steve
Got hold of Sime for a Carrier card for…
Got hold of Sime for a Carrier card for a chiller. Machine down in a factory. Received the new card in express time machine and plant now up and running fantastic service form Sime
3 months ago
Full 12-month warranty
Available for dispatch immediately
We deliver worldwide
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
All orders are subject to product availability. See our T&Cs.
Ask our team
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
| Specification | Description |
|---|---|
| Manufacturer | Schneider Electric |
| Part Number | VCCD2 |
| Range | TeSys |
| Product Family | TeSys Vario |
| Product Type | Emergency-stop switch disconnector |
| Performance Level | High performance |
| Device Composition | Rotary handle, switch body and shaft extension |
| Number of Poles | 3 |
| Contact Configuration | 3 normally open contacts |
| Network Type | AC and DC |
| Control Type | Extended rotary handle |
| Handle Colour | Red |
| Front Plate Colour | Yellow |
| Position Marking | 0–1 |
| Isolation Capability | Suitable for isolation |
| Mounting Arrangement | Handle mounts through the enclosure door; switch mounts on a symmetrical rail or plate |
| Handle Fixing Diameter | 22.5 mm |
| Padlocking Provision | Accommodates 1–3 padlocks with 4–8 mm shackles |
| Rated Operational Voltage | 690 V AC, 50/60 Hz |
| Rated Impulse Withstand Voltage | 8 kV |
| Conventional Free-Air Thermal Current | 40 A |
| Conventional Enclosed Thermal Current | 32 A |
| Rated Operational Current | 29 A at 400 V AC-23 |
| Motor Rating at 230–240 V | 5.5 kW AC-3; 7.5 kW AC-23A |
| Motor Rating at 400–415 V | 11 kW AC-3; 15 kW AC-23A |
| Motor Rating at 500 V | 15 kW AC-3; 18.5 kW AC-23A |
| Motor Rating at 690 V | 11 kW AC-3; 15 kW AC-23A |
| Making Capacity | 400 A at 400 V for AC-21A, AC-22A and AC-23A |
| Breaking Capacity | 320 A at 400 V for AC-21A, AC-22A and AC-23A |
| Short-Circuit Making Capacity | 1 kA peak at 400 V |
| Short-Time Withstand Current | 480 A at 400 V for 1 second |
| Conditional Short-Circuit Current | 10 kA at 400 V with an associated 50 A aM or gG fuse |
| Intermittent Duty Class | Class 30 |
| Mechanical Durability | 100,000 operating cycles |
| Electrical Durability | 100,000 cycles for AC-21; 30,000 cycles for DC-1 to DC-5 |
| Terminal Type | Screw-clamp power terminals |
| Terminal Capacity | 10 mm² solid conductor or 6 mm² flexible conductor with cable end |
| Terminal Tightening Torque | 2.1 N·m |
| Front Plate Dimensions | 60 × 60 mm |
| Product Dimensions | 74 mm high × 60 mm wide |
| Product Weight | 0.392 kg |
| Degree of Protection | IP65 at the operator interface; IP20 at protected internal components |
| Operating Temperature | -20 to +50 °C |
| Vibration Resistance | 1 gn from 10 to 150 Hz, in accordance with IEC 60068-2-6 |
| Shock Resistance | 30 gn for 11 ms, in accordance with IEC 60068-2-27 |
| Fire Resistance | 960 °C, in accordance with IEC 60695-2-1 |
| Applicable Standard | IEC 60947-3 |
| Certifications | CSA, UL, GL, CCC and UKCA |
| Environmental Compliance | EU RoHS compliant, mercury-free, PVC-free and halogen-free |
| Country of Origin | Czech Republic |
The VCCD2 is a TeSys Vario emergency-stop switch disconnector designed to isolate an electrical circuit using a red rotary handle mounted on a yellow front plate.
It has three poles with three normally open main contacts, making it suitable for switching and isolating three-phase circuits.
The unit is rated for operational voltages up to 690 V AC at 50 or 60 Hz.
It has a conventional free-air thermal current rating of 40 A and a conventional enclosed thermal current rating of 32 A. Its rated operational current is 29 A at 400 V in the AC-23 utilisation category.
At 400 to 415 V, the rated operational power is 11 kW for AC-3 applications and 15 kW for AC-23A applications.
The extended rotary handle is intended for mounting through an enclosure door using a 22.5 mm fixing hole. The switch body can be fitted to a symmetrical rail or mounting plate.
Yes. The rotary handle accepts between one and three padlocks with shackle diameters from 4 to 8 mm. The handle is marked with 0 and 1 positions.
The VCCD2 assembly consists of the switch body, an extended shaft and a red rotary handle with a yellow 60 x 60 mm front plate.
The product data specifies IP65 protection for the externally mounted handle and IP20 protection for the switch body, in accordance with IEC 60529.
The specified ambient operating temperature range is from -20°C to 50°C.
The screw-clamp power terminals accept solid conductors up to 10 mm² and flexible conductors with cable ends up to 6 mm².
The specified tightening torque for the power-circuit screw-clamp terminals is 2.1 N·m.
The front plate measures 60 x 60 mm, the overall stated height is 74 mm, the width is 60 mm and the product weight is approximately 0.392 kg.
The device is rated for 100,000 mechanical operating cycles. Electrical endurance is 100,000 cycles for AC-21 duty and 30,000 cycles for DC-1 to DC-5 duty.
The device conforms to IEC 60947-3, the standard covering switches, disconnectors, switch-disconnectors and fuse-combination units.
The specified conditional short-circuit current is 10 kA at 400 V when used with an associated 50 A aM or gG fuse. The short-time withstand current is 480 A for one second at 400 V.
Yes. It is specifically rated as suitable for isolation and functions as a main switch disconnector with emergency-stop operation.
Yes. The product specification identifies compatibility with AC and DC networks, although the applicable current rating depends on the voltage and utilisation category.
This content has been produced using multiple sources. EU Automation takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
All parts new or reconditioned are covered by EU Automation 12 month warranty
No hassle returns policy
Dedicated customer support team
We understand that credit is a necessary part of business and offer credit agreements on request, subject to status.
Payment optionsWe accept Bank transfers and the following methods of payment:
All transactions are handled securely by HSBC and HSBC Merchant Services. For more information, please visit our dedicated payments page.
Global supplier of quality automation and control components
Dispose of your old unit by exchanging it for a working part.
A comprehensive repair service for faulty equipment.
You don’t need tights and a cape to be a hero.
Get parts fast and feel like a legend, just like Jeff.