steve
Got hold of Sime for a Carrier card for…
Got hold of Sime for a Carrier card for a chiller. Machine down in a factory. Received the new card in express time machine and plant now up and running fantastic service form Sime
3 weeks ago
Full 12-month warranty
Available for dispatch immediately
We deliver worldwide
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
All orders are subject to product availability. See our T&Cs.
Ask our team
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
| Specification | Description |
|---|---|
| Part Number | XACA12H7 |
| Manufacturer | Schneider |
| Product Type | Pendant Control Station |
| Range of Product | Harmony XAC |
| Enclosure Material | Polypropylene |
| Electrical Circuit Type | Control Circuit |
| Enclosure Type | Empty Enclosure |
| Number of Cut-outs | 12 Cut-outs |
| Control Station Colour | Yellow |
| Cable Entry | Rubber Sleeve with Stepped Entry (8...26 mm) |
| Guard Rail | Without |
| Vertical Operator Cut-out Centre | 30 mm |
| Standards | CSA C22.2 No 14, EN/IEC 60204-32, EN/IEC 60947-5-1, UL 508 |
| Product Certifications | CCC, CSA, GOST, UL |
| Protective Treatment | TH |
| Ambient Air Temperature for Operation | -25...70 °C |
| Ambient Air Temperature for Storage | -40...70 °C |
| Vibration Resistance | 15 gn (10...500 Hz) conforming to IEC 60068-2-6 |
| Shock Resistance | 100 gn conforming to IEC 60068-2-27 |
| Overvoltage Category | Class II conforming to IEC 61140 |
| IP Degree of Protection | IP65 conforming to IEC 60529 |
| IK Degree of Protection | IK08 conforming to EN 50102 |
| Mechanical Durability | 1,000,000 cycles |
| Product Weight | 1 kg |
| Sustainable Offer Status | Green Premium Product |
| Toxic Heavy Metal Free | Yes |
| Mercury Free | Yes |
| REACh Free of SVHC | Yes |
| EU RoHS Directive | Pro-active compliance (Product out of EU RoHS legal scope) |
| China RoHS Regulation | China RoHS Declaration |
| Environmental Disclosure | Product Environmental Profile |
| California Proposition 65 | WARNING: This product can expose you to chemicals including Nickel compounds and Di-isodecyl phthalate (DIDP) which are known to the State of California to cause cancer and reproductive harm. For more information, visit www.p65warnings.ca.gov |
The Schneider XACA12H7 is a robust and versatile pendant control station designed for industrial applications. Part of the Harmony XAC range, this control station features a durable polypropylene enclosure and is equipped with 12 cut-outs for customisation. It is suitable for control circuits and offers a high degree of protection with IP65 and IK08 ratings. The XACA12H7 is compliant with multiple international standards and certifications, ensuring reliable performance in various environments. Its sustainable design is free from toxic heavy metals and mercury, aligning with global environmental regulations.
The primary function of this pendant control station is to provide a user interface for controlling machinery and equipment in industrial settings.
This control station features 12 cut-outs, allowing for multiple control elements to be installed.
The enclosure of this control station is made of durable polypropylene.
Yes, this control station is double insulated for added safety.
The control station has an IP65 degree of protection, making it dust-tight and protected against water jets.
The control station with 12 cut-outs has dimensions of 680 mm in length, 490 mm in width, and 92 mm in height.
The mechanical durability of this control station is rated at 1,000,000 cycles.
The operating temperature range for this control station is from -25°C to 70°C.
Yes, this control station complies with standards such as CSA C22.2 No 14, EN/IEC 60947-5-1, UL 508, and EN/IEC 60204-32.
This control station features a rubber sleeve with a stepped entry, suitable for cable diameters ranging from 8 mm to 26 mm.
This content has been produced using multiple sources. EU Automation takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
All parts new or reconditioned are covered by EU Automation 12 month warranty
No hassle returns policy
Dedicated customer support team
We understand that credit is a necessary part of business and offer credit agreements on request, subject to status.
Payment optionsWe accept Bank transfers and the following methods of payment:
All transactions are handled securely by HSBC and HSBC Merchant Services. For more information, please visit our dedicated payments page.
Global supplier of quality automation and control components
Dispose of your old unit by exchanging it for a working part.
A comprehensive repair service for faulty equipment.
You don’t need tights and a cape to be a hero.
Get parts fast and feel like a legend, just like Jeff.