steve
Got hold of Sime for a Carrier card for…
Got hold of Sime for a Carrier card for a chiller. Machine down in a factory. Received the new card in express time machine and plant now up and running fantastic service form Sime
3 months ago
Full 12-month warranty
Available for dispatch immediately
We deliver worldwide
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
All orders are subject to product availability. See our T&Cs.
Ask our team
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
| Specification | Description |
|---|---|
| Part Number | LADR4 |
| Manufacturer | Schneider |
| Product Type | Time Delay Auxiliary Contact Block |
| Contact Composition | 1 Normally Open (NO) + 1 Normally Closed (NC) |
| Timer Type | Off Delay |
| Time Delay Range | 10 to 180 seconds |
| Rated Operational Voltage (Ue) | 690 V AC 25...400 Hz |
| Rated Insulation Voltage (Ui) | 690 V conforming to IEC 60947-5-1, 600 V - certifications UL, 600 V - certifications CSA |
| Conventional Free Air Thermal Current (Ith) | 10 A at 140 °F (60 °C) |
| Rated Operational Current (Ie) | 6 A at 120 V AC-15, 1.04 A at 690 V AC-15, 0.55 A at 125 V DC-13, 0.1 A at 600 V DC-13 |
| Irms Rated Making Capacity | 140 A at <= 690 V AC, 250 A at <= 690 V DC conforming to IEC 60947-5-1 |
| Permissible Short-Time Rating | 100 A at 60 °C for 1 s, 120 A at 60 °C for 500 ms, 140 A at 60 °C for 100 ms |
| Mechanical Durability | 5 Million cycles |
| Minimum Switching Current | 5 mA |
| Minimum Switching Voltage | 17 V |
| Non-Overlap Time | 1.5 ms on de-energisation and energisation with no overlap between NC and NO contacts |
| Insulation Resistance | > 10 MOhm |
| Connections - Terminals | Screw clamp terminals for cables 1…2.5 mm², flexible with or without cable end, and rigid |
| Tightening Torque | 1.7 N.m with screwdriver flat Ø 6 mm or Philips No 2 |
| Dimensions (Height x Width x Depth) | 48 mm x 44 mm x 61 mm |
| IP Degree of Protection | IP20 conforming to IEC 60529 |
| Ambient Air Temperature for Operation | -40…158 °F (-40…70 °C) |
| Ambient Air Temperature for Storage | -76…176 °F (-60…80 °C) |
| Operating Altitude | Up to 3000 m without derating |
| Environmental Characteristic | Normal environment |
| Protective Treatment | TH conforming to IEC 60068 |
| Sustainable Offer Status | Green Premium product |
| Compliance | REACh, EU RoHS Directive, China RoHS Regulation |
| Mercury Free | Yes |
| PVC Free | Yes |
| Product Disposal | Must be disposed of in accordance with European Union waste collection regulations |
The time delay auxiliary contact block is designed to provide an off delay timing function for control circuits. It delays the opening of its contacts for a set period after the power supply is turned off, allowing for various control and safety functions within an electrical circuit.
No, this contact block is specifically designed to be compatible with TeSys D, TeSys F contactors, and certain TeSys Deca models. It is important to check the range compatibility for proper integration.
The contact block is rated for a operational voltage of 690 V AC at frequencies between 25 to 400 Hz, and has a conventional free air thermal current rating of 10 A at 60°C.
The time delay range that can be set on this contact block is from 10 to 180 seconds, allowing for a wide range of timing functions to suit different applications.
The contact block has an IP20 degree of protection conforming to IEC 60529 and a protective treatment of TH conforming to IEC 60068, ensuring it is safeguarded against normal environmental conditions.
This contact block is equipped with screw clamp terminals that can accommodate cables ranging from 1 to 2.5 mm², both flexible with cable end and rigid types.
Yes, the contact block is compliant with the EU RoHS Directive, which restricts the use of certain hazardous substances in electrical and electronic equipment.
The recommended tightening torque for the terminals on this contact block is 1.7 N.m, ensuring a secure and reliable connection.
At the end of its life, the product must be disposed of following specific waste collection guidelines and should never end up in rubbish bins, in accordance with WEEE regulations.
The mechanical durability of this contact block is rated at 5 million cycles, indicating its ability to withstand a significant number of operations over its lifespan.
This content has been produced using multiple sources. EU Automation takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
All parts new or reconditioned are covered by EU Automation 12 month warranty
No hassle returns policy
Dedicated customer support team
We understand that credit is a necessary part of business and offer credit agreements on request, subject to status.
Payment optionsWe accept Bank transfers and the following methods of payment:
All transactions are handled securely by HSBC and HSBC Merchant Services. For more information, please visit our dedicated payments page.
Global supplier of quality automation and control components
Dispose of your old unit by exchanging it for a working part.
A comprehensive repair service for faulty equipment.
You don’t need tights and a cape to be a hero.
Get parts fast and feel like a legend, just like Jeff.