3RF2430-1AC45

Siemens 3RF2430-1AC45 available at EU Automation. Get in touch today for a quick price.

Trustpilot stars Based on over 4900 reviews

Full 12-month warranty

Available for dispatch immediately

We deliver worldwide

Get a quick price for 3RF2430-1AC45

Quantity

Adding another part to your enquiry?

For more information on how your data is processed and stored by EU Automation please read our privacy policy.

All orders are subject to product availability. See our T&Cs.

Ask our team

What happens next?

1. Email confirmation

You will get an email confirming that we have received your enquiry.

2. Dedicated Account Manager

One of our team will be in touch to confirm your part(s) specification and condition.

3. Your quote

You will receive a comprehensive quote tailored to your specific needs.

Siemens 3RF2430-1AC45 is a SIRIUS three-phase solid-state contactor designed for reliable switching of AC loads with zero-cross (zero-point) switching to help reduce electrical noise and inrush-related stress. It provides a 3-pole, 3NO main current path rated up to 30 A (AC-51) at 40 °C, with an operating voltage range of 48–600 VAC at 50/60 Hz (operating range up to 40–660 VAC). The control input is 4–30 VDC, making it well suited for PLC and low-voltage control architectures; typical control current is 22 mA at minimum control voltage and 30 mA at the DC rated value.

Built for panel integration, the 3RF2430-1AC45 features screw-type terminals for both main and control connections, an IP20 front protection rating, and compact dimensions of approximately 100 mm (H) × 89.5 mm (W) × 128 mm (D). It supports side-by-side mounting and accepts a broad range of conductor sizes, including 1.5–6 mm² for main power wiring (up to 10 mm² with ferrules) and 0.5–2.5 mm² for control wiring. This solid-state design is a strong choice for applications requiring frequent switching, long service intervals, and consistent performance in industrial environments across an ambient operating range of -25 to +60 °C.
Specification Description
Manufacturer Siemens
Manufacturer Part Number (MPN) 3RF2430-1AC45
Alternative Part Number 3RF24301AC45
Product Series SIRIUS 3RF2
Product Type Solid-state contactor
Part Description Three-phase, three-pole solid-state contactor with zero-cross (zero-point) switching for smooth AC load control, featuring 4–30 VDC control input and screw terminals for panel or DIN-rail mounting.
Main Circuit Configuration 3-pole, 3 NO (normally open)
Auxiliary Contacts None (0 NO / 0 NC / 0 CO)
Load Type / Utilization Category AC-51
Rated Operational Current 30 A (AC-51)
IEC 60947-4-3 Current Rating 22 A (AC-51)
UL 508 Current Rating 22 A
Minimum Load Current 0.5 A (500 mA)
Rated Operating Voltage (Main Circuit) 48…600 VAC, 50/60 Hz
Operating Voltage Range (Main Circuit) 40…660 VAC, 50/60 Hz
Rated Operating Frequency 50…60 Hz
Frequency Tolerance (Main Circuit) ±10% (relative symmetrical tolerance)
Control Supply Voltage Type DC
Control Supply Voltage Range 4…30 VDC
Control Signal Thresholds Signal “1” detection starts at 4 VDC; signal “0” recognition at 1 VDC
Control Current 22 mA at minimum control voltage; 30 mA at rated value
Turn-ON Delay Time 1 ms, plus up to one half-wave
Switching Function Zero-cross switching
Rated Insulation Voltage (Ui) 600 V
Surge Voltage Withstand (Main Circuit) 6 kV
Thyristor Blocking Voltage (Max) 1200 V
Max Rate of Rise of Off-State Voltage (dv/dt) 1000 V/µs
Reverse Current of Thyristor 10 mA
Surge Current Capability 1200 A
I²t Value (Max) 7200 A²·s
Derating Reference Temperature 40 °C
Power Loss (Rated Current, Hot State) 91 W total (30.33 W per pole)
Power Loss (Typical, No Load Current Share) 0.9 W
Degree of Pollution 3
Front Protection Rating IP20
Touch Protection (Front) Finger-safe (front, vertical contact)
Operating Ambient Temperature -25…+60 °C
Storage Ambient Temperature -55…+80 °C
Maximum Installation Altitude 1000 m
Vibration Resistance 2 g (IEC 60068-2-6)
Shock Resistance 15 g / 11 ms (IEC 60068-2-27)
Mounting Screw fixing; snap-on mounting on 35 mm DIN rail (IEC 60715)
Side-by-Side Mounting Yes
Electrical Connections (Main / Control) Screw-type terminals (main circuit and control circuit)
Removable Terminal (Control Circuit) Yes
Main Terminal Screw Thread M4
Control Terminal Screw Thread M3
Tightening Torque (Main Terminals) 2.0…2.5 N·m
Tightening Torque (Control Terminals) 0.5…0.6 N·m
Strip Length (Main / Control) 7 mm / 7 mm
Connectable Conductor Size (Main, Solid/Stranded) 1.5…6 mm²
Connectable Conductor Size (Main, Fine-Stranded with Ferrule) 1…10 mm²
AWG Range (Main) 14…10 AWG
Connectable Conductor Size (Control, Solid) 0.5…2.5 mm² (also 2x 0.5…1.0 mm²)
Connectable Conductor Size (Control, Fine-Stranded) 0.5…2.5 mm² (also 2x 0.5…1.0 mm²)
AWG Range (Control) 20…12 AWG
Dimensions (H × W × D) 100 mm × 89.5 mm × 128 mm
Weight 0.56 kg
Reference Code (IEC 81346-2) Q
Compatible Accessory (Converter) 3RF2900-0EA18

