steve
Got hold of Sime for a Carrier card for…
Got hold of Sime for a Carrier card for a chiller. Machine down in a factory. Received the new card in express time machine and plant now up and running fantastic service form Sime
3 months ago
Full 12-month warranty
Available for dispatch immediately
We deliver worldwide
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
All orders are subject to product availability. See our T&Cs.
Ask our team
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
| Specification | Description |
|---|---|
| Part Number | LC1D12V7 |
| Manufacturer | Schneider |
| Type | Contactor |
| Poles | 3 Pole |
| Contact Composition | 3 Normally Open (NO) |
| Operational Voltage (Ue) | ≤ 690 V AC; ≤ 300 V DC for power circuit |
| Operational Current (Ie) | 12 A at ≤ 440 V AC AC-3 for power circuit |
| Motor Power kW (AC-3) | 7.5 kW at 500 V AC; 5.5 kW at 380...400 V AC; 3 kW at 220...230 V AC |
| Motor Power HP (UL / CSA) | 7.5 hp at 460/480 V AC; 3 hp at 230/240 V AC; 2 hp at 230/240 V AC for 1 phase motors |
| Control Circuit Type | AC 50/60 Hz |
| Control Circuit Voltage (Uc) | 400 V AC 50/60 Hz |
| Auxiliary Contact Composition | 1 NO + 1 NC |
| Rated Impulse Withstand Voltage (Uimp) | 6 kV conforming to IEC 60947 |
| Overvoltage Category | III |
| Coil Technology | Without built-in suppressor module |
| Inrush Power in VA | 70 VA at 20 °C (cos ϕ 0.75) |
| Hold-in Power Consumption in VA | 7.5 VA at 20 °C (cos ϕ 0.3) |
| Heat Dissipation | 2...3 W at 50/60 Hz |
| Auxiliary Contacts Type | Mechanically linked and mirror contact conforming to IEC standards |
| Signalling Circuit Frequency | 25...400 Hz |
| Minimum Switching Current | 5 mA for signalling circuit |
| Minimum Switching Voltage | 17 V for signalling circuit |
| Insulation Resistance | > 10 MOhm for signalling circuit |
| IP Degree of Protection | IP20 front face conforming to IEC 60529 |
| Ambient Air Temperature for Operation | -5...60 °C |
| Operating Altitude | 3000 m without derating |
| Fire Resistance | 850 °C conforming to IEC 60695-2-1 |
| Flame Retardance | V1 conforming to UL 94 |
| Mechanical Robustness | Vibrations and shocks resistance conforming to IEC standards |
| Dimensions (H x W x D) | 77 mm x 45 mm x 86 mm |
| Product Weight | 0.325 kg |
| Sustainable Offer Status | Green Premium product |
| RoHS Compliance | Compliant |
| REACh Compliance | Reference not containing SVHC above the threshold |
| Product Environmental Profile | Available |
| Product End of Life Instructions | Available |
The Schneider contactor is designed for motor control and resistive load applications. It is suitable for utilisation categories AC-3, AC-4, and AC-1, making it versatile for various industrial uses.
Yes, the contactor can handle rated operational voltages up to 690 V AC for power circuits and up to 300 V DC, accommodating a range of voltage systems.
The contactor has a rated operational current of 12 A at less than or equal to 60°C for AC-3 power circuits and 25 A for AC-1 power circuits.
The contactor can control motor power up to 7.5 kW at 500 V AC for AC-3 and up to 3.7 kW at 400 V AC for AC-4, among other ratings for different voltages.
The dimensions of the contactor are 77 mm in height, 45 mm in width, and 86 mm in depth, making it compact for its capabilities.
The coil voltage for the LC1D12V7 contactor is rated at 400 V AC 50/60 Hz.
The contactor is equipped with 1 Normally Open (NO) and 1 Normally Closed (NC) auxiliary contact.
The mechanical durability of the contactor is rated at 15 million cycles, indicating a long operational lifespan under mechanical load.
The contactor can operate in ambient air temperatures ranging from -5°C to 60°C and at altitudes up to 3000 m without derating.
Yes, the contactor is certified by several bodies including CSA, UL, and it conforms to IEC standards, ensuring compliance with international safety and quality requirements.
This content has been produced using multiple sources. EU Automation takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
All parts new or reconditioned are covered by EU Automation 12 month warranty
No hassle returns policy
Dedicated customer support team
We understand that credit is a necessary part of business and offer credit agreements on request, subject to status.
Payment optionsWe accept Bank transfers and the following methods of payment:
All transactions are handled securely by HSBC and HSBC Merchant Services. For more information, please visit our dedicated payments page.
Global supplier of quality automation and control components
Dispose of your old unit by exchanging it for a working part.
A comprehensive repair service for faulty equipment.
You don’t need tights and a cape to be a hero.
Get parts fast and feel like a legend, just like Jeff.