steve
Got hold of Sime for a Carrier card for…
Got hold of Sime for a Carrier card for a chiller. Machine down in a factory. Received the new card in express time machine and plant now up and running fantastic service form Sime
3 months ago
Full 12-month warranty
Available for dispatch immediately
We deliver worldwide
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
All orders are subject to product availability. See our T&Cs.
Ask our team
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
| Specification | Description |
|---|---|
| Manufacturer | Siemens |
| Part Number | 3VL2712-1DC33-0AA0 |
| Alternative Part Number | 3VL27121DC330AA0 |
| Product Type | Molded-case circuit breaker |
| Series | VL160N |
| Frame Size | 3VL2 |
| Application | Electrical system and line protection |
| Number of Poles | 3 |
| Rated Current | 125 A |
| Adjustable Overload Current | 100–125 A |
| Instantaneous Short-Circuit Trip Range | 625–1,250 A |
| Overcurrent Release | Thermal-magnetic (TM) |
| Protective Function | LI |
| Overload Protection | Adjustable thermal trip |
| Maximum Rated Operational Voltage | 690 V AC |
| Maximum DC Operating Voltage | 500 V DC |
| Rated Insulation Voltage | 800 V |
| Rated Impulse Withstand Voltage | 8 kV |
| Operating Frequency | 50/60 Hz |
| Ultimate Breaking Capacity at 415 V AC | 55 kA |
| Performance Class | N, standard breaking capacity |
| Utilization Category | Category A |
| Mounting Type | Fixed mounting |
| Main Connection Type | Front-mounted box terminals |
| Main Conductor Capacity | 2.5–95 mm² solid or stranded |
| Flexible Main Conductor Capacity | 2.5–50 mm² with end terminals |
| Flexible Busbar Capacity | 12 × 10 mm |
| Degree of Protection | IP20 |
| Typical Electrical Endurance | 10,000 switching cycles |
| Typical Mechanical Endurance | 20,000 switching cycles |
| Maximum Power Loss | 48 W |
| Operating Temperature | 0 to 70°C |
| Storage Temperature | -40 to 80°C |
| Dimensions | 174.5 mm H × 104.5 mm W × 106.5 mm D |
| Auxiliary Contacts | None included |
| Motor Operator Compatibility | Optional motor operator can be fitted |
| Commodity Code | 85362090 |
This is a molded case circuit breaker designed for system and line protection in industrial low-voltage electrical installations.
The circuit breaker has three poles, allowing it to protect and switch all three phases of a three-phase circuit.
The Siemens 3VL2712-1DC33-0AA0 has a rated continuous current of 125 A. Its thermal overload pickup can be adjusted from 100 A to 125 A.
Its ultimate short-circuit breaking capacity, or Icu, is 55 kA at 415 V AC.
It uses a thermal-magnetic overcurrent release with LI protection. This provides adjustable overload protection and instantaneous short-circuit protection.
The instantaneous short-circuit trip setting can be adjusted between 625 A and 1,250 A.
The maximum rated operational voltage is 690 V AC at 50 or 60 Hz. The specified maximum DC operating voltage is 500 V.
Yes. It uses a fixed-mounting design with front-facing box terminals for the main electrical connections.
The main terminals accept solid or stranded conductors from 2.5 to 95 mm². Finely stranded conductors with prepared ends can range from 2.5 to 50 mm².
The circuit breaker measures approximately 174.5 mm high, 104.5 mm wide, and 106.5 mm deep.
The specified operating temperature range is 0°C to 70°C. Current derating applies above 50°C, with a rated operating current of 116.3 A at 55°C to 60°C and 107.5 A at 65°C to 70°C.
The circuit breaker has an IP20 protection rating.
No. This configuration does not include auxiliary contacts, an auxiliary switch, a voltage release, an undervoltage release, or a trip indicator.
Yes. Although a motor drive is not included in the standard configuration, the design supports an optional motor operator.
The specified typical endurance is 10,000 electrical switching cycles and 20,000 mechanical switching cycles.
No. This model provides overload and short-circuit protection but does not include ground-fault protection.
The breaker belongs to the Siemens 3VL2 frame size and uses the VL160N standard breaking-capacity class.
Confirm the three-pole arrangement, 125 A rating, 100–125 A overload adjustment range, 625–1,250 A instantaneous trip range, 55 kA breaking capacity at 415 V AC, fixed mounting, terminal format, dimensions, and required accessories.
This content has been produced using multiple sources. EU Automation takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
All parts new or reconditioned are covered by EU Automation 12 month warranty
No hassle returns policy
Dedicated customer support team
We understand that credit is a necessary part of business and offer credit agreements on request, subject to status.
Payment optionsWe accept Bank transfers and the following methods of payment:
All transactions are handled securely by HSBC and HSBC Merchant Services. For more information, please visit our dedicated payments page.
Global supplier of quality automation and control components
Dispose of your old unit by exchanging it for a working part.
A comprehensive repair service for faulty equipment.
You don’t need tights and a cape to be a hero.
Get parts fast and feel like a legend, just like Jeff.