steve
Got hold of Sime for a Carrier card for…
Got hold of Sime for a Carrier card for a chiller. Machine down in a factory. Received the new card in express time machine and plant now up and running fantastic service form Sime
2 months ago
Full 12-month warranty
Available for dispatch immediately
We deliver worldwide
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
All orders are subject to product availability. See our T&Cs.
Ask our team
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
| Specification | Description |
|---|---|
| Manufacturer | SICK |
| Manufacturer Part Number | 1057651 |
| Model / Type | DT35-B15551 (Dx35 series) |
| Product Description | Mid-range time-of-flight laser distance sensor for non-contact measurement of natural targets, offering configurable switching and analogue output behaviour for industrial automation applications. |
| Measurement Principle | Time-of-flight (laser distance measurement) |
| Measurement Range (90% reflectivity) | 50 mm to 12,000 mm |
| Measurement Range (18% reflectivity) | 50 mm to 5,300 mm |
| Measurement Range (6% reflectivity) | 50 mm to 3,100 mm |
| Resolution | 0.1 mm |
| Repeatability | ≥ 0.5 mm (corresponds to 1 σ) |
| Accuracy | Typically ±10 mm |
| Response Time | 4.5 ms to 192.5 ms (selectable speed settings) |
| Switching Frequency | 166 Hz / 50 Hz / 25 Hz / 12 Hz / 3 Hz (depending on speed setting) |
| Output Time | 2 ms to 64 ms (depending on speed setting) |
| Light Source | Visible red laser |
| Laser Wavelength | 658 nm |
| Laser Class | Class 1 (IEC/EN 60825-1:2014) |
| Typical Spot Size | 15 mm × 15 mm at 2 m |
| Supply Voltage | 12 V DC to 30 V DC |
| Power Consumption | ≤ 1.7 W (without load at +20 °C) |
| IO-Link | Yes, IO-Link V1.1 |
| IO-Link Data Rate | 38.4 kbit/s |
| Digital Outputs | 1 to 2 (push-pull PNP/NPN) |
| Max Output Current (Digital) | ≤ 100 mA |
| Analogue Output | 1 (switchable) |
| Analogue Output Options | 4–20 mA (≤ 450 Ω) or 0–10 V (≥ 50 kΩ) |
| Analogue Output Resolution | 12-bit |
| Multifunction Input (MF) | 1 input (configurable: laser off / external teach / disabled) |
| Hysteresis | 0 mm to 11,950 mm (configurable via IO-Link) |
| Connection Type | Male connector, M12, 5-pin |
| Enclosure Rating | IP65 / IP67 |
| Housing Material | Plastic (ABS/PC) |
| Window Material | Plastic (PMMA) |
| Dimensions (W × H × D) | 32 mm × 58.67 mm × 42.7 mm |
| Weight | 65 g |
| Operating Temperature | −30 °C to +55 °C (with supply voltage ≤ 24 V) |
| Storage Temperature | −40 °C to +75 °C |
| Relative Humidity | ≤ 95% (non-condensing) |
| Protection Class | III |
| Initialisation Time | ≤ 500 ms |
| Warm-up Time | ≤ 20 min |
It is a laser time-of-flight distance sensor designed to measure the distance to natural targets (no reflector required). It emits visible red laser light and calculates distance from the light’s travel time.
Typical measuring ranges are 50 mm to 12,000 mm on high-reflectivity targets (90% remission), up to 5,300 mm at 18% remission, and up to 3,100 mm at 6% remission. Actual performance depends on the target surface and installation conditions.
The sensor offers a measurement resolution of 0.1 mm.
Typical accuracy is ±10 mm (depending on conditions). Repeatability is specified as at least 0.5 mm (1σ) across 6% to 90% remission targets.
Response time is selectable from 4.5 ms up to 192.5 ms depending on the configured speed setting. Switching frequency options are 166 Hz, 50 Hz, 25 Hz, 12 Hz, or 3 Hz.
It provides one analogue channel that can be configured as 4–20 mA (load up to 450 Ω) or 0–10 V (load at least 50 kΩ). Output Q2 can also be configured as a digital output, and there is also a digital output (Q1).
Yes. The digital output type is push-pull (PNP/NPN), which allows compatibility with a wide range of PLC and controller input types.
Yes, it supports IO-Link (V1.1). IO-Link can be used for process data exchange, parameter setting, diagnostics, and data storage/archiving of device parameters.
The supply voltage is 12–30 V DC. Note: when using IO-Link, the supply should be above 18 V; when using the analogue voltage output (0–10 V), the supply should be above 13 V.
It uses a 5-pin M12 male connector. Typical pin functions are: Pin 1 (brown) L+, Pin 3 (blue) M (0 V), Pin 2 (white) QA/Q2, Pin 4 (black) Q1/C, and Pin 5 (grey) multifunction input (MF).
The multifunction input can be configured for functions such as laser off, external teach-in, or deactivated. It can also be used to reset the sensor to factory settings.
The enclosure is rated IP65 and IP67. Operating ambient temperature is −30 °C to +55 °C (with supply voltage up to 24 V), and maximum relative humidity is up to 95% non-condensing.
The housing is made of plastic (ABS/PC) with a PMMA window. Dimensions are 32 mm (W) × 58.67 mm (H) × 42.7 mm (D), and typical weight is 65 g.
It supports multiple switching modes, including distance to object (DtO), window mode, and object between sensor and background (ObSB). Outputs can be taught-in and inverted depending on the application.
The sensor uses a visible red laser source and is classified as Laser Class 1 (IEC/EN 60825-1:2014).
This configuration is commonly associated with SICK article 1057651 (type DT35-B15551).
This content has been produced using multiple sources. EU Automation takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
All parts new or reconditioned are covered by EU Automation 12 month warranty
No hassle returns policy
Dedicated customer support team
We understand that credit is a necessary part of business and offer credit agreements on request, subject to status.
Payment optionsWe accept Bank transfers and the following methods of payment:
All transactions are handled securely by HSBC and HSBC Merchant Services. For more information, please visit our dedicated payments page.
Global supplier of quality automation and control components
Dispose of your old unit by exchanging it for a working part.
A comprehensive repair service for faulty equipment.
You don’t need tights and a cape to be a hero.
Get parts fast and feel like a legend, just like Jeff.