What type of device is this and what does it do?

It is a three-phase solid-state contactor designed to switch AC loads electronically (no mechanical main contacts). It is typically used to turn three-phase heaters or other resistive loads on and off with fast, quiet operation.

How many poles and main switching contacts does it have?

It has 3 poles and 3 normally open (NO) semiconductor switching paths for the main current circuit (3NO).

What load voltage and frequency range can it switch?

The rated operating voltage is 48 to 600 V AC at 50/60 Hz. The operating range relative to the operating voltage is 40 to 660 V AC (50/60 Hz), as specified for the main circuit.

What is the control input type and control voltage range?

The control supply is DC, with a control voltage range of 4 to 30 V DC (maximum permissible rated value 30 V DC).

Does it use zero-cross switching or instantaneous switching?

It is designed for zero-point (zero-cross) switching, which helps reduce inrush and electrical noise when switching suitable AC loads.

What is the rated current and how should it be interpreted?

The operational current is rated at 30 A (AC-51) at a derating temperature of 40 °C. It is also stated as 22 A according to IEC 60947-4-3 and 22 A according to UL 508; selection should match the applicable standard and installation conditions.

Is there a minimum load current requirement?

Yes. The specified minimum operational current is 500 mA, which can be important when switching very small loads.

What are the key semiconductor electrical limits (blocking voltage and dv/dt)?

The maximum permissible blocking voltage at the thyristor for the main contacts is 1200 V, and the maximum permissible rate of voltage rise (dv/dt) is 1000 V/µs.

How quickly does it turn on after a control signal is applied?

The switch-on delay time is specified as 1 ms, plus up to a maximum of one half-wave due to the zero-cross switching function.

What mounting options are supported?

It supports screw fixing and snap-on mounting on a 35 mm standard mounting rail (IEC 60715). Side-by-side mounting is permitted.

What are the overall dimensions and approximate weight?

The typical dimensions are 100 mm (H) x 89.5 mm (W) x 128 mm (D), and the weight is approximately 0.56 kg.

What ingress protection rating does it have?

It is rated IP20 on the front, intended for installation inside an enclosure or control panel.

What wire sizes and terminal types are used for the main and control connections?

Both main and control circuits use screw-type terminals. Main circuit conductors: solid/stranded 1.5 to 6 mm², finely stranded with end processing 1 to 10 mm² (AWG 14 to 10). Control circuit conductors: solid 0.5 to 2.5 mm² (and certain 2x 0.5 to 1.0 mm² options), AWG 20 to 12. Typical stripping length is 7 mm.

What tightening torque should be used on the terminals?

Main terminals (M4): 2.0 to 2.5 N·m. Control/auxiliary terminals (M3): 0.5 to 0.6 N·m.

Does it include auxiliary contacts for feedback?

No. It has no auxiliary contacts (0 NO, 0 NC, 0 changeover) listed for the auxiliary circuit; it is focused on solid-state switching of the main three-phase path.

How much heat does it generate and what does that mean for panel design?

Power loss at the rated current (AC, hot operating state) is specified as 91 W total (about 30.33 W per pole). This should be considered for enclosure ventilation, spacing, and thermal management.

What short-circuit protection approach is recommended for semiconductor switching devices like this?

