steve
Got hold of Sime for a Carrier card for…
Got hold of Sime for a Carrier card for a chiller. Machine down in a factory. Received the new card in express time machine and plant now up and running fantastic service form Sime
3 months ago
Full 12-month warranty
Available for dispatch immediately
We deliver worldwide
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
All orders are subject to product availability. See our T&Cs.
Ask our team
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
| Specification | Description |
|---|---|
| Manufacturer | Schneider Electric |
| Part Number | LRD226 |
| Product Range | TeSys Deca |
| Product Type | Differential thermal overload relay |
| Application | Motor overload and phase-loss protection |
| Thermal Adjustment Range | 16–24 A |
| Trip Class | Class 10A per IEC 60947-4-1 |
| Compatible Contactors | LC1D25, LC1D32, and LC1D38 |
| Network Type | AC or DC |
| Network Frequency | 0–400 Hz |
| Rated Operational Voltage | Up to 690 V AC |
| Rated Insulation Voltage | 690 V per IEC; 600 V per UL and CSA |
| Rated Impulse Withstand Voltage | 6 kV |
| Tripping Threshold | 1.14 ± 0.06 times the selected current setting |
| Phase-Failure Sensitivity | Trips at 130% of the current setting on two energized phases with the third phase at zero |
| Auxiliary Contacts | 1 normally open and 1 normally closed |
| Auxiliary Contact Thermal Current | 5 A |
| Signaling Circuit Rating | 1.5 A at 240 V AC-15; 0.1 A at 250 V DC-13 |
| Control Functions | Red stop push button and blue reset push button |
| Mounting Options | Directly beneath a compatible contactor; plate or rail mounting with suitable accessories |
| Power Connections | Ring-lug terminals with M4 fasteners |
| Control Connections | Screw-clamp terminals for 1–2.5 mm² flexible or solid conductors |
| Control Terminal Tightening Torque | 1.7 N·m |
| Power Terminal Tightening Torque | 2.3 N·m |
| Operating Temperature | -4 to 140°F (-20 to 60°C) without derating |
| Storage Temperature | -76 to 158°F (-60 to 70°C) |
| Degree of Protection | IP20 |
| Dimensions | 2.60 × 1.77 × 2.76 in (66 × 45 × 70 mm) |
| Net Weight | 0.27 lb (0.124 kg) |
| Applicable Standards | IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-4-1, UL 60947-5-1, CSA C22.2 No. 60947-4-1, CSA C22.2 No. 60947-5-1, GB/T 14048.4, GB/T 14048.5, and EN 50495 |
| Compliance | EU RoHS compliant, REACH SVHC-free, mercury-free, and WEEE regulated |
| Country of Origin | France |
This is a TeSys Deca differential thermal overload relay designed to protect electric motors against overload conditions and phase failure.
The thermal protection setting can be adjusted from 16 A to 24 A, allowing the relay to be matched to the motor's rated current.
The relay has a Class 10A tripping characteristic in accordance with IEC 60947-4-1.
The LRD226 is compatible with Schneider TeSys contactors including the LC1D25, LC1D32, and LC1D38.
Yes. It has phase-failure sensitivity and is designed to trip when an imbalance caused by a missing phase reaches the specified threshold.
The relay includes one normally open contact and one normally closed contact for use in control and signaling circuits.
It has a red stop push button and a blue reset push button for local operation.
It can be mounted directly beneath a compatible contactor. Plate and rail mounting are also possible when the appropriate accessories are used.
The relay operates without derating at ambient temperatures from -20°C to 60°C (-4°F to 140°F). Its specified storage temperature range is -60°C to 70°C (-76°F to 158°F).
The device has an IP20 protection rating in accordance with IEC 60529.
The unit measures approximately 66 mm high, 45 mm wide, and 70 mm deep.
The net weight is approximately 0.124 kg, equivalent to about 0.27 lb.
The relay is suitable for AC and DC networks, with a specified frequency range of 0 to 400 Hz.
The power circuit has a rated insulation voltage of 690 V under IEC requirements and 600 V under UL and CSA requirements.
The control circuit uses screw-clamp terminals that accept 1 to 2.5 mm² conductors. The power circuit uses M4 ring-lug terminals.
The specified tightening torque is 1.7 N·m for the control-circuit screw-clamp terminals and 2.3 N·m for the M4 power-circuit ring-lug terminals.
Yes. The LRD226 includes temperature compensation across its specified operating range to help maintain consistent overload protection.
The relay conforms to applicable IEC, EN, UL, CSA, and GB/T standards for motor control and electromechanical control-circuit devices, including IEC 60947-4-1 and IEC 60947-5-1.
This content has been produced using multiple sources. EU Automation takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
All parts new or reconditioned are covered by EU Automation 12 month warranty
No hassle returns policy
Dedicated customer support team
We understand that credit is a necessary part of business and offer credit agreements on request, subject to status.
Payment optionsWe accept Bank transfers and the following methods of payment:
All transactions are handled securely by HSBC and HSBC Merchant Services. For more information, please visit our dedicated payments page.
Global supplier of quality automation and control components
Dispose of your old unit by exchanging it for a working part.
A comprehensive repair service for faulty equipment.
You don’t need tights and a cape to be a hero.
Get parts fast and feel like a legend, just like Jeff.