steve
Got hold of Sime for a Carrier card for…
Got hold of Sime for a Carrier card for a chiller. Machine down in a factory. Received the new card in express time machine and plant now up and running fantastic service form Sime
3 months ago
Full 12-month warranty
Available for dispatch immediately
We deliver worldwide
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
All orders are subject to product availability. See our T&Cs.
Ask our team
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
| Specification | Description |
|---|---|
| Product Name | Schneider TM5SAI4PH |
| Product Type | Analog Input Module |
| Analogue Input Number | 4 |
| Analogue Input Type | Pt 100/Pt 1000 temperature probe, suitable for a range of -200 to 850 °C |
| Analogue Input Resolution | 16 bits |
| Measurement Resolution | 0.1 °C |
| Measurement Error | Less than 0.037% of full scale for Pt 100/Pt 1000 at 25 °C |
| Temperature Coefficient | 0.004 %FS/°C |
| Non-linearity | 0.001 %FS |
| Type of Cable | Shielded cable |
| Isolation | No insulation between channels; 500 Vrms AC insulation between channel and bus |
| Rated Supply Voltage | 24 V DC with a tolerance of -15% to +20% |
| Current Consumption | 2 mA at 5 V DC bus, 46 mA at 24 V DC input/output |
| Maximum Power Dissipation | 1.11 W |
| Local Signalling | 1 LED green for power supply, 1 LED red for power supply, 4 LEDs green for input status |
| Operating Temperature | 0 to 55 °C without derating (horizontal installation), 0 to 60 °C with derating factor (horizontal installation), 0 to 50 °C (vertical installation) |
| Storage Temperature | -25 to 70 °C |
| Relative Humidity | 5% to 95% without condensation |
| IP Degree of Protection | IP20 conforming to IEC 61131-2 |
| Pollution Degree | 2 conforming to IEC 60664 |
| Operating Altitude | 0 to 2000 m |
| Storage Altitude | 0 to 3000 m |
| Vibration Resistance | 1 gn at 8.4 to 150 Hz on DIN rail, 3.5 mm at 5 to 8.4 Hz on DIN rail |
| Shock Resistance | 15 gn for 11 ms |
| Resistance to Electrostatic Discharge | 4 kV on contact conforming to EN/IEC 61000-4-2, 8 kV in air conforming to EN/IEC 61000-4-2 |
| Resistance to Electromagnetic Fields | 1 V/m at 2 to 2.7 GHz conforming to EN/IEC 61000-4-3, 10 V/m at 80 to 2000 MHz conforming to EN/IEC 61000-4-3 |
| Resistance to Fast Transients | 1 kV (I/O) conforming to EN/IEC 61000-4-4, 1 kV (shielded cable) conforming to EN/IEC 61000-4-4, 2 kV (power lines) conforming to EN/IEC 61000-4-4 |
| Surge Withstand | 0.5 kV differential mode conforming to EN/IEC 61000-4-5, 1 kV common mode conforming to EN/IEC 61000-4-5 |
| Electromagnetic Compatibility | EN/IEC 61000-4-6 |
| Disturbance Radiated/Conducted | CISPR 11 |
| Colour | White |
| Net Weight | 0.025 kg |
| Sustainable Offer Status | Green Premium product |
| Toxic Heavy Metal Free | Yes |
| Mercury Free | Yes |
| PVC Free | Yes |
The module supports analog inputs specifically designed for Pt 100/Pt 1000 temperature probes.
This module can measure temperatures ranging from -200 to 850 degrees Celsius.
The analog input module has a resolution of 16 bits.
Yes, the module features local signalling with one green LED for power supply, one red LED for power supply, and four green LEDs for input status.
The module operates with a rated supply voltage of 24 V DC, with a tolerance of -15% to +20%.
The maximum power dissipation of the module is 1.11 watts.
The module has a common mode rejection ratio of greater than 95 dB.
It is recommended to use a shielded cable with this module to ensure optimal performance.
No, there is no isolation between channels, but there is 500 Vrms AC isolation between the channel and the bus.
The measurement error is less than 0.037% of the full scale for temperatures between -200 and 850 degrees Celsius at 25 degrees Celsius.
This content has been produced using multiple sources. EU Automation takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
All parts new or reconditioned are covered by EU Automation 12 month warranty
No hassle returns policy
Dedicated customer support team
We understand that credit is a necessary part of business and offer credit agreements on request, subject to status.
Payment optionsWe accept Bank transfers and the following methods of payment:
All transactions are handled securely by HSBC and HSBC Merchant Services. For more information, please visit our dedicated payments page.
Global supplier of quality automation and control components
Dispose of your old unit by exchanging it for a working part.
A comprehensive repair service for faulty equipment.
You don’t need tights and a cape to be a hero.
Get parts fast and feel like a legend, just like Jeff.