steve
Got hold of Sime for a Carrier card for…
Got hold of Sime for a Carrier card for a chiller. Machine down in a factory. Received the new card in express time machine and plant now up and running fantastic service form Sime
3 months ago
Full 12-month warranty
Available for dispatch immediately
We deliver worldwide
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
All orders are subject to product availability. See our T&Cs.
Ask our team
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
| Specification | Description |
|---|---|
| Part Number | LV510307 |
| Manufacturer | Schneider |
| Product Type | Circuit Breaker |
| Range | EasyPact |
| Product Name | EasyPact CVS |
| Device Short Name | CVS100B |
| Application | Distribution |
| Poles Description | 3P |
| Protected Poles Description | 3D |
| Earth Leakage Protection | Without (Vigi add-on) |
| Rated Current [In] | 100 A at 40 °C |
| Network Type | AC |
| Utilisation Category | Category A |
| Breaking Capacity [Icu] | 40 kA at 220/240 V AC 50/60 Hz, 25 kA at 380/415 V AC 50/60 Hz, 20 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 |
| Trip Unit Name | TM-D |
| Trip Unit Technology | Thermal-magnetic |
| Trip Unit Rating | 100 A at 40 °C |
| Protection Type | Short-circuit protection (magnetic), Overload protection (thermal) |
| Rated Impulse Withstand Voltage [Uimp] | 8 kV conforming to EN/IEC 60947-2 |
| Network Frequency | 50/60 Hz |
| Breaking Capacity Code | B |
| Rated Service Breaking Capacity [Ics] | 15 kA at 440 V AC 50/60 Hz, 25 kA at 380/415 V AC 50/60 Hz, 40 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 |
| Mechanical Durability | 30,000 cycles |
| Electrical Durability | 12,000 cycles at 415 V In conforming to IEC 60947-2 |
| Control Type | Toggle |
| Thermal Protection Adjustment Range | 70…100 A |
| Long Time Pick-up Adjustment Type | Ir Adjustable |
| Long Time Pick-up Adjustment Range | 0.7...1 x In |
| Long Time Delay Adjustment Type | Fixed |
| Instantaneous Pick-up Adjustment Type | Ii Fixed |
| Instantaneous Pick-up Adjustment Range | 800 A |
| Contact Position Indicator | Yes |
| Mounting Mode | Fixed |
| Mounting Support | Backplate |
| Upside Connection | Front |
| Downside Connection | Front |
| Connections - Terminals | Screw connection |
| Connection Pitch | 35 mm |
| Compatibility Code | CVS100 |
| Width | 105 mm |
| Depth | 86 mm |
| Height | 161 mm |
| Net Weight | 1.8 kg |
| Standards | EN 60947-2, IEC 60947-2 |
| Product Certifications | GOST, IEC |
| Electrical Shock Protection Class | Class II |
| Pollution Degree | 3 conforming to IEC 60664-1 |
| IP Degree of Protection | IP40 |
| Ambient Air Temperature for Operation | -25…70 °C |
| Ambient Air Temperature for Storage | -50…85 °C |
| Sustainable Offer Status | Green Premium product |
| REACh Regulation | REACh Declaration |
| EU RoHS Directive | Compliant with Exemptions |
| Mercury Free | Yes |
| China RoHS Regulation | China RoHS Declaration |
| Environmental Disclosure | Product Environmental Profile |
| Circularity Profile | No need of specific recycling operations |
| WEEE | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins |
The Schneider LV510307 circuit breaker has a rated current of 100 A at 40 °C.
This circuit breaker provides both short-circuit protection (magnetic) and overload protection (thermal).
The breaking capacity is 40 kA at 220/240 V AC, 25 kA at 380/415 V AC, and 20 kA at 440 V AC, conforming to IEC 60947-2.
The mechanical durability of the Schneider LV510307 circuit breaker is 30,000 cycles.
The dimensions are 105 mm in width, 86 mm in depth, and 161 mm in height.
The circuit breaker has an IP40 degree of protection.
The ambient air temperature for operation ranges from -25 to 70 °C.
Yes, the Schneider LV510307 is a Green Premium product, compliant with REACh and RoHS regulations.
This circuit breaker is designed for fixed mounting on a backplate.
Yes, the Schneider LV510307 circuit breaker includes a contact position indicator.
This content has been produced using multiple sources. EU Automation takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
All parts new or reconditioned are covered by EU Automation 12 month warranty
No hassle returns policy
Dedicated customer support team
We understand that credit is a necessary part of business and offer credit agreements on request, subject to status.
Payment optionsWe accept Bank transfers and the following methods of payment:
All transactions are handled securely by HSBC and HSBC Merchant Services. For more information, please visit our dedicated payments page.
Global supplier of quality automation and control components
Dispose of your old unit by exchanging it for a working part.
A comprehensive repair service for faulty equipment.
You don’t need tights and a cape to be a hero.
Get parts fast and feel like a legend, just like Jeff.