Full 12-month warranty
Available for dispatch immediately
We deliver worldwide
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
All orders are subject to product availability. See our T&Cs.
Ask our team
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
| Specification | Description |
|---|---|
| Part Number | MGN61523 |
| Manufacturer | Schneider |
| Product or Component Type | Miniature circuit-breaker |
| Range | Multi 9 |
| Device Short Name | C60H-DC |
| Device Application | Distribution |
| Poles Description | 2P |
| Number of Protected Poles | 2 |
| Line Rated Current | 3 A at 25 °C |
| Network Type | DC |
| Trip Unit Technology | Thermal-magnetic |
| Curve Code | C |
| Breaking Capacity | 5 kA at 500 V DC according to UL 1077 |
| Utilisation Category | Category A according to EN/IEC 60947-2 |
| Suitability for Isolation | Yes, according to EN/IEC 60947-2 |
| Rated Operational Voltage | 12...500 V DC |
| Magnetic Tripping Limit | 8.5 x In +/- 20% AC |
| Rated Service Breaking Capacity | 4.5 kA at 75% - 500 V DC |
| Limitation Class | 3 according to EN/IEC 60947-2 |
| Rated Insulation Voltage | 500 V DC according to EN/IEC 60947-2 |
| Rated Impulse Withstand Voltage | 6 kV according to EN/IEC 60947-2 |
| Contact Position Indicator | Yes |
| Control Type | Toggle |
| Local Signalling | ON/OFF indication |
| Mounting Mode | Clip-on |
| Mounting Support | DIN rail |
| Comb Busbar and Distribution Block Compatibility | Top or bottom standard |
| Maximum Height | 81 mm |
| Maximum Width | 36 mm |
| Maximum Depth | 73 mm |
| Net Weight | 0.256 kg |
| Colour | Grey |
| Mechanical Durability | 20000 cycles |
| Electrical Durability | 3000 cycles with L/R = 2 ms, 6000 cycles resistive |
| Provision for Padlocking | Padlockable |
| Connections - Terminals | Tunnel type terminal for various wire sizes and types |
| Wire Stripping Length | 14 mm |
| Tightening Torque | 2.5 N.m |
| Earth-leakage Protection | Without |
| Standards | UL 1077, GB 14048.2, EN/IEC 60947-2 |
| Product Certifications | UR, CCC, IEC |
| IP Degree of Protection | IP20 according to IEC 60529, IP40 in modular enclosure |
| Pollution Degree | 3 according to EN/IEC 60947-2 |
| Overvoltage Category | IV |
| Tropicalisation | 2 according to IEC 60068-2 and GB 14048.2 |
| Relative Humidity | 95% at 55 °C |
| Operating Altitude | Up to 2000 m |
| Ambient Air Temperature for Operation | -25 to 70 °C |
| Ambient Air Temperature for Storage | -40 to 85 °C |
The Schneider MGN61523 is a miniature circuit-breaker designed for protecting DC circuits from overcurrents, including short-circuit and overload conditions. It ensures safe operation and isolation of electrical equipment.
Yes, the Schneider MGN61523 is suitable for isolation according to EN/IEC 60947-2 standards, which means it can be used to ensure that a circuit is completely de-energised for service or maintenance.
The Schneider MGN61523 utilises thermal-magnetic trip unit technology, which provides protection against both thermal overloads and short-circuit or magnetic faults.
The rated operational voltage for the Schneider MGN61523 is 12 to 500 V DC, making it versatile for a range of DC applications.
The Schneider MGN61523 is designed for clip-on mounting on a DIN rail, which facilitates easy installation and removal. It also has compatibility with top or bottom comb busbar and distribution blocks.
The breaking capacity of the Schneider MGN61523 varies depending on the voltage level, with a capacity of 5 kA at 500 V DC according to UL 1077 and up to 20 kA at 220 V DC according to EN/IEC 60947-2.
The Schneider MGN61523 features a contact position indicator that allows for easy visual identification of whether the contacts are open or closed.
The dimensions of the Schneider MGN61523 are 81 mm in height, 36 mm in width, and 73 mm in depth, with a net weight of approximately 0.256 kg.
The Schneider MGN61523 has a mechanical durability of 20,000 cycles and an electrical durability of 3,000 cycles for applications with an L/R of 2 ms, and 6,000 cycles for resistive circuits.
Yes, the Schneider MGN61523 is padlockable, which allows for securing the device in the off position to prevent unauthorised or accidental switching.
This content has been produced using multiple sources. EU Automation takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
All parts new or reconditioned are covered by EU Automation 12 month warranty
No hassle returns policy
Dedicated customer support team
We understand that credit is a necessary part of business and offer credit agreements on request, subject to status.
Payment optionsWe accept Bank transfers and the following methods of payment:
All transactions are handled securely by HSBC and HSBC Merchant Services. For more information, please visit our dedicated payments page.
Global supplier of quality automation and control components
Dispose of your old unit by exchanging it for a working part.
A comprehensive repair service for faulty equipment.
You don’t need tights and a cape to be a hero.
Get parts fast and feel like a legend, just like Jeff.