steve
Got hold of Sime for a Carrier card for…
Got hold of Sime for a Carrier card for a chiller. Machine down in a factory. Received the new card in express time machine and plant now up and running fantastic service form Sime
2 months ago
Full 12-month warranty
Available for dispatch immediately
We deliver worldwide
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
All orders are subject to product availability. See our T&Cs.
Ask our team
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
| Specification | Description |
|---|---|
| Manufacturer | SICK |
| Part Number | 1099969 |
| Model | RLY3-OSSD300 |
| Series | ReLy |
| Product Type | Safety relay |
| Intended Application | Evaluation unit for safety sensors with OSSD outputs |
| Compatible Sensor Types | Safety sensors with OSSDs |
| Safety Integrity Level | SIL 3 according to IEC 61508 |
| Performance Level | PL e according to ISO 13849-1 |
| Category | Category 4 according to ISO 13849-1 |
| PFHD | 1.0 x 10⁻9 |
| Mission Time | 20 years according to ISO 13849-1 |
| Stop Category | Category 0 according to IEC 60204-1 |
| Functions | Sensor sequence monitoring, restart interlock, automatic reset, manual reset and external device monitoring |
| Connection Type | Front connector with spring terminals |
| Configuration Method | Hard-wired connection setup |
| Display Elements | LED indicators |
| Safety Inputs | 2 safety inputs |
| Reset / EDM Input | 1 input for reset pushbutton or external device monitoring |
| Enabling Current Paths | 3 safe enabling current paths |
| Diagnostic Outputs | 2 application diagnostic outputs, not safe |
| Test Pulse Output | 1 test pulse output, not safe |
| Supply Type | PELV or SELV supply |
| Supply Voltage | 24 V DC, operating range 16.8 V ... 30 V |
| Residual Ripple | ≤ 2.4 V |
| Power Consumption | ≤ 2.5 W DC |
| Input Voltage, HIGH | 24 V DC, operating range 11 V ... 30 V |
| Input Voltage, LOW | 0 V DC, operating range -3 V ... 5 V |
| Input Current | 4 mA ... 6 mA |
| Safety Input Test Pulse Width | ≤ 1 ms |
| Safety Input Test Pulse Rate | ≤ 10 Hz |
| Response Time | 12 ms for opening of enabling current paths |
| Enabling Output Contact Type | Normally open, positively guided contacts |
| Contact Material | Silver alloy with gold flash |
| Switching Voltage | 10 V AC ... 230 V AC or 10 V DC ... 230 V DC |
| Switching Current | 10 mA ... 6 A |
| Total Current | 12 A |
| Mechanical Life | 1 x 10⁷ switching cycles |
| Overvoltage Category | Category III according to EN 60664-1 |
| Rated Impulse Withstand Voltage | 6 kV according to EN 60664-1 |
| Diagnostic Output Type | Push-pull semiconductor output, short-circuit protected |
| Diagnostic Output Voltage, HIGH | ≥ Vs - 3 V |
| Diagnostic Output Voltage, LOW | ≤ 3 V |
| Diagnostic Output Input Current, NPN | ≤ 15 mA |
| Diagnostic Output Current, PNP | ≤ 120 mA |
| Test Pulse Output Type | PNP semiconductor output, short-circuit protected |
| Test Pulse Output Voltage | ≥ Vs - 3 V |
| Test Pulse Width | 2 ms |
| Test Pulse Interval | 40 ms |
| Dimensions | 18 mm x 124.6 mm x 85.5 mm |
| Weight | 150 g |
| Enclosure Rating | IP20 according to IEC 60529 |
| Operating Temperature | -25 °C ... +55 °C |
| Storage Temperature | -25 °C ... +70 °C |
| Air Humidity | ≤ 95%, non-condensing |
| Interference Emission | According to IEC 61000-6-4 |
| Interference Resistance | According to IEC 61326-3-1, IEC 61000-6-2 and IEC 609947-5-1 |
| ECLASS 12.0 | 27371819 |
| ETIM 8.0 | EC001449 |
| UNSPSC | 41113704 |
This device is designed as an evaluation unit for machinery protection systems using safety sensors with OSSD outputs. It helps process signals from compatible protective devices and provides safe enabling contacts for machine control circuits.
It is intended for use with safety sensors that provide OSSD outputs. It has two safety inputs and monitors the signal sequence from connected devices.
The relay operates from a 24 V DC supply, with an allowable range of 16.8 V DC to 30 V DC. The supply should be PELV or SELV.
The RLY3-OSSD300 provides three enabling current paths with positively guided normally open contacts for integration into machine control circuits.
The enabling contacts can switch 10 mA to 6 A, with switching voltages from 10 V AC to 230 V AC or 10 V DC to 230 V DC. The total current rating is 12 A.
Yes. It includes two application diagnostic outputs. These are push-pull semiconductor outputs and are not intended to be used as safe outputs.
The device supports restart interlock functionality and can be configured for automatic or manual reset, depending on how the external circuit is wired.
Yes. It includes an input that can be used for either a reset pushbutton or external device monitoring, often referred to as EDM.
The relay is rated up to SIL 3 according to IEC 61508, Category 4 and PL e according to ISO 13849-1, with a PFHD value of 1.0 x 10^-9.
The specified response time for opening the enabling current paths is 12 ms.
The device measures 18 mm wide, 124.6 mm high and 85.5 mm deep. Its weight is approximately 150 g.
It is designed for operation from -25 °C to +55 °C, with storage from -25 °C to +70 °C. The enclosure rating is IP20, and permissible humidity is up to 95% non-condensing.
This content has been produced using multiple sources. EU Automation takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
All parts new or reconditioned are covered by EU Automation 12 month warranty
No hassle returns policy
Dedicated customer support team
We understand that credit is a necessary part of business and offer credit agreements on request, subject to status.
Payment optionsWe accept Bank transfers and the following methods of payment:
All transactions are handled securely by HSBC and HSBC Merchant Services. For more information, please visit our dedicated payments page.
Global supplier of quality automation and control components
Dispose of your old unit by exchanging it for a working part.
A comprehensive repair service for faulty equipment.
You don’t need tights and a cape to be a hero.
Get parts fast and feel like a legend, just like Jeff.