
Get parts fast and feel like a legend, just like Jeff.