steve
Got hold of Sime for a Carrier card for…
Got hold of Sime for a Carrier card for a chiller. Machine down in a factory. Received the new card in express time machine and plant now up and running fantastic service form Sime
3 months ago
Full 12-month warranty
Available for dispatch immediately
We deliver worldwide
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
All orders are subject to product availability. See our T&Cs.
Ask our team
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
| Specification | Description |
|---|---|
| Manufacturer | Schneider |
| Part Number | XY2CH13470 |
| Product Type | Latching emergency stop rope pull switch |
| Series / Range | Telemecanique Preventa XY2 / XY2C rope pull switches |
| Device Short Name | XY2CH |
| Contact Configuration | 2 normally closed contacts |
| Contact Operation | Slow-break |
| Reset Method | Key-release pushbutton |
| Key Number | 421 |
| Housing Color | Red, RAL 3000 |
| Local Signaling | Without pilot light |
| Number of Cables | 1 |
| Maximum Trigger Cable Length | 30 m |
| Trigger Cable Anchor Point | Right-hand or left-hand side |
| Body Material | Zamak |
| Cover Material | Stainless steel |
| Terminal Type | Screw clamp terminals, 1 x 0.5 mm² to 2 x 1.5 mm² |
| Tightening Torque | 0.8 to 1.2 N.m |
| Cable Entries | 3 tapped entries for Pg 13.5 cable glands |
| Rated Operational Current | 3 A at 240 V AC-15, A300; 0.27 A at 250 V DC-13, Q300 |
| Conventional Enclosed Thermal Current | 10 A |
| Rated Insulation Voltage | 500 V conforming to EN/IEC 60947-1; 300 V conforming to UL 508 |
| Rated Impulse Withstand Voltage | 6 kV |
| Short-Circuit Protection | 10 A gG cartridge fuse |
| Positive Opening | Yes, conforming to EN/IEC 60947-5-1 |
| Mechanical Durability | 800,000 cycles |
| B10d Reliability Data | 4,000,000 operations |
| Protection Rating | IP65 conforming to IEC 60529 |
| Operating Temperature | -25 to 70 °C |
| Storage Temperature | -40 to 70 °C |
| Vibration Resistance | 10 gn, 10 to 150 Hz, conforming to EN/IEC 60068-2-6 |
| Shock Resistance | 50 gn for 11 ms, conforming to EN/IEC 60068-2-27 |
| Standards | EN/IEC 60947-5-1, EN/IEC 60947-5-5, EN/ISO 13850, EN/IEC 60204-1 |
| Certifications | UL category NISD emergency stop devices, CCC |
| Net Weight | 0.91 kg |
| Approximate Dimensions | 201 x 68 x 95 mm |
| Commodity Code | 85365080 |
This is a latching emergency stop rope pull switch designed for machinery applications where an emergency stop command must be activated by pulling a tensioned cable. It is part of the Telemecanique Emergency Stop Rope Pull Switches XY2C range and uses a key-release pushbutton reset.
The switch has 2 normally closed contacts. The contact operation is slow-break, and the device includes positive opening in accordance with EN/IEC 60947-5-1.
The maximum trigger cable length is 30 m, or approximately 98.43 ft. The device is designed for one cable and can be anchored from either the right-hand or left-hand side.
After the rope pull mechanism is activated, the switch is reset using a key-release pushbutton. The specified key number for this model is 421.
The rated operational current is 3 A at 240 V AC-15, A300, and 0.27 A at 250 V DC-13, Q300. It also has a conventional enclosed thermal current of 10 A, a rated insulation voltage of 500 V under EN/IEC 60947-1, and a rated impulse withstand voltage of 6 kV.
The switch uses screw clamp terminals suitable for 1 x 0.5 mm² to 2 x 1.5 mm² conductors. The recommended tightening torque is 0.8 to 1.2 N.m.
The enclosure includes 3 tapped entries for Pg 13.5 cable glands, giving installers flexibility when routing wiring into the switch body.
The body is made from Zamak and the cover is stainless steel. The housing color is red, RAL 3000, which is typical for emergency stop devices.
The device has an IP65 degree of protection in accordance with IEC 60529, helping protect it against dust ingress and low-pressure water jets when properly installed.
The operating temperature range is -25 to 70 °C, equivalent to -13 to 158 °F. The storage temperature range is -40 to 70 °C, equivalent to -40 to 158 °F.
The switch is associated with standards including EN/IEC 60947-5-1, EN/IEC 60947-5-5, EN/ISO 13850, EN/IEC 60204-1, Machinery Directive 2006/42/EC, and Work Equipment Directive 2009/104/EC. Product certifications include UL category NISD emergency stop devices and CCC.
With an appropriate monitoring system and correct wiring, XY2CH13470 can reach PL = e and category 4 according to EN/ISO 13849-1, and SIL 3 according to EN/IEC 61508.
The listed dimensions are 201 x 68 x 95 mm. The net weight is approximately 0.91 kg, or 2.01 lb.
This content has been produced using multiple sources. EU Automation takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
All parts new or reconditioned are covered by EU Automation 12 month warranty
No hassle returns policy
Dedicated customer support team
We understand that credit is a necessary part of business and offer credit agreements on request, subject to status.
Payment optionsWe accept Bank transfers and the following methods of payment:
All transactions are handled securely by HSBC and HSBC Merchant Services. For more information, please visit our dedicated payments page.
Global supplier of quality automation and control components
Dispose of your old unit by exchanging it for a working part.
A comprehensive repair service for faulty equipment.
You don’t need tights and a cape to be a hero.
Get parts fast and feel like a legend, just like Jeff.