steve
Got hold of Sime for a Carrier card for…
Got hold of Sime for a Carrier card for a chiller. Machine down in a factory. Received the new card in express time machine and plant now up and running fantastic service form Sime
2 months ago
Full 12-month warranty
Available for dispatch immediately
We deliver worldwide
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
All orders are subject to product availability. See our T&Cs.
Ask our team
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
| Specification | Description |
|---|---|
| Manufacturer | Siemens |
| Part Number | 6SL3320-1TG32-2AA3 |
| Alternative Part Number | 6SL33201TG322AA3 |
| Product Type | High-power motor module for industrial drive applications |
| Construction | Chassis format |
| Type Rating Based on IN | 200 kW |
| Type Rating Based on IH | 160 kW |
| Rated Output Current IN | 215 A |
| Base-Load Current IL | 208 A |
| Base-Load Current IH | 192 A |
| Maximum Output Current | 312 A |
| DC-Link Voltage | 675–1,035 V DC |
| Rated DC-Link Current with Basic/Smart Line Module | 258 A |
| Rated DC-Link Current with Active Line Module | 232 A |
| Base-Load Current IL DC with Basic/Smart Line Module | 251 A |
| Base-Load Current IL DC with Active Line Module | 226 A |
| Base-Load Current IH DC with Basic/Smart Line Module | 229 A |
| Base-Load Current IH DC with Active Line Module | 206 A |
| Electronics Power Supply | 24 V DC, −15%/+20% |
| Maximum Electronics Current Demand | 0.90 A |
| Current Consumption at 500 V AC | 1.50 A |
| Current Consumption at 690 V AC | 1.00 A |
| Rated Pulse Frequency | 1.25 kHz |
| Maximum Pulse Frequency | 7.50 kHz |
| Output Frequency Range | 0–550 Hz for servo, V/f and vector control |
| DC-Link Capacitance | 2,800 µF |
| Cooling Method | Forced air cooling using an integrated fan |
| Cooling Air Requirement | 0.36 m³/s |
| Operating Temperature | 0–40°C |
| Installation Altitude Without Derating | Up to 2,000 m |
| Motor-Side Connection | 2 × M10 screw connections |
| Motor-Side Conductor Capacity | 2 × 240 mm² |
| DC-Link Connection | 2 × M10 screw connections |
| DC-Link Conductor Capacity | 2 × 240 mm² |
| Braking Module Connection | M6 bolt |
| PE1 Connection | 2 × M10 screw connections, 2 × 240 mm² |
| PE2 Connection | 2 × M10 screw connections, 2 × 240 mm² |
| Maximum Shielded Motor Cable Length | 300 m |
| Maximum Unshielded Motor Cable Length | 450 m |
| Degree of Protection | IP20 |
| Width | 326 mm |
| Height | 1,533 mm |
| Depth | 545 mm |
| Net Weight | 136 kg |
| Sound Pressure Level | 69 dB at 50 Hz; 73 dB at 60 Hz |
| Maximum Power Loss at 50 Hz, 690 V | 3.09 kW |
| Maximum Power Loss at 60 Hz, 575 V | 2.91 kW |
| Compliance | CE and RCM |
| Part Description | Siemens chassis-format motor module engineered for controlling high-power industrial motors, providing up to 200 kW type rating, a 215 A rated output and forced-air cooling for integration into large drive systems. |
This is a high-power motor module designed to regulate the electrical output supplied to an industrial AC motor. It is intended for use within a compatible SINAMICS low-voltage drive configuration.
The type rating is 200 kW based on the rated output current, or 160 kW based on the high-overload duty rating. These values relate to a typical six-pole standard induction motor under the specified operating conditions.
The rated output current is 215 A. The base-load current is 208 A for low-overload duty and 192 A for high-overload duty, while the maximum stated current is 312 A.
The specified DC-link voltage range is 675 to 1,035 V DC. Compatibility with the wider drive configuration should be checked before installation.
The electronics require a nominal 24 V DC supply with a tolerance of -15% to +20%. Maximum current demand is 0.90 A.
The module is rated for servo, V/f and vector control applications. For each method, the stated output-frequency range is 0 to 550 Hz.
The rated pulse frequency is 1.25 kHz, while the stated maximum is 7.50 kHz. Available output current and maximum output frequency can vary with the selected pulse frequency.
The unit uses forced-air cooling through integrated fans. Its specified cooling-air requirement is 0.36 cubic metres per second, so adequate cabinet ventilation and airflow must be included in the installation design.
The specified operating temperature range is 0°C to 40°C. Conditions outside this range may require additional engineering assessment or power derating.
The chassis measures 326 mm wide, 1,533 mm high and 545 mm deep. Its net weight is approximately 136 kg, so the enclosure and mounting arrangement must accommodate both its size and mass.
The module has an IP20 protection rating and a chassis-style construction. It is therefore intended for installation within a suitable industrial cabinet or protected electrical area.
The motor, DC-link, PE1 and PE2 connections each use two M10 screw connections and accept conductor cross-sections up to 2 x 240 mm². The braking-module connection uses an M6 bolt.
The stated maximum is 300 metres for shielded cable and 450 metres for unshielded cable. These figures refer to the combined length of the motor cables and DC-link connections within the configuration.
Siemens 6SL3320-1TG32-2AA3 is rated for installation at altitudes up to 2,000 metres without derating. Installations above this level require consideration of reduced cooling performance and electrical clearances.
For low-overload duty, the 208 A base-load rating allows 110% for 60 seconds or 150% for 10 seconds within a 300-second cycle. For high-overload duty, the 192 A rating allows 150% for 60 seconds or 160% for 10 seconds within the same cycle.
The specified DC-link capacitance is 2,800 µF. This forms part of the module's internal power-stage design and should be considered when assessing the complete DC-link configuration.
The stated maximum power loss is 3.09 kW at 50 Hz and 690 V, or 2.91 kW at 60 Hz and 575 V. These figures can be used when calculating cabinet ventilation and heat dissipation requirements.
The specified sound-pressure level at a distance of one metre is 69 dB at 50 Hz and 73 dB at 60 Hz. Actual noise levels may vary with loading, airflow and the surrounding enclosure.
This content has been produced using multiple sources. EU Automation takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
All parts new or reconditioned are covered by EU Automation 12 month warranty
No hassle returns policy
Dedicated customer support team
We understand that credit is a necessary part of business and offer credit agreements on request, subject to status.
Payment optionsWe accept Bank transfers and the following methods of payment:
All transactions are handled securely by HSBC and HSBC Merchant Services. For more information, please visit our dedicated payments page.
Global supplier of quality automation and control components
Dispose of your old unit by exchanging it for a working part.
A comprehensive repair service for faulty equipment.
You don’t need tights and a cape to be a hero.
Get parts fast and feel like a legend, just like Jeff.