Semiconductor switching devices typically require appropriately selected protective devices to limit fault energy. Siemens lists compatible semiconductor protection fuse links (for example, NH and cylindrical options) and an NH gG fuse option up to 460 V. Selection should be coordinated with the installation’s fault level and applicable standards.

What ambient conditions is it designed to operate in?

Operating ambient temperature is -25 to +60 °C, storage temperature is -55 to +80 °C, and the maximum installation altitude is 1000 m above sea level.

Is it suitable for industrial EMC environments?

It is specified with conducted and radiated EMC performance for industrial environments (including emissions classification per CISPR 11 Class A), which is typical for industrial control panel applications.

What are the control terminal polarities shown for the DC input?

The control terminals are labeled A1 as positive (+) and A2 as negative (-) for the DC control input, as shown in the device’s terminal diagram for the Siemens 3RF2430-1AC45.

  • Switching three-phase resistive loads in industrial panels using solid-state, zero-cross operation to reduce electrical noise
  • Controlling heating circuits such as ovens, furnaces, hot plates, and infrared heater banks where frequent cycling is required
  • On/off control of electric process heaters in plastics, packaging, and food-processing equipment
  • Switching three-phase lighting and thermal loads in test rigs, burn-in stations, and production lines
  • High-duty-cycle control of industrial power circuits where silent operation and no mechanical wear are preferred
  • Interface switching from low-voltage DC control outputs (4–30 V DC) to higher-voltage three-phase AC loads (48–600 V AC)
  • Contactor replacement in applications where contact bounce or arcing from mechanical devices causes nuisance issues on resistive loads
  • Segmenting and staging multi-zone heater systems by independently switching multiple three-phase heater groups
  • Use in control cabinets with side-by-side mounting where compact, screw-terminal power connections are required
  • Switching three-phase resistive loads in environmental chambers, drying cabinets, and heat-treatment equipment

This content has been produced using multiple sources. EU Automation takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.

Delivery

  • Logistic partners UPS, FedEx and DHL
  • International delivery available
  • Premium nine hour delivery service available to anywhere in Europe
  • Same day dispatch from group stock

Warranty

All parts new or reconditioned are covered by EU Automation 12 month warranty

Returns

No hassle returns policy

Dedicated customer support team

Trade Credit

We understand that credit is a necessary part of business and offer credit agreements on request, subject to status.

Payment options

We accept Bank transfers and the following methods of payment:

All transactions are handled securely by HSBC and HSBC Merchant Services. For more information, please visit our dedicated payments page.

Services

Sourcing your part

Global supplier of quality automation and control components

Service Exchange

Dispose of your old unit by exchanging it for a working part.

Repair

A comprehensive repair service for faulty equipment.

Customer reviews

5 out of 5 stars steve

Got hold of Sime for a Carrier card for…


Got hold of Sime for a Carrier card for a chiller. Machine down in a factory. Received the new card in express time machine and plant now up and running fantastic service form Sime

3 weeks ago

5 out of 5 stars Daniel

Excellent customer service...


Alex Bailey is my main point of contact at EU Automation...he is extremely friendly, has exceptional customer service skills and always offers great pricing & lead times.

2 months ago

5 out of 5 stars Jerry Schrink

Tom Higgins provided amazing service


Tom Higgins provided great prompt service. I contacted Tom by phone and within 10 minutes there was a quote in my in box. WOW Thank you Tom and Thank you EU Automation!

2 months ago

5 out of 5 stars Paulo Pereira

Excellent service and communication…


Excellent service and communication from Alex Bailey. He truly goes above and beyond to ensure his clients are 100% satisfied. The entire process was seamless, and his attention to detail made a huge difference. Highly recommended for anyone looking for amazing service!

2 months ago

5 out of 5 stars Gary

Tom Higgins did a great job at getting…


Tom Higgins did a great job at getting us the part we needed. He saw a concern with the part a verified before shipping.

3 months ago

5 out of 5 stars Lessle Smith

Thomas Higgins has gone above and…


Thomas Higgins has gone above and beyond to make things happen for my facility. His customer service and knowledge were an asset in helping me with my order and the logistics challenges!

4 months ago

Factory worker carrying automation parts box.

Be a Factory Hero.

Get parts fast.

You don’t need tights and a cape to be a hero.
Get parts fast and feel like a legend, just like Jeff.

Be a Factory Hero

FAQs

View all FAQs

We're here when you need us