steve
Got hold of Sime for a Carrier card for…
Got hold of Sime for a Carrier card for a chiller. Machine down in a factory. Received the new card in express time machine and plant now up and running fantastic service form Sime
3 months ago
Full 12-month warranty
Available for dispatch immediately
We deliver worldwide
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
All orders are subject to product availability. See our T&Cs.
Ask our team
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
| Specification | Description |
|---|---|
| Part Number | LR2D3559 |
| Manufacturer | Schneider |
| Product Type | Thermal Overload Relay |
| Application | Motor Protection |
| Compatibility | LC1D80, LC1D95 |
| Network Type | AC, DC |
| Thermal Overload Class | Class 20 conforming to IEC 60947-4-1 |
| Thermal Protection Adjustment Range | 48...65 A |
| Rated Insulation Voltage ([Ui]) | 690 V AC power circuit conforming to IEC 60947-4-1, 600 V AC power circuit conforming to UL |
| Network Frequency | 0...400 Hz |
| Mounting Support | Plate with specific accessories, Rail with specific accessories, Under contactor |
| Tripping Threshold | 1.14 +/- 0.06 Ir conforming to IEC 60947-4-1 |
| Auxiliary Contact Composition | 1 NO + 1 NC |
| Conventional Free Air Thermal Current ([Ith]) | 5 A for signalling circuit |
| Permissible Current | 0.72 A at 500 V AC-15 for signalling circuit, 0.06 A at 440 V DC-13 for signalling circuit |
| Rated Operational Voltage ([Ue]) | 690 V AC 0...400 Hz |
| Rated Impulse Withstand Voltage ([Uimp]) | 6 kV |
| Phase Failure Sensitivity | Tripping current 130 % of Ir on two phase, the last one at 0 |
| Control Type | Red push-button stop, Blue push-button reset |
| Temperature Compensation | -20...60 °C |
| Connections - Terminals | Screw clamp terminals for power and control circuits with various cable flexibility options |
| Tightening Torque | Control circuit: 1.7 N.m, Power circuit: 9 N.m |
| Dimensions (Height x Width x Depth) | 100 mm x 75 mm x 121 mm |
| Product Weight | 0.535 kg |
A thermal overload relay is designed to protect electric motors from overheating, caused by excessive current draw, prolonged motor stall, or a loss of phase. It works by measuring the heat generated by the current and tripping the circuit when the temperature exceeds a preset limit, thus preventing potential damage to the motor.
The thermal protection range on the relay can be adjusted by turning the dial located on the front of the unit. This allows you to set the correct current range to match the motor's requirements, ensuring reliable protection against overload conditions.
Yes, the relay is compatible with both AC and DC power circuits, making it versatile for use in various applications and network types.
The 1NO + 1NC auxiliary contact composition means that the relay includes one Normally Open (NO) and one Normally Closed (NC) contact. These contacts can be used for signaling and control purposes, such as indicating the status of the relay or controlling auxiliary circuits.
The class 20 designation refers to the tripping characteristic of the thermal overload relay. It indicates that the relay will trip or activate within a time frame that is standard for class 20 relays when the current reaches 20% above the relay's rated current.
Phase failure sensitivity in the relay ensures protection against phase loss, which can be harmful to motors. If one of the phases fails or the current drops to a certain level, the relay will detect the imbalance and disconnect the motor to prevent damage.
The temperature compensation feature allows the relay to maintain consistent protection performance over a specified temperature range. This means that the relay will not trip unnecessarily due to ambient temperature changes, ensuring reliable motor protection.
The relay is equipped with a red stop push-button and a blue reset push-button. If the relay has tripped due to an overload, the red button will pop out, indicating that the relay has activated and the circuit is open. To reset the relay, simply press the blue button once the overload condition has been cleared.
The relay can be mounted using a plate with specific accessories, a rail with specific accessories, or directly under a contactor. This provides flexibility for installation in various types of control panels and motor starter configurations.
When selecting a fuse to use with the relay, ensure that the fuse rating is compatible with the signalling circuit requirements. The relay's associated fuse rating is typically 4A gG for the signalling circuit, which should be taken into account when choosing the appropriate fuse.
This content has been produced using multiple sources. EU Automation takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
All parts new or reconditioned are covered by EU Automation 12 month warranty
No hassle returns policy
Dedicated customer support team
We understand that credit is a necessary part of business and offer credit agreements on request, subject to status.
Payment optionsWe accept Bank transfers and the following methods of payment:
All transactions are handled securely by HSBC and HSBC Merchant Services. For more information, please visit our dedicated payments page.
Global supplier of quality automation and control components
Dispose of your old unit by exchanging it for a working part.
A comprehensive repair service for faulty equipment.
You don’t need tights and a cape to be a hero.
Get parts fast and feel like a legend, just like Jeff.