steve
Got hold of Sime for a Carrier card for…
Got hold of Sime for a Carrier card for a chiller. Machine down in a factory. Received the new card in express time machine and plant now up and running fantastic service form Sime
3 months ago
Full 12-month warranty
Available for dispatch immediately
We deliver worldwide
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
All orders are subject to product availability. See our T&Cs.
Ask our team
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
| Specification | Description |
|---|---|
| Manufacturer | Schneider Electric |
| Part Number | LRD083 |
| Product Range | TeSys Deca |
| Product Type | Differential thermal overload relay |
| Application | Motor overload and phase-failure protection |
| Adjustment Range | 2.5–4 A |
| Trip Class | Class 10A, conforming to IEC 60947-4-1 |
| Compatible Contactors | LC1D09, LC1D12, LC1D18, LC1D25, LC1D32 and LC1D38 |
| Network Type | AC and DC |
| Network Frequency | 0–400 Hz |
| Rated Operational Voltage | 690 V AC, 0–400 Hz, for the power circuit |
| Rated Insulation Voltage | 690 V to IEC 60947-4-1; 600 V to UL and CSA |
| Rated Impulse Withstand Voltage | 6 kV |
| Trip Threshold | 1.14 ± 0.06 × Ir |
| Phase-Failure Sensitivity | Trips at 130% of Ir on two phases when the third phase is at zero |
| Auxiliary Contacts | 1 normally open and 1 normally closed |
| Conventional Free-Air Thermal Current | 5 A for the signalling circuit |
| Permissible Signalling Current | 3 A at 120 V AC-15; 0.22 A at 125 V DC-13 |
| Associated Fuse Rating | 4 A gG or 4 A BS for the signalling circuit |
| Controls | Red stop push-button and blue reset push-button |
| Terminal Type | Spring terminals |
| Control Circuit Connections | One 1–2.5 mm² solid or flexible conductor without cable end |
| Power Circuit Connections | One 1.5–4 mm² flexible conductor, with or without cable end |
| Mounting | Directly beneath a compatible contactor; plate or rail mounting with suitable accessories |
| Degree of Protection | IP20 to IEC 60529 |
| Operating Temperature | −20 to 60 °C without derating |
| Storage Temperature | −60 to 70 °C |
| Temperature Compensation | −20 to 60 °C |
| Flame Retardance | UL 94 V-1 |
| Vibration Resistance | 6 Gn to IEC 60068-2-6 |
| Shock Resistance | 15 Gn for 11 ms to IEC 60068-2-7 |
| Dielectric Strength | 1.89 kV at 50 Hz to IEC 60947-1 |
| Dimensions | 93 mm high × 45 mm wide × 72 mm deep |
| Net Weight | 0.14 kg |
| Key Standards | EN/IEC 60947-4-1, EN/IEC 60947-5-1, UL 60947-4-1, UL 60947-5-1 and EN 50495 |
| Certifications | IEC, UL, CSA, CCC, EAC, BV, RINA, DNV-GL, Lloyd’s Register, ATEX INERIS and UKCA |
The LRD083 is a TeSys Deca differential thermal overload relay designed to protect electric motors against sustained overloads and phase failure.
The thermal protection setting can be adjusted from 2.5 A to 4 A, allowing it to be matched to the motor's rated current.
This relay has a Class 10A trip characteristic in accordance with IEC 60947-4-1.
It is compatible with Schneider TeSys contactor models LC1D09, LC1D12, LC1D18, LC1D25, LC1D32 and LC1D38.
Yes. The relay is specified for use with both AC and DC network types, with an operating frequency range of 0 to 400 Hz.
The relay includes one normally open contact and one normally closed contact, identified as a 1 NO + 1 NC auxiliary contact arrangement.
A blue reset push-button is provided on the unit. It also has a red stop push-button for manual operation.
Yes. The LRD083 has phase-failure sensitivity and is specified to trip at 130% of the current setting on two phases when the remaining phase is at zero.
It uses spring terminals. The control circuit accepts one solid or flexible conductor from 1 to 2.5 mm², while the power circuit accepts one flexible conductor from 1.5 to 4 mm².
The power circuit has a rated operational voltage of up to 690 V AC at frequencies from 0 to 400 Hz, in accordance with IEC 60947-4-1.
The relay is designed to operate from -20°C to 60°C without derating. Its specified storage temperature range is -60°C to 70°C.
The component has an IP20 ingress protection rating in accordance with IEC 60529.
The unit measures approximately 93 mm high, 45 mm wide and 72 mm deep, with a net weight of about 0.14 kg.
It can be fitted directly beneath a compatible contactor. Plate and rail installation are also possible when the appropriate accessories are used.
The relay is designed in accordance with relevant standards including EN/IEC 60947-4-1, EN/IEC 60947-5-1, UL 60947-4-1, UL 60947-5-1 and applicable CSA standards.
This content has been produced using multiple sources. EU Automation takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
All parts new or reconditioned are covered by EU Automation 12 month warranty
No hassle returns policy
Dedicated customer support team
We understand that credit is a necessary part of business and offer credit agreements on request, subject to status.
Payment optionsWe accept Bank transfers and the following methods of payment:
All transactions are handled securely by HSBC and HSBC Merchant Services. For more information, please visit our dedicated payments page.
Global supplier of quality automation and control components
Dispose of your old unit by exchanging it for a working part.
A comprehensive repair service for faulty equipment.
You don’t need tights and a cape to be a hero.
Get parts fast and feel like a legend, just like Jeff.