steve
Got hold of Sime for a Carrier card for…
Got hold of Sime for a Carrier card for a chiller. Machine down in a factory. Received the new card in express time machine and plant now up and running fantastic service form Sime
3 months ago
Full 12-month warranty
Available for dispatch immediately
We deliver worldwide
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
All orders are subject to product availability. See our T&Cs.
Ask our team
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
| Specification | Description |
|---|---|
| Part Number | LR2K0301 |
| Manufacturer | Schneider |
| Product Range | TeSys |
| Product Name | TeSys LRK |
| Product Type | Differential Thermal Overload Relay |
| Device Short Name | LR2K |
| Relay Application | Motor Protection |
| Product Compatibility | Compatible with LC1K, LP1K, LC7K, LP4K |
| Network Type | AC, DC |
| Thermal Overload Class | Class 10A conforming to IEC 60947-4-1 |
| Thermal Protection Adjustment | 0.11...0.16 A |
| Rated Insulation Voltage | 690 V power circuit conforming to BS 4941, IEC 60947; 750 V power circuit conforming to VDE 0110 group C; 600 V power circuit conforming to CSA C22.2 No 14 |
| Network Frequency | ≤ 400 Hz |
| Mounting Support | Plate with specific accessories, Rail with specific accessories, Under contactor |
| Auxiliary Contact Composition | 1 NO + 1 NC |
| Conventional Free Air Thermal Current | 6 A for signalling circuit |
| Rated Operational Voltage | ≤ 690 V for power circuit; 690 V AC AC-15 for signalling circuit; 250 V DC DC-13 for signalling circuit |
| Associated Fuse Rating | 6 A gG for signalling circuit conforming to VDE 0660, IEC 60947 |
| Rated Impulse Withstand Voltage | 6 kV |
| Power Dissipation per Pole | 2 W |
| Phase Failure Sensitivity | Yes, conforming to IEC 60947-4-1 |
| Local Signalling | Trip indicator (yellow) |
| Control Type | Selector switch manual or automatic reset mode, Red push-button trip test function, Blue push-button stop and manual reset |
| Connections - Terminals | Screw clamp terminals for various cable stiffness and sizes |
| Tightening Torque | 11.5 lbf.in (1.3 N.m) on screw clamp terminals with screwdriver Philips No 2 or flat Ø 6 mm |
| Dimensions (H x W x D) | 58 mm x 45 mm x 65 mm |
| Product Weight | 0.145 kg |
| Environmental Standards | Conforms to VDE 0660, IEC 60947, NF C 63-650, BS 4941 |
| Product Certifications | UL, CSA |
| IP Degree of Protection | IP2x conforming to IEC 60529 |
| Ambient Air Temperature for Operation | -20...55 °C without derating, -30...60 °C with derating conforming to IEC 60947 |
| Ambient Air Temperature for Storage | -40...70 °C |
| Operating Altitude | 2000 m without derating |
| Fire Resistance | 850 °C conforming to IEC 60695-2-1 |
| Flame Retardance | V1 conforming to UL 94, Requirement 2 conforming to NF F 16-101, NF F 16-102 |
| Mechanical Robustness | Shocks NO/NC contact 10 Gn for 11 ms, Vibrations NO/NC contact 2 Gn, 5...300 Hz conforming to IEC 60068-2-27, IEC 60068-2-6 |
| Sustainable Offer Status | Green Premium product |
| California Proposition 65 | WARNING: This product can expose you to chemicals including Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov |
The primary function of this thermal overload relay is to provide motor protection by preventing overheating, which can cause damage to the motor.
The thermal protection adjustment range for this relay is 0.11 to 0.16 A.
This relay is compatible with both AC and DC network types.
The rated insulation voltage for this relay is 690 V for the power circuit, conforming to IEC 60947.
The dimensions of this thermal overload relay are 58 mm in height, 45 mm in width, and 65 mm in depth.
The IP degree of protection for this relay is IP2X, conforming to IEC 60529.
The ambient air temperature range for operation is -20 to 55 °C without derating, and -30 to 60 °C with derating, conforming to IEC 60947.
Yes, this relay has phase failure sensitivity conforming to IEC 60947-4-1.
This relay can be mounted under a contactor, on a plate with specific accessories, or on a rail with specific accessories.
The control types available for this relay include a red push-button for trip test function, a blue push-button for stop and manual reset, and a selector switch for manual or automatic reset.
This content has been produced using multiple sources. EU Automation takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
All parts new or reconditioned are covered by EU Automation 12 month warranty
No hassle returns policy
Dedicated customer support team
We understand that credit is a necessary part of business and offer credit agreements on request, subject to status.
Payment optionsWe accept Bank transfers and the following methods of payment:
All transactions are handled securely by HSBC and HSBC Merchant Services. For more information, please visit our dedicated payments page.
Global supplier of quality automation and control components
Dispose of your old unit by exchanging it for a working part.
A comprehensive repair service for faulty equipment.
You don’t need tights and a cape to be a hero.
Get parts fast and feel like a legend, just like Jeff.