steve
Got hold of Sime for a Carrier card for…
Got hold of Sime for a Carrier card for a chiller. Machine down in a factory. Received the new card in express time machine and plant now up and running fantastic service form Sime
3 months ago
Full 12-month warranty
Available for dispatch immediately
We deliver worldwide
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
All orders are subject to product availability. See our T&Cs.
Ask our team
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
| Specification | Description |
|---|---|
| Part Number | LR2D1307 |
| Manufacturer | Telemecanique |
| Series | LR2D |
| Type | Overload Relay |
| Application | Motor Protection |
| Operational Voltage | 690 V AC 50/60 Hz for power circuit |
| Control Circuit Voltage | Up to 690 V AC |
| Adjustable Current Range | 1.6 to 2.5 A |
| Tripping Class | Class 10A |
| Contacts Configuration | 1 Normally Open (NO), 1 Normally Closed (NC) |
| Mounting Support | Plate with EverLink power terminal block, Rail with EverLink power terminal block |
| Tripping Threshold | 1.14 +/-0.06 In A conforming to IEC 60947-4-1 |
| Phase Failure Sensitivity | Tripping current I 30% of Ir on one phase, the others at Ir conforming to IEC 60947-4-1 |
| Ambient Air Temperature | For operation -20...60 °C conforming to IEC 60947-4-1 |
| Protective Treatment | TH conforming to IEC 60068 |
| IP Degree of Protection | IP2x conforming to VDE 0106 |
| Fire Resistance | 850 °C conforming to IEC 60695-2-1 |
| Shock Resistance | 15 gn 11 ms conforming to IEC 60068-2-7 |
| Vibration Resistance | 6 gn on plate conforming to IEC 60068-2-6 |
| Dielectric Strength | 6 kV at 50 Hz conforming to IEC 60255-5 |
| Network Frequency | 50/60 Hz |
| Tightening Torque | Control circuit: 1.7 N.m - on screw clamp terminals |
| Dimensions (H x W x D) | 121 mm x 75 mm x 100 mm |
| Standards and Certifications | ATEX, INERIS, BV, CCC, CSA, DNV GL, GOST, LROS, RINA, UL, EN 60947-4-1, EN 60947-5-1, IEC 60947 |
| Product Status | Discontinued |
An overload relay is designed to protect an electric motor from overheating by detecting an overload condition and interrupting the current flow to the motor, thus preventing potential damage.
The LR2D1307 thermal overload relay protects a motor by using a bimetallic strip that heats up and bends when excessive current flows through it, triggering a mechanism that opens the circuit and stops the motor.
Yes, the LR2D1307 can be used with any motor as long as the motor's full load current falls within the 1.6 to 2.5 A range that the relay is designed to handle.
The LR2D1307 can be mounted on a plate with EverLink power terminal block or on a rail with EverLink power terminal block, providing flexibility for different installation requirements.
The tripping threshold indicates the current level at which the relay will trip to protect the motor. For the LR2D1307, it is set at 1.14 +/-0.06 times the rated current (In) of the relay, conforming to IEC 60947-4-1 standards.
Yes, the LR2D1307 has phase failure sensitivity, meaning it will trip if the current on one phase drops to 30% of the rated current while the others remain at the rated current, as per IEC 60947-4-1.
The LR2D1307 is certified with several standards including ATEX, EN 60947-4-1, EN 60947-5-1, IEC 60947-4-1, IEC 60947-5-1, and UL 508, ensuring compliance with international safety and quality requirements.
The LR2D1307 is rated for operational voltages up to 690 V AC 50/60 Hz for the power circuit, conforming to IEC 60947-4-1.
The LR2D1307 is designed to operate within an ambient air temperature range of -20 to 60 °C, conforming to IEC 60947-4-1.
The LR2D1307 supports screw clamp terminals for control circuits, accommodating cables from 1 to 2.5 mm² in size, with flexibility for both solid and flexible cables with or without cable ends.
This content has been produced using multiple sources. EU Automation takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
All parts new or reconditioned are covered by EU Automation 12 month warranty
No hassle returns policy
Dedicated customer support team
We understand that credit is a necessary part of business and offer credit agreements on request, subject to status.
Payment optionsWe accept Bank transfers and the following methods of payment:
All transactions are handled securely by HSBC and HSBC Merchant Services. For more information, please visit our dedicated payments page.
Global supplier of quality automation and control components
Dispose of your old unit by exchanging it for a working part.
A comprehensive repair service for faulty equipment.
You don’t need tights and a cape to be a hero.
Get parts fast and feel like a legend, just like Jeff.