steve
Got hold of Sime for a Carrier card for…
Got hold of Sime for a Carrier card for a chiller. Machine down in a factory. Received the new card in express time machine and plant now up and running fantastic service form Sime
3 months ago
Full 12-month warranty
Available for dispatch immediately
We deliver worldwide
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
All orders are subject to product availability. See our T&Cs.
Ask our team
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
| Specification | Description |
|---|---|
| Part Number | LADN203 |
| Manufacturer | Schneider Electric |
| Product Type | Auxiliary Contact Block |
| Range | TeSys D, TeSys D Control Relay |
| Device Short Name | LADN |
| Range Compatibility | TeSys D CAD, TeSys D LC1D, TeSys Deca CAD, TeSys Deca LC1D |
| Mounting Location | Front |
| Pole Contact Composition | 2 Normally Open (NO) Contacts |
| Contacts Operation | Instantaneous |
| Rated Operational Voltage (Ue) | 690 V AC 25...400 Hz |
| Rated Insulation Voltage (Ui) | 690 V conforming to IEC 60947-5-1, 600 V conforming to UL, 600 V conforming to CSA |
| Conventional Free Air Thermal Current (Ith) | 10 A (at 60 °C) |
| Rated Making Capacity (Irms) | 140 A AC conforming to IEC 60947-5-1, 250 A DC conforming to IEC 60947-5-1 |
| Permissible Short-Time Rating | 100 A at 60 °C for 1 s, 120 A at 60 °C for 500 ms, 140 A at 60 °C for 100 ms |
| Protection Type | GG fuse 10 A |
| Mechanical Durability | 30 Million cycles |
| Minimum Switching Current | 5 mA |
| Minimum Switching Voltage | 17 V |
| Non-Overlap Time | 1.5 ms on de-energisation and energisation, no overlap between NC and NO contact |
| Insulation Resistance | > 10 MOhm |
| Environmental Characteristic | Normal environment |
| IP Degree of Protection | IP20 conforming to IEC 60529 |
| Protective Treatment | TH conforming to IEC 60068 |
| Ambient Air Temperature for Operation | -5…60 °C |
| Ambient Air Temperature for Storage | -60…80 °C |
| Operating Altitude | Up to 3000 m without derating in temperature |
| Sustainable Offer Status | Green Premium product |
| REACh Regulation | Free of Substances of Very High Concern (SVHC) |
| EU RoHS Directive | Compliant |
| China RoHS Regulation | China RoHS Declaration |
| Environmental Disclosure | Product Environmental Profile |
| WEEE | Must be disposed of according to specific waste collection in the European Union |
The auxiliary contact block is used to provide additional switching functions in a control circuit. It can be used for signalling, interlocking, and auxiliary circuits.
This contact block is designed for front mounting, which allows for easy installation directly onto compatible contactors and control relays.
The contact block is equipped with spring terminals, which are suitable for connecting both flexible and solid cables without the need for cable ends.
The rated operational voltage for the LADN203 is 690 V AC at frequencies ranging from 25 to 400 Hz.
The contact block can operate in normal environmental conditions, with an ambient air temperature range for operation of -5 to 60°C and for storage from -60 to 80°C. It is also rated for use at altitudes up to 3000 meters without derating.
The contact block has an IP20 degree of protection, conforming to IEC 60529, which provides protection against solid objects larger than 12mm but not against liquids.
No, it is specifically designed to be compatible with TeSys D contactors and control relays, ensuring proper fit and function.
The conventional free air thermal current rating (Ith) for the contact block is 10 A at 60°C.
The contact block is certified by international standards including UL, CSA, and it conforms to IEC and EN standards.
The mechanical durability of the contact block is rated at 30 million cycles, indicating its ability to withstand a high number of operations.
This content has been produced using multiple sources. EU Automation takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
All parts new or reconditioned are covered by EU Automation 12 month warranty
No hassle returns policy
Dedicated customer support team
We understand that credit is a necessary part of business and offer credit agreements on request, subject to status.
Payment optionsWe accept Bank transfers and the following methods of payment:
All transactions are handled securely by HSBC and HSBC Merchant Services. For more information, please visit our dedicated payments page.
Global supplier of quality automation and control components
Dispose of your old unit by exchanging it for a working part.
A comprehensive repair service for faulty equipment.
You don’t need tights and a cape to be a hero.
Get parts fast and feel like a legend, just like Jeff.