steve
Got hold of Sime for a Carrier card for…
Got hold of Sime for a Carrier card for a chiller. Machine down in a factory. Received the new card in express time machine and plant now up and running fantastic service form Sime
3 months ago
Full 12-month warranty
Available for dispatch immediately
We deliver worldwide
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
All orders are subject to product availability. See our T&Cs.
Ask our team
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
| Specification | Description |
|---|---|
| Part Number | LC1F150F7 |
| Manufacturer | Schneider Electric |
| Product Range | TeSys F |
| Product Type | Contactor |
| Application | Motor control, Resistive load |
| Utilisation Category | AC-1, AC-3 |
| Poles Description | 3P (3 Normally Open) |
| Rated Operational Voltage | ≤ 1000 V AC 50/60 Hz, ≤ 460 V DC |
| Rated Operational Current | 250 A (≤ 40 °C) at ≤ 440 V AC AC-1, 150 A (≤ 55 °C) at ≤ 440 V AC AC-3 |
| Motor Power | 40 kW at 220-230 V AC, 65 kW at 1000 V AC, 75 kW at 380-400 V AC, 80 kW at 415-440 V AC, 90 kW at 500 V AC, 100 kW at 660-690 V AC |
| Control Circuit Type | AC 40-400 Hz |
| Control Circuit Voltage | 110 V AC 40-400 Hz |
| Rated Impulse Withstand Voltage | 8 kV |
| Overvoltage Category | III |
| Conventional Free Air Thermal Current | 250 A at ≤ 40 °C |
| Rated Making Capacity | 1500 A AC conforming to IEC 60947-4-1 |
| Rated Breaking Capacity | 1200 kA conforming to IEC 60947-4-1 |
| Rated Short-Time Withstand Current | 1200 A ≤ 40 °C 10 s, 700 A ≤ 40 °C 30 s, 600 A ≤ 40 °C 1 min, 450 A ≤ 40 °C 3 min, 350 A ≤ 40 °C 10 min |
| Associated Fuse Rating | 160 A aM at ≤ 440 V, 250 A gG at ≤ 440 V |
| Average Impedance | 0.35 mOhm at 50 Hz - Ith 250 A |
| Rated Insulation Voltage | 1000 V conforming to IEC 60947-4-1, 1500 V conforming to VDE 0110 group C |
| Power Dissipation per Pole | 22 W AC-1, 8 W AC-3 |
| Mounting Support | Plate |
| Standards | EN 60947-1, EN 60947-4-1, IEC 60947-1, IEC 60947-4-1, JEM 1038 |
| Product Certifications | BV, CCC, CSA, DNV, GL, RINA, RMRoS |
| Connections - Terminals | Control circuit: screw clamp terminals 1-4 mm² flexible/solid, Power circuit: connector 120 mm², lugs-ring terminals 120 mm², bar 2 x (25 x 3 mm) |
| Tightening Torque | Control circuit: 1.2 N.m, Power circuit: 18 N.m |
| Operating Time | 23-35 ms closing, 5-15 ms opening |
| Mechanical Durability | 10 million cycles |
| Operating Rate | 2400 cycles/hour at ≤ 55 °C |
| Control Circuit Voltage Limits | 0.85-1.1 Uc at 55 °C operational 50/60 Hz, 0.35-0.55 Uc at 55 °C drop-out 50/60 Hz |
| Inrush Power in VA | 550 VA at 20 °C (cos ϕ 0.3) 50 Hz, 660 VA at 20 °C (cos ϕ 0.3) 60 Hz |
| Hold-in Power Consumption in VA | 45 VA at 20 °C (cos ϕ 0.3) 50 Hz, 55 VA at 20 °C (cos ϕ 0.3) 60 Hz |
| Heat Dissipation | 12-16 W |
| IP Degree of Protection | IP2x front face with shrouds (ordered separately) conforming to IEC 60529, VDE 0106 |
| Protective Treatment | TH |
| Ambient Air Temperature for Operation | -5 to 55 °C |
| Ambient Air Temperature for Storage | -60 to 80 °C |
| Permissible Ambient Air Temperature | -40 to 70 °C |
| Operating Altitude | 3000 m without derating in temperature |
| Mechanical Robustness | Vibrations contactor open 2 Gn, 5-300 Hz; Shocks contactor closed 15 Gn for 11 ms; Vibrations contactor closed 6 Gn, 5-300 Hz; Shocks contactor open 9 Gn for 11 ms |
| Dimensions (H x W x D) | 170 mm x 163.5 mm x 171 mm |
| Product Weight | 3.43 kg |
| Sustainable Offer Status | Green Premium product |
| RoHS | Compliant |
| REACh | Reference not containing SVHC above the threshold |
| Product Environmental Profile | Available |
| Product End of Life Instructions | Available |
The Schneider LC1F150F7 contactor is primarily used for motor control and resistive load applications.
The rated operational current is 250 A at <= 40 °C for AC-1 applications and 150 A at <= 55 °C for AC-3 applications.
The Schneider LC1F150F7 contactor has a rated operational voltage of up to 1000 V AC and 460 V DC.
The contactor measures 170 mm in height, 163.5 mm in width, and 171 mm in depth.
The control circuit voltage for the Schneider LC1F150F7 is 110 V AC, operating at 40 to 400 Hz.
The Schneider LC1F150F7 contactor has a mechanical durability of 10 million cycles.
The rated impulse withstand voltage for this contactor is 8 kV.
The Schneider LC1F150F7 contactor requires a plate for mounting support.
This contactor is certified by BV, CCC, CSA, DNV, GL, RINA, RMRoS, UL, and LROS.
The Schneider LC1F150F7 contactor has an IP2x degree of protection for the front face with shrouds, conforming to IEC 60529.
This content has been produced using multiple sources. EU Automation takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
All parts new or reconditioned are covered by EU Automation 12 month warranty
No hassle returns policy
Dedicated customer support team
We understand that credit is a necessary part of business and offer credit agreements on request, subject to status.
Payment optionsWe accept Bank transfers and the following methods of payment:
All transactions are handled securely by HSBC and HSBC Merchant Services. For more information, please visit our dedicated payments page.
Global supplier of quality automation and control components
Dispose of your old unit by exchanging it for a working part.
A comprehensive repair service for faulty equipment.
You don’t need tights and a cape to be a hero.
Get parts fast and feel like a legend, just like Jeff.