steve
Got hold of Sime for a Carrier card for…
Got hold of Sime for a Carrier card for a chiller. Machine down in a factory. Received the new card in express time machine and plant now up and running fantastic service form Sime
3 months ago
Full 12-month warranty
Available for dispatch immediately
We deliver worldwide
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
All orders are subject to product availability. See our T&Cs.
Ask our team
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
| Specification | Description |
|---|---|
| Manufacturer | Siemens |
| Part number | 3RT1466-6AF36 |
| Alternative part number | 3RT14666AF36 |
| Product type | Heavy-duty power contactor |
| Series | SIRIUS 3RT14 |
| Product overview | 3-pole contactor designed for demanding switching duties in general automation applications, combining a high AC-1 current rating with an AC/DC operated coil and integrated auxiliary contacts. |
| Contactor size | S10 |
| Number of main poles | 3 |
| Main contact arrangement | 3 NO |
| Auxiliary contact arrangement | 2 NO + 2 NC |
| Rated operational current AC-1 | 400 A up to 690 V at 40 °C ambient |
| Rated operational current AC-1 at elevated temperature | 380 A up to 690 V at 60 °C ambient |
| Rated operational current AC-3 | 138 A at 400 V; 138 A at 690 V |
| Rated insulation voltage | 1,000 V |
| Rated surge withstand voltage | 8 kV main circuit; 6 kV auxiliary circuit |
| Control supply voltage | 110 to 127 V AC, 50/60 Hz, or 110 to 127 V DC |
| Coil operating range | 0.8 to 1.1 x rated control voltage for AC and DC operation |
| Surge suppressor | Integrated varistor |
| Pick-up power | 590 VA at AC |
| Holding power | 6.7 VA at AC; 7.4 W at DC |
| Closing delay | 30 to 95 ms |
| Opening delay | 40 to 80 ms |
| Arcing time | 10 to 15 ms |
| Main circuit connection | Busbar / connection bar |
| Auxiliary and control terminal type | Screw terminals |
| Main conductor size | 70 to 240 mm² |
| Main conductor size (AWG) | 2/0 to 500 kcmil |
| Auxiliary conductor size | 0.5 to 4 mm² |
| Auxiliary conductor size with ferrules | 0.5 to 2.5 mm² |
| Connection bar dimensions | 25 mm width, 6 mm thickness |
| Connection hole diameter | 11 mm |
| Mounting method | Screw fixing |
| Mounting position | Suitable for vertical mounting surfaces, with permitted rotation and slight forward/back tilt |
| Dimensions (H x W x D) | 210 x 145 x 202 mm |
| Weight | 6.300 kg |
| Front protection rating | IP00; up to IP20 on the front when fitted with cover / box terminal |
| Pollution degree | 3 |
| Ambient operating temperature | -25 to +60 °C |
| Storage temperature | -55 to +80 °C |
| Maximum installation altitude | 2,000 m above sea level |
| Relative humidity during operation | Up to 95% |
| Mechanical endurance | Typical mechanical life of 10,000,000 operating cycles |
| No-load switching frequency | Up to 2,000 operations per hour |
| Maximum operating frequency at AC-1 | Up to 600 operations per hour |
| Short-circuit protection for main circuit | Typically coordinated with 500 A gG/gL or gR fuse protection, depending on coordination type |
| Short-circuit protection for auxiliary circuit | Typically 10 A gG fuse protection |
| Standards-related contact feature | Mirror contact function in accordance with IEC 60947-4-1 |
| Commodity code | 853649 |
| Part category | General Automation |
This is a 3-pole power contactor designed for switching high-current loads in general automation and industrial power circuits. It is suited to applications where dependable switching of substantial AC loads is required.
It is commonly used in larger motor and power switching duties, including control panels, distribution assemblies, industrial machinery, HVAC equipment and other heavy-duty automation systems where a high-capacity contactor is needed.
It has 3 main poles with 3 normally open main contacts, making it suitable for three-phase switching applications.
This unit is rated at 400 A in AC-1 duty up to 690 V at 40 °C ambient temperature. For AC-3 duty, the rated current is 138 A at 400 V, which is useful when considering motor-related switching duties.
The control supply voltage is 110 to 127 V AC at 50/60 Hz or 110 to 127 V DC. That gives flexibility where either AC or DC control circuits are used.
Yes. The coil is designed for AC/DC operation across the 110 to 127 V range, so it can be integrated into either type of control scheme where the specified voltage is available.
Yes. The contactor includes 2 normally open and 2 normally closed auxiliary contacts as standard, which can be useful for interlocking, signalling and control logic.
Yes. This version includes a varistor as the surge suppressor, helping to manage switching transients on the control side.
The main current circuit uses bar or busbar-style connections, while the auxiliary and control circuits use screw-type terminals. This arrangement suits high-current installations with conventional panel wiring practices.
For the main contacts, the connectable conductor cross-section is 70 to 240 mm², with AWG compatibility from 2/0 to 500 kcmil. For the auxiliary contacts, the typical range is 0.5 to 4 mm², depending on conductor type.
The contactor is approximately 210 mm high, 145 mm wide and 202 mm deep. Its listed weight is 6.3 kg, so panel layout and mounting strength should be considered during design.
Yes. Side-by-side mounting is supported. Clearance requirements still need to be observed, including forward, upward, downward and side spacing depending on surrounding grounded or live parts.
The front is rated IP00 as standard, with IP20 on the front when used with a cover or box terminal arrangement. The terminals themselves are rated IP00.
It is intended for operation in ambient temperatures from -25 °C to +60 °C, with storage down to -55 °C and up to +80 °C. The maximum installation altitude is 2,000 m above sea level.
The typical mechanical service life is up to 10,000,000 operating cycles, which makes it a strong option for demanding industrial switching applications.
No. The contactor itself does not provide short-circuit protection, so suitable upstream protective devices must be selected as part of the overall panel design.
It is designed for screw fixing on a vertical mounting surface. The specified mounting arrangement also allows for some rotational and tilt tolerance during installation.
Yes. With its S10 frame size, 400 A AC-1 rating, busbar main connections and built-in auxiliary contacts, the 3RT1466-6AF36 is well suited to substantial panel-based switching duties where a robust conventional contactor is required.
This content has been produced using multiple sources. EU Automation takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
All parts new or reconditioned are covered by EU Automation 12 month warranty
No hassle returns policy
Dedicated customer support team
We understand that credit is a necessary part of business and offer credit agreements on request, subject to status.
Payment optionsWe accept Bank transfers and the following methods of payment:
All transactions are handled securely by HSBC and HSBC Merchant Services. For more information, please visit our dedicated payments page.
Global supplier of quality automation and control components
Dispose of your old unit by exchanging it for a working part.
A comprehensive repair service for faulty equipment.
You don’t need tights and a cape to be a hero.
Get parts fast and feel like a legend, just like Jeff.