steve
Got hold of Sime for a Carrier card for…
Got hold of Sime for a Carrier card for a chiller. Machine down in a factory. Received the new card in express time machine and plant now up and running fantastic service form Sime
3 months ago
Full 12-month warranty
Available for dispatch immediately
We deliver worldwide
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
All orders are subject to product availability. See our T&Cs.
Ask our team
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
| Specification | Description |
|---|---|
| Manufacturer | Siemens |
| Part Number | 3RT1034-3AG20 |
| Alternative Part Number | 3RT10343AG20 |
| Product Type | Power contactor |
| Product Range | SIRIUS |
| Contactor Size | S2 |
| Main Circuit Poles | 3-pole |
| Main Contacts | 3 NO (normally open) |
| Rated Insulation Voltage (Ui) | 690 V |
| Rated Impulse Withstand Voltage (Uimp) | 6 kV |
| Pollution Degree | 3 |
| Control Supply Type | AC |
| Coil Rated Voltage | 110 V AC (50/60 Hz) |
| Coil Operating Range (50 Hz) | 0.8 … 1.1 × rated coil voltage |
| Coil Operating Range (60 Hz) | 0.85 … 1.1 × rated coil voltage |
| Coil Pick-up Apparent Power | 127 VA |
| Coil Holding Apparent Power | 11.3 VA |
| Main Circuit Rating (AC-3) | 32 A at 400 V |
| Motor Rating (AC-3) | 15 kW at 400 V |
| Main Circuit Rating (AC-1) | 50 A at 400 V (40 °C) |
| Main Circuit Rating (AC-3) at 690 V | 20 A |
| Main Circuit Rating (AC-4) | 29 A at 400 V |
| Thermal Short-time Current (10 s) | 320 A |
| No-load Switching Frequency (AC) | 5,000 operations/hour |
| Max Operating Frequency (AC-3) | 1,000 operations/hour |
| Closing Delay (AC) | 11 … 30 ms |
| Opening Delay (AC) | 7 … 20 ms |
| Arcing Time | 10 … 15 ms |
| Mechanical Service Life | Typical 10,000,000 switching cycles |
| Protection Class (front) | IP20 |
| Protection Class (terminal) | IP00 |
| Max Installation Altitude | 2,000 m |
| Ambient Temperature (operation) | -25 … +60 °C |
| Ambient Temperature (storage) | -55 … +80 °C |
| Mounting Method | Screw mounting and snap-on mounting on 35 mm DIN rail (DIN EN 50022) |
| Side-by-side Mounting | Yes |
| Connection Type (main circuit) | Screw-type terminals |
| Connection Type (aux/control circuit) | Spring-loaded terminals |
| Main Terminal Conductor Size (solid) | 2 × (0.75 … 16 mm²) |
| Main Terminal Conductor Size (stranded) | 2 × (0.75 … 25 mm²) |
| Main Terminal Conductor Size (fine-stranded, with ferrule) | 2 × (0.75 … 16 mm²) |
| Main Terminal AWG Range | 2 × (18 … 2 AWG) |
| Aux Terminal Conductor Size (solid) | 2 × (0.25 … 2.5 mm²) |
| Aux Terminal Conductor Size (fine-stranded, with ferrule) | 2 × (0.25 … 1.5 mm²) |
| Aux Terminal AWG Range | 2 × (24 … 14 AWG) |
| Recommended Fuse (main circuit, coordination type 1) | gL/gG 125 A |
| Recommended Fuse (main circuit, coordination type 2) | gL/gG 63 A |
| Recommended Fuse (aux circuit) | gL/gG 10 A |
| Dimensions (H × W × D) | 112 × 55 × 115 mm |
| Product Description | Siemens SIRIUS 3RT1034-3AG20 is a 3-pole power contactor in size S2, designed for reliable switching of three-phase loads, with an AC coil rated at 110 V (50/60 Hz) and performance suited to motor switching up to 15 kW at 400 V (AC-3). |
It is an electromechanical switching device designed to repeatedly switch power to loads such as three-phase motors or resistive loads. The coil is energised by a control voltage, which closes the main power contacts to feed the load.
