Schneider GV3P80 is a TeSys GV3/TeSys Deca motor circuit breaker designed for three-phase motor protection in industrial control panels. This thermal-magnetic breaker provides adjustable overload protection from 70 to 80 A, with magnetic short-circuit tripping at 1120 A. It is rated for AC networks up to 690 V at 50/60 Hz and is suitable for motor applications up to 45 kW at 400/415 V or 500 V, and up to 55 kW at 690 V.

Built with a rotary handle and EverLink terminals, the GV3P80 supports secure wiring and straightforward panel integration. It can be mounted on a 35 mm DIN rail or fixed directly to a panel using M4 screws. The compact frame measures approximately 55 mm wide, 132 mm high and 136 mm deep, making it suitable for dense control cabinet layouts.

The unit offers high breaking capacity, including 65 kA at 230/240 V and 50 kA at 400/415 V, with suitability for isolation in accordance with IEC 60947-1. It also includes phase failure sensitivity, continuous duty operation and IP20 protection, making it a dependable choice for machinery, motor control centres, pumps, compressors, conveyors and other industrial motor protection applications.
Specification Description
Manufacturer Schneider Electric
Part Number GV3P80
Product Type Motor circuit breaker
Series TeSys GV3 / TeSys Deca frame 3
Device Short Name GV3P
Application Motor protection for AC motor circuits
Trip Unit Technology Thermal-magnetic
Poles 3P
Rated Current 80 A
Thermal Protection Adjustment Range 70 to 80 A
Magnetic Tripping Current 1120 A
Rated Operational Voltage 690 V AC, 50/60 Hz
Rated Insulation Voltage 690 V AC
Rated Impulse Withstand Voltage 6 kV
Utilisation Category AC-3
Breaking Capacity 65 kA at 230/240 V AC; 50 kA at 400/415 V AC; 50 kA at 440 V AC; 12 kA at 500 V AC; 6 kA at 690 V AC
Rated Service Short-Circuit Breaking Capacity 100% at 230/240 V AC; 60% at 400/415 V AC; 60% at 440 V AC; 50% at 500 V AC; 50% at 690 V AC
Motor Power Rating 45 kW at 400/415 V AC; 45 kW at 500 V AC; 55 kW at 690 V AC
Control Type Rotary handle
Connection Type EverLink BTR screw terminals
Terminal Capacity 1 x 1 to 35 mm² or 2 x 1 to 25 mm² conductors, depending on cable type
Tightening Torque 5 N.m for 25 mm² cable; 8 N.m for 35 mm² cable
Mounting Method 35 mm DIN rail clipped or panel mounted with 3 x M4 screws
Phase Failure Sensitivity Yes
Isolation Suitability Yes
Rated Duty Continuous
Power Dissipation 8 W per pole
Mechanical Durability 50,000 cycles
Electrical Durability 20,000 cycles at AC-3, 415 V
Operating Rate Up to 25 cycles per hour
Degree of Protection IP20
Impact Protection IK09
Operating Temperature -20 to 60 °C
Storage Temperature -40 to 80 °C
Operating Altitude Up to 3000 m
Dimensions 55 mm width x 132 mm height x 136 mm depth
Weight 0.96 kg
Colour Dark grey
Standards EN/IEC 60947-2, EN/IEC 60947-4-1, CSA C22.2 No. 60947-4-1
Certifications CCC, CSA, EAC, ATEX, LROS, BV, ABS, DNV-GL, UKCA
Commodity Code 853620

What type of electrical device is this?

It is a 3-pole thermal-magnetic motor circuit breaker from the TeSys GV3/TeSys Deca range, designed for motor protection in AC industrial control panels.

What current range does it cover?

The adjustable thermal protection range is 70 to 80 A, with an 80 A rated current. This makes GV3P80 suitable for motor circuits that fall within that current band.

What is the magnetic tripping current?

The magnetic tripping current is 1120 A, providing short-circuit protection alongside the adjustable thermal overload protection.

How many poles does this circuit breaker have?

It is a 3-pole device, intended for three-phase AC motor protection applications.

What rated operational voltage is it designed for?

The rated operational voltage is 690 V AC at 50/60 Hz, making it suitable for a range of industrial three-phase motor circuits.

What motor power ratings are associated with this device?

Typical motor power ratings are 45 kW at 400/415 V AC, 45 kW at 500 V AC, and 55 kW at 690 V AC, subject to the overall installation design and application requirements.

What breaking capacity does it provide?

