steve
Got hold of Sime for a Carrier card for…
Got hold of Sime for a Carrier card for a chiller. Machine down in a factory. Received the new card in express time machine and plant now up and running fantastic service form Sime
3 months ago
Full 12-month warranty
Available for dispatch immediately
We deliver worldwide
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
All orders are subject to product availability. See our T&Cs.
Ask our team
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
| Specification | Description |
|---|---|
| Manufacturer | Schneider Electric |
| Part number | EZC100H2032 |
| Product range | EasyPact |
| Series | EasyPact EZC100H |
| Product type | Fixed thermal-magnetic circuit breaker |
| Typical application | Designed for power distribution duties in AC and DC installations |
| Pole configuration | 2 poles |
| Protected poles | 2 protected poles |
| Rated current | 32 A at 40 °C |
| Trip unit | TM-D thermal-magnetic trip unit |
| Trip unit rating | 32 A at 50 °C |
| Protection functions | Overload protection and short-circuit protection |
| Network type | Suitable for AC and DC networks |
| Network frequency | 50/60 Hz |
| Rated insulation voltage (Ui) | 690 V AC, 50/60 Hz, conforming to IEC 60947-2 |
| Rated impulse withstand voltage (Uimp) | 6 kV, conforming to IEC 60947-2 |
| Rated operational voltage (Ue) | 550 V AC, 50/60 Hz; 250 V DC |
| Breaking capacity code | H |
| Breaking capacity (Icu) | 100 kA at 110 to 130 V AC; 50 kA at 220 to 240 V AC; 30 kA at 380 to 400 V AC; 30 kA at 415 V AC; 20 kA at 440 V AC; 10 kA at 550 V AC; 10 kA at 125 V DC 1P; 10 kA at 250 V DC 2P |
| Rated service breaking capacity (Ics) | 50 kA at 110 to 130 V AC; 25 kA at 220 to 240 V AC; 15 kA at 380 to 400 V AC; 7.5 kA at 415 V AC; 5 kA at 440 V AC; 2.5 kA at 550 V AC; 5 kA at 125 V DC; 5 kA at 250 V DC |
| Isolation suitability | Suitable for isolation in accordance with IEC 60947-2 |
| Utilization category | Category A |
| Pollution degree | 3 |
| Control type | Toggle operated |
| Mounting mode | Fixed mounting |
| Mounting support | Backplate mounted |
| Connection orientation | Front connection on both line and load sides |
| Connection pitch | 25 mm |
| Local indication | Positive contact indication |
| Neutral protection | Without neutral protection setting |
| Earth-leakage protection | Without earth-leakage protection |
| Mechanical durability | 8,500 operating cycles |
| Electrical durability | 1,500 operating cycles at 415 V AC, 50/60 Hz, Category A, conforming to IEC 60947-2 |
| IP rating | IP20 conforming to IEC 60529 |
| IK rating | IK07 conforming to EN 50102 |
| Operating temperature | -25 to 70 °C |
| Storage temperature | -35 to 85 °C |
| Height | 130 mm |
| Width | 50 mm |
| Depth | 60 mm |
| Package quantity | 1 unit |
| Package dimensions | 9 cm height, 5.5 cm width, 11.35 cm length |
| Package weight | 556 g |
| Standards | GB/T 14048.2, EN/IEC 60947-1, EN/IEC 60947-2, JIS C8201-2-2 |
| Environmental status | Green Premium product |
| REACh status | REACh free of SVHC |
| RoHS status | EU RoHS compliant |
| Material compliance | Free of toxic heavy metals and mercury |
This is a fixed thermal-magnetic molded case circuit breaker for power distribution applications. It is designed for overload and short-circuit protection in AC and DC installations.
This unit is rated at 32 A, has 2 poles, and is designed for 50/60 Hz networks. Its rated insulation voltage is 690 V AC, rated operational voltage is up to 550 V AC and 250 V DC, and rated impulse withstand voltage is 6 kV.
The breaker has a high breaking-capacity code of H. Key Icu values include 30 kA at 415 V AC, 30 kA at 380 to 400 V AC, 50 kA at 220 to 240 V AC, 20 kA at 440 V AC, and 10 kA at 250 V DC.
A thermal-magnetic trip unit combines two protective functions in one device: thermal operation for overload conditions and magnetic operation for short-circuit conditions. On the Schneider EZC100H2032, this gives straightforward protection for distribution circuits without requiring electronic adjustment features.
It is suitable for both AC and DC networks. The published ratings cover AC operation at 50/60 Hz as well as DC operation up to 250 V DC, so it can be considered for a range of distribution panel applications where the electrical characteristics match the installation.
This is a fixed-mount device designed for backplate mounting. Both the line-side and load-side connections are front connected, which can help simplify panel layout and access during installation.
No. This breaker provides overload and short-circuit protection, but it does not include earth-leakage protection.
The overall dimensions are 130 mm high, 50 mm wide, and 60 mm deep. The connection pitch is 25 mm.
This breaker is specified for ambient operating temperatures from -25 °C to 70 °C, with storage temperatures from -35 °C to 85 °C. It has an IP20 degree of protection and an IK07 impact rating.
Yes. It is stated as suitable for isolation in accordance with IEC 60947-2, making it appropriate for applications where that function is required within the broader electrical design.
The device is listed to EN/IEC 60947-1, EN/IEC 60947-2, GB/T 14048.2, and JIS C8201-2-2. These references are commonly used when specifying low-voltage circuit protection equipment for industrial and commercial systems.
Yes. It includes positive contact indication, which gives a clear local indication of the breaker contact position.
The breaker is rated for 8,500 mechanical cycles and 1,500 electrical cycles at 415 V AC 50/60 Hz under Category A conditions in accordance with IEC 60947-2.
It is generally selected for distribution duties in low-voltage electrical panels, including control panels, switchboards, and other installations where a compact 2-pole breaker with fixed thermal-magnetic protection is required.
This content has been produced using multiple sources. EU Automation takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
All parts new or reconditioned are covered by EU Automation 12 month warranty
No hassle returns policy
Dedicated customer support team
We understand that credit is a necessary part of business and offer credit agreements on request, subject to status.
Payment optionsWe accept Bank transfers and the following methods of payment:
All transactions are handled securely by HSBC and HSBC Merchant Services. For more information, please visit our dedicated payments page.
Global supplier of quality automation and control components
Dispose of your old unit by exchanging it for a working part.
A comprehensive repair service for faulty equipment.
You don’t need tights and a cape to be a hero.
Get parts fast and feel like a legend, just like Jeff.