It is rated for common IEC utilisation categories including AC-3 (motor duty) and AC-1 (resistive/low-inductive duty). Typical ratings include AC-3: 32 A at 400 V and 15 kW at 400 V, and AC-1: 50 A at 400 V (also 50 A up to 690 V at 40 °C).
The control coil is 110 V AC and is suitable for both 50 Hz and 60 Hz operation.
No. This variant is specified with an AC coil (110 V AC, 50/60 Hz). If your control circuit is DC, you would need a version with a DC coil.
It is a 3-pole contactor, providing three normally-open main contacts for three-phase switching.
No auxiliary contacts are integrated as standard (0 NO and 0 NC instantaneous auxiliary contacts). If auxiliary signalling is required, an add-on auxiliary contact block is typically used.
The rated insulation voltage is 690 V, and the rated surge voltage resistance is 6 kV.
For IEC AC-3 motor duty, typical operating current is 32 A at 400 V and 20 A at 690 V. For more severe AC-4 duty at 400 V, the rating is 29 A.
It supports screw mounting and snap-on mounting onto a 35 mm standard mounting rail (DIN EN 50022). Side-by-side mounting is permitted.
Approximate dimensions are 112 mm (H) × 55 mm (W) × 115 mm (D).
The front is rated IP20. The terminals are rated IP00.
Typical operating ambient temperature range is -25 to +60 °C, and storage temperature range is -55 to +80 °C. Maximum installation altitude is 2,000 m above sea level.
The main power circuit uses screw-type terminals. The auxiliary/control circuit uses spring-loaded terminals.
Typical connectable conductor cross-sections for main contacts include solid: 2× (0.75 to 16 mm²) and stranded: 2× (0.75 to 25 mm²). AWG range is typically 2× (18 to 2).
Typical connectable conductor cross-sections for auxiliary/control terminals include solid: 2× (0.25 to 2.5 mm²) and finely stranded with core end processing: 2× (0.25 to 1.5 mm²). AWG range is typically 2× (24 to 14).
Typical closing delay is 11 to 30 ms, opening delay is 7 to 20 ms, and arcing time is 10 to 15 ms (AC coil operation).
Typical apparent pick-up power is 127 VA and apparent holding power is 11.3 VA for the AC coil.
Typical maximum operating frequencies include AC-1 up to 1,200 operations/hour, AC-3 up to 1,000 operations/hour, and AC-4 up to 250 operations/hour. No-load switching frequency is typically up to 5,000 operations/hour (AC).
Typical guidance for short-circuit protection of the main circuit specifies gL/gG fuses of 125 A for coordination type 1 and 63 A for coordination type 2.
Typical mechanical service life is 10,000,000 switching cycles for the contactor. With an added electronics-compatible auxiliary switch block, typical life is 5,000,000 cycles.
Yes, for IEC AC-3 duty it is typically rated 15 kW at 400 V (with an AC-3 operating current of 32 A at 400 V). For reference, this is the Siemens SIRIUS power contactor 3RT1034-3AG20 variant with a 110 V AC coil.
This content has been produced using multiple sources. EU Automation takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
All parts new or reconditioned are covered by EU Automation 12 month warranty
No hassle returns policy
Dedicated customer support team
We understand that credit is a necessary part of business and offer credit agreements on request, subject to status.
Payment optionsWe accept Bank transfers and the following methods of payment:
All transactions are handled securely by HSBC and HSBC Merchant Services. For more information, please visit our dedicated payments page.
Global supplier of quality automation and control components
Dispose of your old unit by exchanging it for a working part.
A comprehensive repair service for faulty equipment.
You don’t need tights and a cape to be a hero.
Get parts fast and feel like a legend, just like Jeff.