steve
Got hold of Sime for a Carrier card for…
Got hold of Sime for a Carrier card for a chiller. Machine down in a factory. Received the new card in express time machine and plant now up and running fantastic service form Sime
2 months ago
Full 12-month warranty
Available for dispatch immediately
We deliver worldwide
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
All orders are subject to product availability. See our T&Cs.
Ask our team
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
| Specification | Description |
|---|---|
| Part Number | 6SL3511-1PE27-5AQ0 |
| Alternative Part Number | 6SL35111PE275AQ0 |
| Manufacturer | Siemens |
| Voltage Range | 380 ... 500 V 3 AC |
| Rated Output | Various values depending on the load point, with a maximum ambient temperature without derating of 40 °C |
| Rated Output Current | Based on the load cycle for high overload HO |
| Rated Apparent Power | Corresponds to the rated output current IN |
| Power Loss Data | According to IEC 61800-9-2, includes absolute and relative converter losses |
| IE Class | IE2 |
| Frame Size | FSA, FSB, FSC (varies based on specific configurations) |
| Operating Points | Includes partial load points with relative motor stator frequency and relative torque current |
| Standby Mode Losses | Provided for the converter when not supplying power to the motor |
| Electronics Power Supply | Can be supplied via an internal or external 24 V electronics power supply |
| Additional Features | Control Unit can be operated via an external 24 V electronics power supply in standby mode |
This Siemens distributed converter is designed for decentralised drive solutions, providing efficient and precise control of motors in a variety of industrial applications such as conveyor systems, fans, and pumps.
The suitability of the converter for outdoor applications depends on the specific environmental conditions and the level of protection provided by the installation. It's important to refer to the product specifications and ensure that the converter is housed in an appropriate enclosure if necessary.
The converter operates within a voltage range of 380 to 500 V 3 AC, as per the specifications. It's crucial to ensure that the supply voltage matches the requirements for optimal performance.
The converter is rated for a maximum ambient temperature of 40°C without derating. Operating it beyond this temperature may affect performance and longevity, so it's important to maintain an appropriate operating environment.
The IE class refers to the efficiency classification of the converter. Higher IE classes indicate better energy efficiency, which can lead to energy savings and reduced operational costs over time.
Power loss data for the converter can be determined according to IEC 61800-9-2 standards. This information is crucial for planning the thermal management of the control cabinet where the converter is installed.
These designations refer to the frame size of the converter, which is related to the physical dimensions and power capacity of the device. It's important to select the correct frame size for your application to ensure compatibility and proper function.
Yes, the converter features a standby mode where it does not supply power to the motor. This mode significantly reduces power consumption, which can contribute to energy savings when the drive is not in active use.
The control unit can indeed be operated with an external 24 V electronics power supply, which is useful in standby mode. However, losses from the external power supply should be considered for control cabinet cooling.
When integrating the converter into a control cabinet, it's important to consider the power loss data for thermal management, ensure that the voltage and current ratings are compatible, and that there is sufficient space for the frame size of the converter.
This content has been produced using multiple sources. EU Automation takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
All parts new or reconditioned are covered by EU Automation 12 month warranty
No hassle returns policy
Dedicated customer support team
We understand that credit is a necessary part of business and offer credit agreements on request, subject to status.
Payment optionsWe accept Bank transfers and the following methods of payment:
All transactions are handled securely by HSBC and HSBC Merchant Services. For more information, please visit our dedicated payments page.
Global supplier of quality automation and control components
Dispose of your old unit by exchanging it for a working part.
A comprehensive repair service for faulty equipment.
You don’t need tights and a cape to be a hero.
Get parts fast and feel like a legend, just like Jeff.