steve
Got hold of Sime for a Carrier card for…
Got hold of Sime for a Carrier card for a chiller. Machine down in a factory. Received the new card in express time machine and plant now up and running fantastic service form Sime
3 months ago
Full 12-month warranty
Available for dispatch immediately
We deliver worldwide
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
All orders are subject to product availability. See our T&Cs.
Ask our team
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
| Specification | Description |
|---|---|
| Manufacturer | Siemens |
| Part Number | 3RW3014-1BB04 |
| Alternative Part Number | 3RW30141BB04 |
| Product Type | Soft starter (for standard motor starting applications) |
| Product Range / Series | SIRIUS |
| Device Size | S00 |
| Rated Operational Current (Ie) @ 40 °C | 6.5 A |
| Rated Operational Current (Ie) @ 50 °C | 6 A |
| Rated Operational Current (Ie) @ 60 °C | 5.5 A |
| Motor Power Rating @ 400 V (standard circuit) | 3 kW (at 40 °C) |
| Motor Power Rating @ 230 V (standard circuit) | 1.5 kW (at 40 °C) |
| Motor Output (UL/CSA reference) @ 200/208 V | 1 hp (at 50 °C, standard circuit) |
| Motor Output (UL/CSA reference) @ 220/230 V | 1 hp (at 50 °C, standard circuit) |
| Motor Output (UL/CSA reference) @ 460/480 V | 3 hp (at 50 °C, standard circuit) |
| Operating Voltage (main circuit, standard circuit) | 200…480 V AC |
| Operating Frequency | 50…60 Hz |
| Integrated Bypass Contact System | Yes |
| Power Semiconductor Technology | Thyristors |
| Control Supply Voltage Type | AC/DC |
| Control Supply Voltage | 24 V AC/DC |
| Typical Power Loss During Operation | 0.5 W (typical, at 40 °C) |
| Minimum Load | 10% of motor current (Iₘ) |
| Insulation Voltage (Ui) | 600 V |
| Thyristor Blocking Voltage (max.) | 1200 V |
| Pollution Degree | 3 (to IEC 60947-4-2) |
| Intrinsic Device Protection | No |
| Motor Overload Protection | No |
| Thermistor Motor Protection Evaluation | No |
| External Reset | No |
| Adjustable Current Limitation | No |
| Inside-Delta Circuit | No |
| Motor Brake Output | No |
| Auxiliary Contacts | 1 x NO |
| Auxiliary Contact Rating (UL designation) | B300 / R300 |
| Connection Type (main circuit) | Screw-type terminals |
| Connection Type (control/auxiliary) | Screw-type terminals |
| Main Conductor Cross-Section (solid) | 2 x (1…2.5 mm²) or 2 x (2.5…6 mm²) |
| Main Conductor Cross-Section (finely stranded with end processing) | 2 x (1.5…2.5 mm²) or 2 x (2.5…6 mm²) |
| Main Conductor Size (AWG) | 2 x (16…10 AWG) |
| Auxiliary Conductor Cross-Section (solid) | 2 x (0.25…2.5 mm²) |
| Auxiliary Conductor Cross-Section (finely stranded with end processing) | 2 x (0.25…1.5 mm²) |
| Auxiliary Conductor Size (AWG) | 2 x (20…14 AWG); finely stranded with end processing: 2 x (20…16 AWG) |
| Mounting Method | Screw and snap-on mounting |
| Mounting Orientation Tolerance | Vertical mounting surface ±10° rotatable; ±10° tilt forwards/backwards |
| Required Spacing (side-by-side mounting) | Upwards: 60 mm; Side: 15 mm; Downwards: 40 mm |
| Maximum Cable Length | 300 m |
| Number of Poles (main current circuit) | 3 |
| Ambient Temperature (operation) | -25…+60 °C |
| Ambient Temperature (storage) | -40…+80 °C |
| Derating Temperature | 40 °C |
| Installation Altitude (max.) | 5000 m above sea level |
| Front Protection Class | IP20 |
| Fault Indication | Red indicator |
| Dimensions (W x H x D) | 45 mm x 95 mm x 150 mm |
| Reference Code (EN 61346-2) | Q |
| Reference Code (DIN 40719 / IEC) | G |
| Part Description | Compact Siemens SIRIUS soft starter, size S00, designed to reduce inrush current and mechanical stress during the start-up of three-phase motors. Rated 6.5 A with 200–480 V AC main circuit and 24 V AC/DC control supply, featuring an integrated bypass contact system and screw terminals for straightforward panel installation. |
It reduces the inrush current and mechanical shock during motor start by ramping up the applied voltage using thyristors. This helps limit voltage dips and reduces stress on couplings, belts and gearboxes compared with direct-on-line starting.
It is typically used for smaller three-phase motors, up to around 3 kW at 400 V in a standard circuit at 40 °C, with an operational current rating of 6.5 A at 40 °C.
The main circuit operating voltage range is 200 to 480 V AC (50/60 Hz), suitable for many common three-phase industrial supplies.
The control electronics use 24 V AC/DC. This is separate from the motor supply and is used for the control inputs and internal electronics.
Yes. It includes an integrated bypass contact system, allowing the current to be carried by bypass contacts after ramp-up to reduce heat generation in steady operation.
No. Motor overload protection is not included, so an appropriate external overload protection method should be used where required by the application.
This model is intended for soft starting for standard applications. If your application needs controlled deceleration (for example to reduce water hammer in pumping), you should confirm the required stop behaviour at the system level.
No. Adjustable current limitation is not available on this model.
No. An inside-delta circuit option is not provided on this unit; it is designed for standard in-line soft starter connection.
It provides 1 normally open (NO) auxiliary contact and no normally closed (NC) or changeover auxiliary contacts.
It uses screw-type terminals for both the main current circuit and the auxiliary/control circuit.
The front is rated IP20 and is finger-safe for vertical contact from the front when installed correctly within a suitable panel or enclosure.
Typical ambient temperature range during operation is -25 °C to +60 °C, with derating starting at 40 °C depending on installation conditions.
For side-by-side mounting, typical spacing guidance is 60 mm above, 15 mm to the side, and 40 mm below to help maintain airflow and thermal performance.
Approximate dimensions are 45 mm (width) x 95 mm (height) x 150 mm (depth), corresponding to size S00.
Yes. A red fault indication is provided on the device for basic visual signalling.
Installation altitude is specified up to 5,000 m above sea level; however, electrical equipment may require derating depending on temperature and ventilation in the panel.
Typical active power loss during the operating phase at operational current and 40 °C is around 0.5 W, helped by the integrated bypass once running.
It is commonly used to start small three-phase motors on applications such as pumps, fans, conveyors and compressors where reducing starting stress and inrush current is beneficial. For reference, the unit is often supplied as Siemens 3RW3014-1BB04.
This content has been produced using multiple sources. EU Automation takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
All parts new or reconditioned are covered by EU Automation 12 month warranty
No hassle returns policy
Dedicated customer support team
We understand that credit is a necessary part of business and offer credit agreements on request, subject to status.
Payment optionsWe accept Bank transfers and the following methods of payment:
All transactions are handled securely by HSBC and HSBC Merchant Services. For more information, please visit our dedicated payments page.
Global supplier of quality automation and control components
Dispose of your old unit by exchanging it for a working part.
A comprehensive repair service for faulty equipment.
You don’t need tights and a cape to be a hero.
Get parts fast and feel like a legend, just like Jeff.