steve
Got hold of Sime for a Carrier card for…
Got hold of Sime for a Carrier card for a chiller. Machine down in a factory. Received the new card in express time machine and plant now up and running fantastic service form Sime
3 months ago
Full 12-month warranty
Available for dispatch immediately
We deliver worldwide
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
All orders are subject to product availability. See our T&Cs.
Ask our team
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
| Specification | Description |
|---|---|
| Manufacturer | Schneider Electric |
| Part number | LR2D3561 |
| Product range | TeSys |
| Product type | Differential thermal overload relay |
| Primary application | Motor protection (thermal overload and phase-loss detection) |
| Thermal overload class | Class 20 (IEC 60947-4-1) |
| Current setting range (Ir) | Adjustable 55…70 A |
| Tripping threshold | 1.14 ± 0.06 × Ir (IEC 60947-4-1) |
| Phase failure sensitivity | Trips at 130% of Ir on two phases, with the remaining phase at 0 |
| Compatible contactors | TeSys D LC1D80, LC1D95 |
| Supply / network type | AC and DC systems |
| Network frequency | 0…400 Hz |
| Rated insulation voltage (Ui) | 600 V (UL/CSA power circuit); 690 V (IEC 60947-4-1 power circuit) |
| Rated operational voltage (Ue) | Up to 1000 V AC, 0…400 Hz (power circuit, IEC 60947-4-1) |
| Impulse withstand voltage (Uimp) | 6 kV |
| Auxiliary contact configuration | 1 NO + 1 NC |
| Conventional thermal current (Ith) | 5 A (signalling circuit) |
| Signalling circuit rating (AC-15) | 0.72 A at 500 V |
| Signalling circuit rating (DC-13) | 0.06 A at 440 V |
| Associated fuse rating (signalling) | 4 A gG; 4 A BS |
| Reset / control interface | Red stop push-button; blue reset push-button |
| Temperature compensation | -20…60 °C |
| Mounting options | Under contactor; rail or plate mounting with specific accessories |
| Power terminals | Screw clamp, 1 conductor: 4…35 mm² (solid or flexible, with/without ferrule) |
| Control terminals | Screw clamp, 2 conductors: 1…2.5 mm² (solid or flexible, with/without ferrule) |
| Tightening torque | Power: 9 N·m; Control: 1.7 N·m |
| IP rating | IP20 (IEC 60529) |
| Operating ambient temperature | -20…60 °C (without derating) |
| Storage temperature | -60…70 °C |
| Protective treatment | TH (IEC 60068) |
| Flame retardance | UL 94 V1 |
| Mechanical robustness | Vibrations: 6 Gn (IEC 60068-2-6); Shocks: 15 Gn for 11 ms (IEC 60068-2-7) |
| Standards | IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 508, CSA C22.2 No 14 (as applicable) |
| Dimensions (H × W × D) | 100 × 75 × 121 mm |
| Net weight | 0.535 kg |
| Part description (website) | Schneider LR2D3561 is an adjustable TeSys thermal overload relay designed for dependable motor protection, with a 55–70 A setting range and Class 20 tripping. It pairs with TeSys D contactors (LC1D80/LC1D95), includes phase-loss sensitivity to help protect three‑phase motors, and provides 1NO+1NC auxiliary contacts for straightforward control and signalling integration. |
It provides motor overload and phase-loss protection by monitoring current through the motor and tripping when an overload condition is detected, helping to prevent overheating damage. This device is a differential thermal overload relay (LR2D3561).
The adjustable thermal protection setting range is 55 to 70 A, allowing you to match the trip setting to the motor’s rated current.
It is Class 20 (IEC 60947-4-1), which is typically selected for motors with higher starting times or heavier starting loads where a longer permissible start duration is required compared with faster trip classes.
It is specified as compatible with LC1D80 and LC1D95 contactors, commonly used in TeSys D motor starter assemblies.
Yes. It is designed for AC and DC network types, making it suitable for a wide range of motor control panels.
It supports 0 to 400 Hz, which covers standard mains applications and many variable-frequency drive (VFD) output scenarios.
It includes phase failure sensitivity: it trips when two phases carry approximately 130% of the set current (Ir) while the remaining phase is at 0, helping protect the motor during single-phasing conditions.
It includes 1 normally open (NO) and 1 normally closed (NC) auxiliary contact for status indication and interlocking in control circuits.
For signalling circuits, permissible current is 0.72 A at 500 V AC-15 and 0.06 A at 440 V DC-13. The conventional free-air thermal current (Ith) for the signalling circuit is 5 A.
Key ratings include: rated insulation voltage (Ui) up to 690 V (IEC) for the power circuit, and an impulse withstand voltage (Uimp) of 6 kV. The rated operational voltage (Ue) for the power circuit is specified up to 1000 V AC (0–400 Hz) in the latest product data.
It can be mounted under a compatible contactor, or on a plate or rail when used with the appropriate accessories, giving flexibility for motor control panel layouts.
Power circuit screw clamp terminals accept 4 to 35 mm² (solid or flexible, with or without cable end). Control circuit screw clamp terminals accept 1 to 2.5 mm² (solid or flexible, with or without cable end).
Typical tightening torques are 9 N·m for the power terminals and 1.7 N·m for the control terminals.
Approximate dimensions are 100 mm (H) × 75 mm (W) × 121 mm (D), with a net weight around 0.535 kg.
It is rated for operation from -20 to +60 °C without derating and storage from -60 to +70 °C. The ingress protection rating is IP20, so it is intended for installation inside an appropriate enclosure.
This content has been produced using multiple sources. EU Automation takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
All parts new or reconditioned are covered by EU Automation 12 month warranty
No hassle returns policy
Dedicated customer support team
We understand that credit is a necessary part of business and offer credit agreements on request, subject to status.
Payment optionsWe accept Bank transfers and the following methods of payment:
All transactions are handled securely by HSBC and HSBC Merchant Services. For more information, please visit our dedicated payments page.
Global supplier of quality automation and control components
Dispose of your old unit by exchanging it for a working part.
A comprehensive repair service for faulty equipment.
You don’t need tights and a cape to be a hero.
Get parts fast and feel like a legend, just like Jeff.