steve
Got hold of Sime for a Carrier card for…
Got hold of Sime for a Carrier card for a chiller. Machine down in a factory. Received the new card in express time machine and plant now up and running fantastic service form Sime
3 months ago
Full 12-month warranty
Available for dispatch immediately
We deliver worldwide
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
All orders are subject to product availability. See our T&Cs.
Ask our team
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
| Specification | Description |
|---|---|
| Manufacturer | Schneider Electric |
| Part Number | XB4BVB5EX |
| Product Range | Harmony XB4 |
| Product Type | Complete pilot light (integral LED) |
| Description | 22 mm Harmony XB4 complete pilot light with integral LED for clear panel indication, featuring a robust metal bezel and ATEX dust certification for use in Zone 21/22 applications. |
| Mounting Diameter | 22 mm |
| Recommended Panel Cut-out | Ø 22.5 mm (Ø 22.3 mm 0/+0.4 permissible) |
| Support Thickness (Panel) | 1 to 6 mm |
| Head Shape | Round |
| Lens Type | Plain lens |
| Lens/Indicator Colour | Orange (amber) |
| Signalling Type | Steady |
| Light Source | Integral LED |
| Rated Supply Voltage (Us) | 24 V AC/DC, 50/60 Hz |
| Supply Voltage Limits | 19.2…30 V DC; 21.6…26.4 V AC |
| Current Consumption | 18 mA |
| LED Service Life | 100,000 h (at rated voltage and 25 °C) |
| Connections / Terminals | Screw clamp terminals |
| Terminal Capacity (with cable end) | ≤ 2 × 1.5 mm² (to EN/IEC 60947-1) |
| Terminal Capacity (without cable end) | 1 × 0.22 mm² to 2 × 2.5 mm² (to EN/IEC 60947-1) |
| Rated Insulation Voltage (Ui) | 250 V (pollution degree 3) |
| Rated Impulse Withstand Voltage (Uimp) | 4 kV |
| Surge Withstand | 1 kV (IEC 61000-4-5) |
| ATEX / Ex Marking | Ex tb IIIC |
| Dust Zone Classification | Zone 21 – 22 |
| IP Rating | IP65 |
| NEMA Rating | NEMA 13; NEMA 4X |
| Impact Resistance | IK05 |
| Bezel Material | Chromium plated metal |
| Fixing Collar Material | Zamak |
| Protective Treatment | TH |
| Operating Ambient Temperature | -20…60 °C |
| Storage Ambient Temperature | -40…70 °C |
| Applicable Standards (selection) | IEC 60079-0; EN 60079-31; IEC 61000-6-2; IEC 60079-31 |
It is a complete 22 mm panel-mount pilot light used to provide a clear visual status indication on control panels and operator stations. It uses an integral LED and provides a steady (non-flashing) indication.
It is designed for a 22 mm mounting system with a recommended finished panel cut-out of 22.5 mm (acceptable tolerance is 22.3 mm with +0.4/0).
Allow for an embedding depth of approximately 43 mm behind the panel for the body of the pilot light and wiring clearance.
It is intended for support (panel) thicknesses from 1 mm to 6 mm.
It is rated for 24 V AC/DC (50/60 Hz). Typical operating limits are 19.2 to 30 V DC and 21.6 to 26.4 V AC.
Current consumption is approximately 18 mA at the rated supply voltage.
The light source is an integral LED, meaning there is no separate lamp to fit. The rated service life is 100,000 hours at rated voltage and 25 °C.
This model provides an amber/orange indication (often described as “yellow” in pilot light colour naming). It uses a plain lens and an orange/amber LED indication.
It is rated IP65. It is also referenced with NEMA 13 and NEMA 4X performance ratings.
Yes. It is intended for ATEX dust environments and is specified for dust Zone 21–22 with marking Ex tb IIIC. If you need the exact marking on a listing, you can reference Schneider XB4BVB5EX.
It uses screw clamp terminals. Typical clamping capacities include up to 2 x 1.5 mm² when using cable ends, and 1 x 0.22 mm² to 2 x 2.5 mm² without cable ends (per IEC 60947-1 practices).
It has IK05 impact resistance, vibration resistance of 5 gn (12…500 Hz), and shock resistance of 30 gn (18 ms) and 50 gn (11 ms). It also has surge withstand of 1 kV (IEC 61000-4-5) and fast transient immunity of 2 kV (IEC 61000-4-4).
Typical ambient ranges are -20 °C to +60 °C during operation and -40 °C to +70 °C during storage.
Key insulation coordination values include a rated insulation voltage (Ui) of 250 V (pollution degree 3) and a rated impulse withstand voltage (Uimp) of 4 kV, in line with IEC 60947-1.
This content has been produced using multiple sources. EU Automation takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
All parts new or reconditioned are covered by EU Automation 12 month warranty
No hassle returns policy
Dedicated customer support team
We understand that credit is a necessary part of business and offer credit agreements on request, subject to status.
Payment optionsWe accept Bank transfers and the following methods of payment:
All transactions are handled securely by HSBC and HSBC Merchant Services. For more information, please visit our dedicated payments page.
Global supplier of quality automation and control components
Dispose of your old unit by exchanging it for a working part.
A comprehensive repair service for faulty equipment.
You don’t need tights and a cape to be a hero.
Get parts fast and feel like a legend, just like Jeff.