The listed Icu breaking capacities include 65 kA at 230/240 V AC, 50 kA at 400/415 V AC, 50 kA at 440 V AC, 12 kA at 500 V AC, and 6 kA at 690 V AC.

How is it mounted in a panel?

It can be clipped onto a 35 mm symmetrical DIN rail or mounted directly to a panel using three M4 screws.

What type of control handle does it use?

It uses a rotary handle for manual operation, allowing the device to be switched and reset from the front of the panel.

What are the main dimensions?

The main body dimensions are approximately 55 mm wide, 132 mm high and 136 mm deep, with a net weight of around 0.96 kg.

What terminal tightening torque is specified?

The specified tightening torque is 5 N.m on the screw clamp terminals.

What level of ingress protection does it have?

The device has an IP20 degree of protection, meaning it is intended for use inside a suitable electrical enclosure.

What standards are associated with this device?

It is associated with EN/IEC 60947-2 and EN/IEC 60947-4-1, with CSA C22.2 No. 60947-4-1 also listed in the product data.

Can it be used for isolation?

Yes, the product data lists it as suitable for isolation in accordance with IEC 60947-1, provided it is installed and applied correctly.

What ambient operating temperature range is specified?

The specified ambient air temperature range for operation is -20 °C to 60 °C.

What is the recommended spacing between neighbouring circuit breakers?

The product data notes that a 9 mm space should be left between two circuit breakers, either as an empty space or by using suitable side-mounted auxiliary contact blocks. Side-by-side mounting is noted as possible up to 40 °C.

  • Motor protection in industrial control panels
  • Overload and short-circuit protection for three-phase AC motors
  • Manual motor starting and isolation in machinery applications
  • Protection of pumps, compressors, fans and conveyors
  • Use in motor control centres for production and process equipment
  • Integration into TeSys GV3 motor starter assemblies
  • Panel-mounted protection for 70–80 A motor circuits
  • DIN rail installation in electrical enclosures
  • Protection for motors operating on 400/415 V, 500 V or 690 V AC networks
  • Machinery installations requiring thermal-magnetic motor circuit protection

This content has been produced using multiple sources. EU Automation takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.

Delivery

  • Logistic partners UPS, FedEx and DHL
  • International delivery available
  • Premium nine hour delivery service available to anywhere in Europe
  • Same day dispatch from group stock

Warranty

All parts new or reconditioned are covered by EU Automation 12 month warranty

Returns

No hassle returns policy

Dedicated customer support team

Trade Credit

We understand that credit is a necessary part of business and offer credit agreements on request, subject to status.

Payment options

We accept Bank transfers and the following methods of payment:

All transactions are handled securely by HSBC and HSBC Merchant Services. For more information, please visit our dedicated payments page.

Services

Sourcing your part

Global supplier of quality automation and control components

Service Exchange

Dispose of your old unit by exchanging it for a working part.

Repair

A comprehensive repair service for faulty equipment.

Customer reviews

5 out of 5 stars steve

Got hold of Sime for a Carrier card for…


Got hold of Sime for a Carrier card for a chiller. Machine down in a factory. Received the new card in express time machine and plant now up and running fantastic service form Sime

3 months ago

5 out of 5 stars Daniel

Excellent customer service...


Alex Bailey is my main point of contact at EU Automation...he is extremely friendly, has exceptional customer service skills and always offers great pricing & lead times.

5 months ago

5 out of 5 stars Jerry Schrink

Tom Higgins provided amazing service


Tom Higgins provided great prompt service. I contacted Tom by phone and within 10 minutes there was a quote in my in box. WOW Thank you Tom and Thank you EU Automation!

5 months ago

5 out of 5 stars Paulo Pereira

Excellent service and communication…


Excellent service and communication from Alex Bailey. He truly goes above and beyond to ensure his clients are 100% satisfied. The entire process was seamless, and his attention to detail made a huge difference. Highly recommended for anyone looking for amazing service!

5 months ago

5 out of 5 stars Gary

Tom Higgins did a great job at getting…


Tom Higgins did a great job at getting us the part we needed. He saw a concern with the part a verified before shipping.

5 months ago

5 out of 5 stars Lessle Smith

Thomas Higgins has gone above and…


Thomas Higgins has gone above and beyond to make things happen for my facility. His customer service and knowledge were an asset in helping me with my order and the logistics challenges!

6 months ago

Factory worker carrying automation parts box.

Be a Factory Hero.

Get parts fast.

You don’t need tights and a cape to be a hero.
Get parts fast and feel like a legend, just like Jeff.

Be a Factory Hero

FAQs

View all FAQs

We're here when you need us