steve
Got hold of Sime for a Carrier card for…
Got hold of Sime for a Carrier card for a chiller. Machine down in a factory. Received the new card in express time machine and plant now up and running fantastic service form Sime
4 weeks ago
Full 12-month warranty
Available for dispatch immediately
We deliver worldwide
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
All orders are subject to product availability. See our T&Cs.
Ask our team
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
| Specification | Description |
|---|---|
| Part Number | LRD32 |
| Manufacturer | Schneider |
| Product Type | Thermal Overload Relay |
| Mounting Type | DIN Rail Mount |
| Width | 45 mm |
| Depth | 70 mm |
| Network Type | AC/DC |
| Thermal Overload Class | Class 10A conforming to IEC 60947-4-1 |
| Thermal Protection Range | 23 to 32 A |
| Rated Insulation Voltage | 690 V ac |
| Network Frequency | 0 to 400 Hz |
| Auxiliary Contact Composition | 1 Normally Open (NO) + 1 Normally Closed (NC) |
| Operational Voltage | 690 V ac 0 to 400 Hz for power circuit conforming to IEC 60947-4-1 |
| Tightening Torque | Control circuit: 1.7 N.m - on screw clamp terminals, Power circuit: 2.5 N.m - on screw clamp terminals |
| Height | 66 mm |
| Net Weight | 0.124 kg |
| IP Degree of Protection | IP20 conforming to IEC 60529 |
| Ambient Operating Temperature | -20 to 60 °C without derating conforming to IEC 60947-4-1 |
| Ambient Storage Temperature | -60 to 70 °C |
| Flame Retardance | V1 conforming to UL 94 |
| Mechanical Robustness | Vibrations: 6 Gn conforming to IEC 60068-2-6, Shocks: 15 Gn for 11 ms conforming to IEC 60068-2-7 |
| Dielectric Strength | 1.89 kV at 50 Hz conforming to IEC 60947-1 |
| Standards | EN/IEC 60947-4-1, EN/IEC 60947-5-1, UL 60947-4-1, UL 60947-5-1, CSA C22.2 No 60947-4-1, CSA C22.2 No 60947-5-1 |
| Product Certifications | IEC, UL, CSA, CCC, EAC, BV, RINA, DNV-GL, LROS, ATEX INERIS, UKCA |
| Sustainable Offer Status | Green Premium product |
| REACh Regulation | REACh Declaration |
| EU RoHS Directive | Compliant with Exemptions |
| Mercury Free | Yes |
| China RoHS Regulation | China RoHS Declaration |
| Environmental Disclosure | Product Environmental Profile |
The LRD32 thermal overload relay is primarily used for motor protection. It's designed to protect motors from overheating by monitoring the current flow and disconnecting the power when the current exceeds a preset level.
The thermal protection adjustment range of the LRD32 is 23 to 32 Amps. This means it can be set to trip at any current level within this range.
The LRD32 relay offers versatile mounting options. It can be mounted on a plate with specific accessories, on a rail with specific accessories, or under a contactor.
The LRD32 has a rated insulation voltage of 690 V AC according to IEC 60947-4-1. This is the maximum voltage the relay can withstand without risk of electrical breakdown.
The LRD32 can operate within a network frequency range of 0 to 400 Hz. This makes it suitable for use in a wide range of power systems.
The LRD32 relay has an auxiliary contact composition of 1 Normally Open (NO) + 1 Normally Closed (NC). This allows for flexible control and signalling options.
The LRD32 has a tripping threshold of 1.14 +/- 0.06 Ir according to IEC 60947-4-1. This means it will trip when the current reaches 114% to 106% of the set level.
The LRD32 relay has a phase failure sensitivity feature. It will trip when the current reaches 130% of Ir on two phases, with the last one at 0.
The LRD32 relay offers temperature compensation from -20 to 60 degrees Celsius. This means it can operate reliably within this temperature range without derating.
The control circuit of the LRD32 requires a tightening torque of 1.7 N.m on screw clamp terminals, while the power circuit requires 2.5 N.m on screw clamp terminals.
This content has been produced using multiple sources. EU Automation takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
All parts new or reconditioned are covered by EU Automation 12 month warranty
No hassle returns policy
Dedicated customer support team
We understand that credit is a necessary part of business and offer credit agreements on request, subject to status.
Payment optionsWe accept Bank transfers and the following methods of payment:
All transactions are handled securely by HSBC and HSBC Merchant Services. For more information, please visit our dedicated payments page.
Global supplier of quality automation and control components
Dispose of your old unit by exchanging it for a working part.
A comprehensive repair service for faulty equipment.
You don’t need tights and a cape to be a hero.
Get parts fast and feel like a legend, just like Jeff.