steve
Got hold of Sime for a Carrier card for…
Got hold of Sime for a Carrier card for a chiller. Machine down in a factory. Received the new card in express time machine and plant now up and running fantastic service form Sime
3 months ago
Full 12-month warranty
Available for dispatch immediately
We deliver worldwide
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
All orders are subject to product availability. See our T&Cs.
Ask our team
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
| Specification | Description |
|---|---|
| Part Number | LUCM12BL |
| Manufacturer | Schneider Electric |
| Product Range | TeSys |
| Product Family | TeSys Ultra |
| Device Short Name | LUCM |
| Product or Component Type | Multifunction control unit |
| Device Application | Motor control and protection |
| Specific Application | Sophisticated control and protection requirements, with display |
| Product Compatibility | Compatible with various TeSys U bases and contactor breakers |
| Utilisation Category | AC-41, AC-43, AC-44 |
| Motor Power kW | 9 kW at 690 V AC 50/60 Hz, 5.5 kW at 400...440 V AC 50/60 Hz, 5.5 kW at 500 V AC 50/60 Hz |
| Thermal Protection Adjustment Range | 3...12 A |
| [Uc] Control Circuit Voltage | 24 V DC |
| Thermal Overload Class | Class 5…30, with temperature compensation and frequency limit |
| User Language | English (factory setting), English, French, German, Italian, Spanish (settable) |
| Mounting Mode | Plug-in |
| Mounting Location | Front side |
| Control Circuit Voltage Limits | 20...28 V DC in operation |
| Typical Current Consumption | 150 mA at 24 V DC maximum while closing with LUB12, 200 mA at 24 V DC maximum with LUB32 |
| Operating Time | 35 ms opening with LUB12 control circuit, 65 ms closing with LUB32 control circuit |
| Load Type | Single-phase and 3-phase motors, self-cooled or force cooled, settable |
| Tripping Threshold | 14.2 x Ir +/- 20% |
| Physical Interface | RS485 multidrop, RJ45 front panel, Modbus RTU 19200 bit/s |
| Reset | Automatic reset (settable), Manual (factory and settable), Remote reset (settable) |
| Information Displayed | Average current, cause of last 5 faults, current in phase, earth leakage current, and more |
| [Ui] Rated Insulation Voltage | 690 V conforming to IEC 60947-1, 600 V conforming to UL 508 and CSA C22.2 No 14 |
| [Uimp] Rated Impulse Withstand Voltage | 6 kV conforming to IEC 60947-6-2 |
| Product Weight | 0.175 kg |
The multifunction control unit is designed for sophisticated control and protection of motors, offering features such as protection against overload and short-circuit, manual or automatic reset, alarm functions, protection against phase failure and imbalance, a log function, and monitoring of main motor parameters.
Yes, the multifunction control unit can be configured to work with single-phase motors, as well as three-phase motors, providing versatile application options.
The thermal protection adjustment range for the LUCM12BL is from 3 to 12 amperes, allowing for customisation based on the motor's requirements.
The unit is compatible with both self-cooled and force-cooled motors, and it can be set accordingly to match the motor type in use.
The unit's display can be set in multiple languages, including English, French, German, Italian, and Spanish, making it user-friendly for a wide range of operators.
The control circuit voltage for the unit is 24 V DC, which is standard for many control systems.
The unit has built-in protection functions that detect phase failure and phase imbalance, ensuring the motor is safeguarded against such electrical issues.
The unit has an IP20 degree of protection for the front panel and wired terminals, and IP40 for the front panel outside the connection zone, providing a degree of protection against solid objects.
Yes, the unit features an RS485 multidrop physical interface with an RJ45 connector on the front panel, supporting Modbus RTU communication protocol at 19200 bit/s.
The unit can be reset manually, automatically, or remotely, with the time before reset being factory set at 120 seconds or adjustable between 1 to 1000 seconds.
This content has been produced using multiple sources. EU Automation takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
All parts new or reconditioned are covered by EU Automation 12 month warranty
No hassle returns policy
Dedicated customer support team
We understand that credit is a necessary part of business and offer credit agreements on request, subject to status.
Payment optionsWe accept Bank transfers and the following methods of payment:
All transactions are handled securely by HSBC and HSBC Merchant Services. For more information, please visit our dedicated payments page.
Global supplier of quality automation and control components
Dispose of your old unit by exchanging it for a working part.
A comprehensive repair service for faulty equipment.
You don’t need tights and a cape to be a hero.
Get parts fast and feel like a legend, just like Jeff.