steve
Got hold of Sime for a Carrier card for…
Got hold of Sime for a Carrier card for a chiller. Machine down in a factory. Received the new card in express time machine and plant now up and running fantastic service form Sime
3 months ago
Full 12-month warranty
Available for dispatch immediately
We deliver worldwide
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
All orders are subject to product availability. See our T&Cs.
Ask our team
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
| Specification | Description |
|---|---|
| Part Number | LC1D123BL |
| Manufacturer | Schneider Electric |
| Product Range | TeSys Deca |
| Type | IEC Contactor |
| Utilisation Category | AC-3, AC-1, AC-4, AC-3e |
| Poles Description | 3 Pole, 3 NO (Normally Open) |
| Operational Voltage (Ue) | Power circuit <= 690 V AC 25...400 Hz, Power circuit <= 300 V DC |
| Operational Current (Ie) | 16 A at 140°F (60°C) AC-1 power circuit, 12 A at 140°F (60°C) AC-3 power circuit |
| Control Circuit Voltage (Uc) | 24 V DC |
| Motor Power kW | Up to 7.5 kW at various voltages in AC-3, Up to 3.7 kW at 400 V AC 50/60 Hz in AC-4 |
| Horse Power Rating | Up to 7.5 HP at 460/480 V at AC 50/60 Hz for 3 phase |
| Contact Composition | 3 NO |
| Coil Technology | Built-in bidirectional peak limiting diode suppressor |
| Operating Time | 65.45...88.55 ms closing, 20...30 ms opening |
| Mounting Support | Rail, Plate |
| Standards | IEC 60947-4-1, IEC 60947-5-1, UL 508, CSA C22.2 No 14 |
| Product Certifications | LROS, GL, UL, BV, CCC, CSA, RINA, GOST, DNV, UKCA |
| IP Degree of Protection | IP20 front face conforming to IEC 60529 |
| Ambient Operating Temperature | -40…140°F (-40…60°C), 140…158°F (60…70°C) with derating |
| Operating Altitude | 0...9842.52 ft (0...3000 m) |
| Fire Resistance | 1562°F (850°C) conforming to IEC 60695-2-1 |
| Flame Retardance | V1 conforming to UL 94 |
| Mechanical Robustness | Vibrations: contactor open 2 Gn, 5...300 Hz; contactor closed 4 Gn, 5...300 Hz |
| Dimensions (H x W x D) | 3.90 in (99 mm) x 1.77 in (45 mm) x 3.74 in (95 mm) |
| Net Weight | 1.07 lb(US) (0.485 kg) |
| Associated Fuse Rating | 10 A gG signalling circuit, 40 A gG <= 690 V type 1 power circuit, 25 A gG <= 690 V type 2 |
| Rated Insulation Voltage (Ui) | Power circuit 690 V, Signalling circuit 690 V |
| Rated Impulse Withstand Voltage (Uimp) | 6 kV IEC 60947 |
| Pollution Degree | 3 |
| Electrical Durability | 2 Mcycles for 12 A AC-3 <= 440 V |
| Power Dissipation Per Pole | 0.36 W for AC-3, 1.56 W for AC-1 |
The contactor is suitable for utilisation categories AC-3, AC-1, AC-4, and AC-3e, making it versatile for motor control and resistive load applications.
Yes, it is rated for power circuits up to 690 V AC at 25...400 Hz and up to 300 V DC, accommodating a range of power systems.
The dimensions are 3.90 inches in height, 1.77 inches in width, and 3.74 inches in depth, which is approximately 99 mm x 45 mm x 95 mm.
It is designed to withstand a wide range of environmental conditions, including temperatures from -40 to 140°F (-40 to 60°C) and altitudes up to 3000 meters.
The contactor features a low consumption 24 V DC control circuit with a built-in bidirectional peak limiting diode suppressor.
The rated operational current is 16 A for AC-1 power circuits and 12 A for AC-3 power circuits at 140°F (60°C).
It can be mounted on a rail or plate, providing flexibility for installation in various settings.
The contactor has an IP20 degree of protection for the front face, ensuring safety and reliability in its operation.
It holds several product certifications, including CSA, EN, IEC, UL, and others, confirming its compliance with international standards.
The contactor boasts a mechanical durability of 30 million cycles and an electrical durability of 2 million cycles for AC-3 operations at 440 V.
This content has been produced using multiple sources. EU Automation takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
All parts new or reconditioned are covered by EU Automation 12 month warranty
No hassle returns policy
Dedicated customer support team
We understand that credit is a necessary part of business and offer credit agreements on request, subject to status.
Payment optionsWe accept Bank transfers and the following methods of payment:
All transactions are handled securely by HSBC and HSBC Merchant Services. For more information, please visit our dedicated payments page.
Global supplier of quality automation and control components
Dispose of your old unit by exchanging it for a working part.
A comprehensive repair service for faulty equipment.
You don’t need tights and a cape to be a hero.
Get parts fast and feel like a legend, just like Jeff.