steve
Got hold of Sime for a Carrier card for…
Got hold of Sime for a Carrier card for a chiller. Machine down in a factory. Received the new card in express time machine and plant now up and running fantastic service form Sime
3 months ago
Full 12-month warranty
Available for dispatch immediately
We deliver worldwide
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
All orders are subject to product availability. See our T&Cs.
Ask our team
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
| Specification | Description |
|---|---|
| Part Number | XCSPA591 |
| Manufacturer | Schneider |
| Product Type | Safety Switch |
| Range of Product | Preventa Safety detection |
| Design | Compact |
| Material | Plastic |
| Head Type | Key operated turret head |
| Contacts Type and Composition | 1 NC + 1 NO |
| Contact Operation | Slow-break, break before make |
| Cable Entry | 1 entry tapped Pg 11 |
| Cable Outer Diameter | 0.28...0.39 in (7...10 mm) |
| Electrical Connection | Terminal, 1 x 0.5...2 x 1.5 mm² with or without cable end |
| Number of Poles | 2 |
| Locking Options Description | Without locking of actuator |
| Insulation | Double insulated |
| Positive Opening | With NC contact |
| Mechanical Durability | ≥ 1000000 cycles |
| Positive Opening Minimum Force | 15 N |
| Minimum Actuation Speed | 0.03 ft/s (0.01 m/s) |
| Maximum Actuation Speed | 1.64 ft/s (0.5 m/s) |
| Rated Operational Current [Ie] | 6 A at 120 V AC-15, A300; 3 A at 240 V AC-15, A300; 0.55 A at 125 V DC-13, Q300; 0.27 A at 250 V DC-13, Q300 |
| Conventional Enclosed Thermal Current [Ithe] | 10 A |
| Rated Insulation Voltage [Ui] | 500 V conforming to EN/IEC 60947-1; 300 V conforming to UL 508; 300 V conforming to CSA C22.2 No 14 |
| Rated Impulse Withstand Voltage [Uimp] | 6 kV conforming to EN/IEC 60947-5-1 |
| Short-Circuit Protection | 10 A cartridge fuse type gG (gl) |
| Actuator Forcible Withdrawal | 10 N |
| Operating Rate | 10 cycles/min for maximum durability |
| Safety Level | Can reach category 4, PL = e, SIL 3 with appropriate monitoring system and correct wiring |
| Safety Reliability Data | B10d = 5000000 (value given for a lifetime of 20 years limited by mechanical or contact wear) |
| Body Material | PA (polyamide) |
| Head Material | PA (polyamide) |
| Dimensions | Depth: 1.18 in (30 mm), Height: 3.7 in (94 mm), Width: 1.18 in (30 mm) |
| Product Weight | 0.24 lb (0.11 kg) |
| Standards | EN/IEC 60947-5-1, CSA C22.2 No 14, EN/ISO 12100, EN/IEC 60204-1, EN 1088/ISO 14119, UL 508 |
| Product Certifications | UL, CSA |
| Protective Treatment | TC |
| Ambient Air Temperature for Operation | -13...158 °F (-25...70 °C) |
| Ambient Air Temperature for Storage | -40...158 °F (-40...70 °C) |
| Vibration Resistance | 5 gn (f = 10...500 Hz) conforming to IEC 60068-2-6 |
| Shock Resistance | 10 gn for 11 ms conforming to IEC 60068-2-27 |
| Electrical Shock Protection Class | Class II conforming to EN/IEC 61140 |
| IP Degree of Protection | IP67 conforming to EN/IEC 60529 and EN/IEC 60947-5-1 |
| Sustainable Offer Status | Green Premium product |
| Toxic Heavy Metal Free | Yes |
| Mercury Free | Yes |
| RoHS Exemption Information | Yes |
| Environmental Disclosure | Product Environmental Profile, Circularity Profile, End of Life Information |
| California Proposition 65 | WARNING: This product can expose you to chemicals including Diisononyl phthalate (DINP) and Di-isodecyl phthalate (DIDP), known to the State of California to cause cancer and birth defects or other reproductive harm. For more information, visit www.P65Warnings.ca.gov |
This is a key-operated turret head safety switch from the Telemecanique Safety switches XCS range, designed for reliable safety detection.
The safety switch features a compact design, double insulation, and a key-operated turret head. It has 1 NC + 1 NO contact configuration and supports slow-break, break-before-make contact operation.
The safety switch has a terminal electrical connection with a clamping capacity of 1 x 0.5 to 2 x 1.5 mm², with or without cable end.
The mechanical durability of this safety switch is rated at 1,000,000 cycles, ensuring long-lasting performance.
This safety switch complies with standards such as EN/IEC 60947-5-1, CSA C22.2 No 14, EN/ISO 12100, EN/IEC 60204-1, EN 1088/ISO 14119, and UL 508. It is also certified by UL and CSA.
The safety switch has an IP67 degree of protection, making it suitable for use in environments where it may be exposed to dust and water.
The safety switch measures 30 x 94 x 30 mm and weighs 0.11 kg.
The rated operational current is 6 A at 120 V for AC-15, A300, and 3 A at 240 V for AC-15, A300. For DC-13, Q300, it is 0.55 A at 125 V and 0.27 A at 250 V.
The positive opening minimum force for this safety switch is 15 N.
This safety switch can reach safety levels such as category 4, PL = e, and SIL 3 when used with the appropriate monitoring system and correctly wired.
This content has been produced using multiple sources. EU Automation takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
All parts new or reconditioned are covered by EU Automation 12 month warranty
No hassle returns policy
Dedicated customer support team
We understand that credit is a necessary part of business and offer credit agreements on request, subject to status.
Payment optionsWe accept Bank transfers and the following methods of payment:
All transactions are handled securely by HSBC and HSBC Merchant Services. For more information, please visit our dedicated payments page.
Global supplier of quality automation and control components
Dispose of your old unit by exchanging it for a working part.
A comprehensive repair service for faulty equipment.
You don’t need tights and a cape to be a hero.
Get parts fast and feel like a legend, just like Jeff.