steve
Got hold of Sime for a Carrier card for…
Got hold of Sime for a Carrier card for a chiller. Machine down in a factory. Received the new card in express time machine and plant now up and running fantastic service form Sime
3 months ago
Full 12-month warranty
Available for dispatch immediately
We deliver worldwide
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
All orders are subject to product availability. See our T&Cs.
Ask our team
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
| Specification | Description |
|---|---|
| Part Number | XPSTSW5142P |
| Manufacturer | Schneider |
| Category | Safety Automation |
| Family | XPS |
| Product Type | Preventa safety time delay module |
| Application | Designed for applications requiring safety switchover contact |
| Function | Monitors safety time delays |
| Safety Level | Achieves PL d/category 3 according to EN/ISO 13849-1 and SILCL 2 according to EN/IEC 62061 |
| Rated Supply Voltage | 24 V AC/DC |
| Output Type | Relay, 1 NO + 2 NC, volt-free |
| Additional Circuits | 2 solid state outputs |
| Supply Frequency | 50/60 Hz |
| Power Consumption | 2.3 VA DC, 4.3 VA AC |
| Input Protection Type | Internal, electronic |
| Time Delay | Configurable from 1 to 31 seconds |
| Impulse Duration | Adjustable from 0.1 to 3.1 seconds |
| Breaking Capacity | 180 VA holding, 1800 VA inrush for AC-15 C300 relay output; 10 mA at 48 V, 20 mA at 24 V for solid state output circuit; 1.5 A at 24 V DC-13 for relay output |
| Conventional Thermal Current | 6 A for relay output |
| Associated Fuse Rating | 4 A gG and 6 A fast blow for relay output according to EN/IEC 60947-5-1, DIN VDE 0660 part 200 |
| Minimum Output Current | 10 mA for relay output |
| Minimum Output Voltage | 17 V for relay output |
| Rated Insulation Voltage | 300 V according to IEC 60947-5-1 and DIN VDE 0110 part 1 |
| Rated Impulse Withstand Voltage | 4 kV according to IEC 60947-5-1 and DIN VDE 0110 part 1 |
| Local Signalling | 4 LEDs |
| Connections - Terminals | Captive screw clamp terminals, removable terminal block for flexible and solid cables with various configurations |
| Mounting Support | 35 mm symmetrical DIN rail |
| Dimensions | Depth: 114 mm, Height: 99 mm, Width: 45 mm |
| Net Weight | 0.25 kg |
| Standards | Complies with EN/IEC 60204-1, EN/IEC 60947-5-1 |
| Product Certifications | UL, TÜV, CSA |
| IP Degree of Protection | IP20 for terminals, IP40 for enclosure according to EN/IEC 60529 |
| Ambient Air Temperature | Operational: -10 to 55 °C, Storage: -25 to 85 °C |
| Sustainable Offer Status | Green Premium product |
| Environmental Compliance | PVC free, Mercury free, Pro-active compliance with EU RoHS Directive, China RoHS Declaration, REACh Declaration |
| California Proposition 65 | WARNING: This product can expose you to chemicals including lead and lead compounds, known to cause cancer and birth defects or other reproductive harm. |
This safety module is designed for applications with safety switchover contact, providing monitoring of safety time delays.
The module features a relay output with 1 normally open (NO) and 2 normally closed (NC) contacts, along with 2 solid state outputs.
The module operates at a rated supply voltage of 24 V AC/DC.
The module measures 114 mm in depth, 99 mm in height, and 45 mm in width.
The module has an IP20 rating for terminals and an IP40 rating for the enclosure, according to EN/IEC 60529 standards.
The time delay is configurable from 1 to 31 seconds.
The module is designed to be mounted on a 35 mm symmetrical DIN rail.
The module complies with EN/IEC 60204-1 and EN/IEC 60947-5-1 standards.
The maximum power consumption is 2.3 VA for DC and 4.3 VA for AC.
The relay output has a breaking capacity of 180 VA holding and 1800 VA inrush for AC-15 C300 applications.
This content has been produced using multiple sources. EU Automation takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
All parts new or reconditioned are covered by EU Automation 12 month warranty
No hassle returns policy
Dedicated customer support team
We understand that credit is a necessary part of business and offer credit agreements on request, subject to status.
Payment optionsWe accept Bank transfers and the following methods of payment:
All transactions are handled securely by HSBC and HSBC Merchant Services. For more information, please visit our dedicated payments page.
Global supplier of quality automation and control components
Dispose of your old unit by exchanging it for a working part.
A comprehensive repair service for faulty equipment.
You don’t need tights and a cape to be a hero.
Get parts fast and feel like a legend, just like Jeff.