steve
Got hold of Sime for a Carrier card for…
Got hold of Sime for a Carrier card for a chiller. Machine down in a factory. Received the new card in express time machine and plant now up and running fantastic service form Sime
3 weeks ago
Full 12-month warranty
Available for dispatch immediately
We deliver worldwide
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
All orders are subject to product availability. See our T&Cs.
Ask our team
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
| Specification | Description |
|---|---|
| Part Number | LX1D6E7 |
| Manufacturer | Telemecanique |
| Product Type | Contactor coil |
| Range | TeSys D |
| Device Short Name | LX1D6 |
| Control Circuit Type | AC coil for 50/60 Hz operation |
| Rated Control Circuit Voltage | 48 V AC |
| Frequency | 50/60 Hz |
| Compatible Contactors | LC1D80 and LC1D95 |
| Average Resistance | 5 Ohm at 20 °C |
| Closed-Circuit Inductance | 0.32 H |
| Coil Technology | Without built-in suppressor module |
| Drop-Out Voltage Range | 0.3 to 0.6 Uc at 55 °C |
| Operational Voltage Range at 50 Hz | 0.8 to 1.1 Uc at 55 °C |
| Operational Voltage Range at 60 Hz | 0.85 to 1.1 Uc at 55 °C |
| Inrush Power Consumption | 245 VA at 20 °C, cos φ 0.75, at 50 Hz and 60 Hz |
| Hold-In Power Consumption | 26 VA at 20 °C, cos φ 0.3, at 50 Hz and 60 Hz |
| Heat Dissipation | 6 to 10 W at 50/60 Hz |
| Mechanical Durability | 4 million operating cycles |
| Maximum Operating Rate | 3600 cycles per hour at ≤ 60 °C |
| Operating Ambient Temperature | -5 to +60 °C |
| Product Weight | 0.28 kg |
| RoHS Status | Compliant |
| REACh Status | Does not contain SVHC above the threshold |
This component is a replacement control coil used to energise compatible TeSys D contactors. When the correct AC control voltage is applied, it creates the magnetic force needed to pull in and hold the contactor.
It is designed for use with TeSys D contactors in the LC1D80 and LC1D95 sizes. If you are matching an existing assembly, checking the contactor model before purchase is the best way to confirm suitability.
This coil is rated for 48 V AC at 50/60 Hz. In many applications, it is selected where the control circuit uses a 48-volt AC supply rather than a DC control voltage.
Yes. It is intended for AC 50/60 Hz operation, making it suitable for installations that use either supply frequency at the stated control voltage.
No. This version uses coil technology without a built-in suppressor module. If suppression is needed in the control circuit, that would normally be considered separately at the panel design stage.
At 55°C, the drop-out range is 0.3 to 0.6 x Uc. The operational range is 0.8 to 1.1 x Uc at 50 Hz and 0.85 to 1.1 x Uc at 60 Hz. For a 48 V AC coil such as LX1D6E7, this helps indicate the expected pull-in and release behaviour under normal conditions.
The inrush power is 245 VA at 20°C for both 50 Hz and 60 Hz. The hold-in power consumption is 26 VA at 20°C for both frequencies. These figures are useful when assessing control transformer loading and circuit design.
The average resistance is 5 Ohm at 20°C, and the inductance of the closed circuit is 0.32 H. These electrical characteristics can be helpful when comparing against an existing installed coil.
The stated ambient operating temperature range is -5°C to 60°C. This makes it suitable for a wide range of industrial panel environments, provided the rest of the installation is also rated appropriately.
The mechanical durability is rated at 4 million cycles, with an operating rate of up to 3600 cycles per hour at temperatures up to 60°C. This makes it a practical choice for repeated switching duties within its intended application.
The heat dissipation is listed at 6 to 10 W at 50/60 Hz. This can be a useful consideration when reviewing enclosure layout and thermal conditions inside a control panel.
The product weight is approximately 0.28 kg. This is a relatively compact coil assembly intended for the compatible larger-frame TeSys D contactors.
This content has been produced using multiple sources. EU Automation takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
All parts new or reconditioned are covered by EU Automation 12 month warranty
No hassle returns policy
Dedicated customer support team
We understand that credit is a necessary part of business and offer credit agreements on request, subject to status.
Payment optionsWe accept Bank transfers and the following methods of payment:
All transactions are handled securely by HSBC and HSBC Merchant Services. For more information, please visit our dedicated payments page.
Global supplier of quality automation and control components
Dispose of your old unit by exchanging it for a working part.
A comprehensive repair service for faulty equipment.
You don’t need tights and a cape to be a hero.
Get parts fast and feel like a legend, just like Jeff.