steve
Got hold of Sime for a Carrier card for…
Got hold of Sime for a Carrier card for a chiller. Machine down in a factory. Received the new card in express time machine and plant now up and running fantastic service form Sime
2 months ago
Full 12-month warranty
Available for dispatch immediately
We deliver worldwide
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
All orders are subject to product availability. See our T&Cs.
Ask our team
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
| Specification | Description |
|---|---|
| Manufacturer | Telemecanique |
| Part number | A9MEM3310 |
| Series | Acti 9 |
| Product range | Acti 9 iEM3000 |
| Device short name | IEM3310 |
| Product type | Energy meter |
| Part description | DIN-rail mounted electronic energy meter for measuring active energy on single-phase or three-phase installations, featuring an LCD display and a pulse output for external counting and monitoring. |
| Type of measurement | Active energy |
| Typical application | Sub-billing; partial metering |
| Poles configuration supported | 1P + N; 3P; 3P + N |
| Input type | Direct input |
| Rated current (In) | 125 A |
| Measurement current range | 0…125 A |
| Rated voltage | 100…277 V; 173…480 V |
| Network frequency | 50/60 Hz |
| Technology | Electronic |
| Display type | LCD display |
| Sampling rate | 32 samples/cycle |
| Maximum energy value displayed | 99,999,999.9 kWh |
| Number of outputs | 1 pulse |
| Number of inputs | 0 |
| Communication port | None |
| Local indication | Green indicator: power ON; yellow flashing LED: accuracy checking |
| Mounting mode | Clip-on |
| Mounting support | DIN rail |
| Terminal type | Screw terminals |
| Maximum cable size | 50 mm² |
| Overvoltage category | III |
| IP rating | IP40 (front panel); IP20 (body) |
| Pollution degree | 2 |
| Relative humidity | 5…95% at 50 °C |
| Operating temperature | -25…55 °C (MID); -25…60 °C (IEC/NMI) |
| Storage temperature | -40…85 °C |
| Operating altitude | < 2000 m |
| Colour | White |
| Width | 126 mm |
| Height | 103.2 mm |
| Depth | 69.3 mm |
| 9 mm pitches | 14 |
| Standards | IEC 61036; IEC 61557-12; IEC 62053-21; IEC 62053-23; IEC 61010; UL 61010-1 |
| Product certifications | CE; CULus; UL; EAC (sub-meter); RCM (NMI M 6-1); MID (EN 62052, EN 50470-3) |
It measures active energy consumption (kWh) using an electronic metering method, making it suitable for tracking electricity usage over time.
It supports multiple pole configurations: 1P + N, 3P, and 3P + N, so it can be applied to both single-phase and three-phase installations depending on how it is wired.
The rated voltage ranges are 100…277 V and 173…480 V, covering many common low-voltage distribution systems.
It is rated for 125 A with direct current measurement from 0…125 A (direct input, no external CTs required within this range).
Yes. It is designed for 50/60 Hz networks.
Active energy accuracy is Class 1 to IEC 62053-21 and IEC 61557-12, and Class B to EN 50470-3.
Yes. It is intended for sub-billing and partial metering applications, commonly used for cost allocation across tenants, panels, or internal departments.
No. This variant does not provide a communication port protocol or communication port support; it focuses on local display plus a pulse output.
It provides 1 pulse output, which can be used for external counting or simple energy logging via a compatible pulse counter/PLC input.
It includes an LCD display plus local LEDs: a green indicator for power ON and a yellow flashing LED for accuracy checking.
The maximum value measured is 99,999,999.9 kWh.
It is DIN-rail mountable with a clip-on mounting mode, designed for straightforward installation in distribution boards.
It uses screw terminals and supports cables up to 50 mm².
The front panel is rated IP40 and the body is rated IP20 (per IEC 60529).
Typical operating ambient ranges are -25…60 °C (IEC/NMI) and -25…55 °C (MID), with relative humidity 5–95% at 50 °C and operating altitude up to 2000 m.
It is approximately 126 mm wide, 103.2 mm high, and 69.3 mm deep, occupying 14 pitches of 9 mm. The catalogue reference for this configuration is A9MEM3310.
This content has been produced using multiple sources. EU Automation takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
All parts new or reconditioned are covered by EU Automation 12 month warranty
No hassle returns policy
Dedicated customer support team
We understand that credit is a necessary part of business and offer credit agreements on request, subject to status.
Payment optionsWe accept Bank transfers and the following methods of payment:
All transactions are handled securely by HSBC and HSBC Merchant Services. For more information, please visit our dedicated payments page.
Global supplier of quality automation and control components
Dispose of your old unit by exchanging it for a working part.
A comprehensive repair service for faulty equipment.
You don’t need tights and a cape to be a hero.
Get parts fast and feel like a legend, just like Jeff.