steve
Got hold of Sime for a Carrier card for…
Got hold of Sime for a Carrier card for a chiller. Machine down in a factory. Received the new card in express time machine and plant now up and running fantastic service form Sime
3 months ago
Full 12-month warranty
Available for dispatch immediately
We deliver worldwide
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
All orders are subject to product availability. See our T&Cs.
Ask our team
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
| Specification | Description |
|---|---|
| Part Number | TM3DQ32TK |
| Manufacturer | Schneider |
| Output Type | Discrete Output Module |
| Number of Outputs | 32 |
| Output Logic | Positive logic (source) |
| Output Voltage | 24 V DC for transistor output |
| Output Current | 100 mA for transistor output |
| Current Consumption | 5 mA at 5 V DC (off state), 0 mA at 24 V DC (off state), 25 mA at 5 V DC (on state), 40 mA at 24 V DC (on state) |
| Response Time | 450 µs for turn-on and turn-off |
| Leakage Current | 0.1 mA for transistor output |
| Voltage Drop | <0.4 V |
| Tungsten Load | <1.2 W for transistor output |
| Local Signalling | Green LED for output status |
| Electrical Connection | HE-10 connector for outputs |
| Insulation | 500 V AC between output and internal logic, non-insulated between outputs |
| Mounting Support | Top hat type TH35-15 rail conforming to IEC 60715, top hat type TH35-7.5 rail conforming to IEC 60715, plate or panel with fixing kit |
| Dimensions (H x D x W) | 90 mm x 81.3 mm x 33.5 mm |
| Product Weight | 0.112 kg |
| Standards | EN/IEC 61131-2, EN/IEC 61010-2-201 |
| Product Certifications | C-tick, cULus |
| Environmental Resistance | Electrostatic discharge, electromagnetic fields, magnetic fields, fast transients, surge withstand |
| Operating Temperature | -10...55 °C for horizontal installation, -10...35 °C for vertical installation |
| Storage Temperature | -25...70 °C |
| Relative Humidity | 10...95 % without condensation in operation and storage |
| IP Degree of Protection | IP20 with protective cover in place |
| Pollution Degree | 2 |
| Operating Altitude | 0...2000 m |
| Storage Altitude | 0...3000 m |
| Vibration Resistance | 3.5 mm at 5...8.4 Hz, 3 gn at 8.4...150 Hz on DIN rail and panel |
| Shock Resistance | 15 gn for 11 ms |
| Sustainable Offer Status | Green Premium product |
| RoHS Compliance | Pro-active compliance (Product out of EU RoHS legal scope) |
| Toxic Heavy Metal Free | Yes |
| Mercury Free | Yes |
| RoHS Exemption Information | Yes |
| Environmental Disclosure | Product Environmental Profile available |
| End of Life Information | End Of Life manual available |
| PVC Free | Yes |
The discrete output module features 32 transistor outputs with PNP configuration, suitable for various industrial applications.
This module is compatible with Modicon M221, M241, M251, and M262 controllers, ensuring seamless integration with these specific Schneider Electric platforms.
The transistor outputs are rated for 24 V DC, providing a reliable and consistent performance for connected devices.
The module consumes 5 mA at 5 V DC via the bus connector when in the off state, and 40 mA at 24 V DC via the bus connector when in the on state.
Each output channel has a green LED indicator to show its status, offering clear and immediate visual feedback for operational monitoring.
The module is designed to mount on a top hat type TH35-15 rail conforming to IEC 60715, as well as a TH35-7.5 rail or a plate or panel with a fixing kit.
The maximum cable distance for the transistor outputs is 5 meters when using an unshielded cable, which helps to maintain signal integrity over distance.
Yes, the module has been designed with resistance to various forms of electromagnetic interference, including electrostatic discharge, electromagnetic fields, and fast transients.
The module can operate in ambient air temperatures ranging from -10 to 55 degrees Celsius for horizontal installation and -10 to 35 degrees Celsius for vertical installation, with a relative humidity range of 10 to 95% without condensation.
Yes, it is a Green Premium product, which means it complies with the latest environmental standards and regulations, including RoHS and REACh.
This content has been produced using multiple sources. EU Automation takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
All parts new or reconditioned are covered by EU Automation 12 month warranty
No hassle returns policy
Dedicated customer support team
We understand that credit is a necessary part of business and offer credit agreements on request, subject to status.
Payment optionsWe accept Bank transfers and the following methods of payment:
All transactions are handled securely by HSBC and HSBC Merchant Services. For more information, please visit our dedicated payments page.
Global supplier of quality automation and control components
Dispose of your old unit by exchanging it for a working part.
A comprehensive repair service for faulty equipment.
You don’t need tights and a cape to be a hero.
Get parts fast and feel like a legend, just like Jeff.