steve
Got hold of Sime for a Carrier card for…
Got hold of Sime for a Carrier card for a chiller. Machine down in a factory. Received the new card in express time machine and plant now up and running fantastic service form Sime
3 months ago
Full 12-month warranty
Available for dispatch immediately
We deliver worldwide
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
All orders are subject to product availability. See our T&Cs.
Ask our team
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
| Specification | Description |
|---|---|
| Part Number | CAD50F7 |
| Manufacturer | Schneider |
| Product Type | Control Relay |
| Device Short Name | CAD |
| Contactor Application | Control Circuit |
| Utilisation Category | DC-13, AC-15, AC-14 |
| Pole Contact Composition | 5 NO |
| Rated Operational Voltage (Ue) | <= 690 V AC 25...400 Hz |
| Control Circuit Type | AC 50/60 Hz |
| Control Circuit Voltage (Uc) | 110 V AC 50/60 Hz |
| Rated Impulse Withstand Voltage | 6 kV IEC 60947 |
| Conventional Free Air Thermal Current (Ith) | 10 A at 140 °F (60 °C) |
| Rated Making Capacity | 140 A AC IEC 60947-5-1, 250 A DC IEC 60947-5-1 |
| Rated Short-Time Withstand Current | 100 A for 1 s, 120 A for 500 ms, 140 A for 100 ms |
| Associated Fuse Rating | 10 A gG IEC 60947-5-1 |
| Rated Insulation Voltage (Ui) | 600 V UL, 600 V CSA, 690 V IEC 60947-5-1 |
| Mounting Support | Rail, Plate |
| Connections - Terminals | Screw clamp terminals for various wire types and sizes |
| Tightening Torque | 10.62 lbf.in (1.2 N.m) with specified screw clamp terminals |
| Control Circuit Voltage Limits | Operational at 0.8...1.1 Uc 50 Hz, Drop-out at 0.3...0.6 Uc |
| Operating Time | 12...22 ms for coil energisation and NO closing, 4...12 ms for coil de-energisation and NO opening |
| Mechanical Durability | 30 Mcycles |
| Maximum Operating Rate | 180 cyc/mn |
| Inrush Power in VA | 70 VA at 50 Hz 68 °F (20 °C) |
| Hold-in Power Consumption in VA | 8 VA at 50 Hz 68 °F (20 °C) |
| Minimum Switching Voltage | 17 V |
| Minimum Switching Current | 5 mA |
| Non-overlap Time | 1.5 ms on energisation and de-energisation between NC and NO contact |
| Insulation Resistance | > 10 MOhm |
| Mechanical Robustness | Shocks: control relay open 10 Gn for 11 ms, control relay closed 15 Gn for 11 ms |
| Vibrations | Control relay open 2 Gn, 5...300 Hz, control relay closed 4 Gn, 5...300 Hz |
| Height | 3.03 in (77 mm) |
| Width | 1.77 in (45 mm) |
| Depth | 3.31 in (84 mm) |
| Net Weight | 1.28 lb(US) (0.58 kg) |
| Standards | BS 4794, EN 60947-5, IEC 60947-5-1, NF C 63-140, VDE 0660, IEC 60335-1 |
| Product Certifications | UL, CSA, UKCA |
| IP Degree of Protection | IP2x front face VDE 0106 |
| Protective Treatment | TH IEC 60068 |
| Ambient Air Temperature for Operation | -40…140 °F (-40…60 °C), 140…158 °F (60…70 °C) with derating |
| Ambient Air Temperature for Storage | -76…176 °F (-60…80 °C) |
| Operating Altitude | 0...9842.52 ft (0...3000 m) |
| Country of Origin | ID |
| Commodity Code | 853649 |
The control relay operates with a control circuit voltage of 110 V AC at 50/60 Hz.
The relay features a pole contact composition of 5 normally open (NO) contacts.
The rated operational voltage of the control relay is less than or equal to 690 V AC at frequencies between 25 and 400 Hz.
The utilisation categories for this relay are DC-13, AC-15, and AC-14.
The rated insulation voltage for this relay is 600 V for UL and CSA standards, and 690 V according to IEC 60947-5-1.
The dimensions of the relay are a height of 3.03 inches (77 mm), a width of 1.77 inches (45 mm), and a depth of 3.31 inches (84 mm).
The mechanical durability of the relay is rated at 30 million cycles.
The inrush power of the relay is 70 VA at 50 Hz and 68°F (20°C), and the hold-in power consumption is 8 VA at 50 Hz and 68°F (20°C).
The minimum switching voltage is 17 V, and the minimum switching current is 5 mA.
The relay can operate in ambient air temperatures ranging from -40 to 140°F (-40 to 60°C), and it can be stored in temperatures ranging from -76 to 176°F (-60 to 80°C). It is also rated for operation at altitudes up to 9842.52 feet (3000 meters).
This content has been produced using multiple sources. EU Automation takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
All parts new or reconditioned are covered by EU Automation 12 month warranty
No hassle returns policy
Dedicated customer support team
We understand that credit is a necessary part of business and offer credit agreements on request, subject to status.
Payment optionsWe accept Bank transfers and the following methods of payment:
All transactions are handled securely by HSBC and HSBC Merchant Services. For more information, please visit our dedicated payments page.
Global supplier of quality automation and control components
Dispose of your old unit by exchanging it for a working part.
A comprehensive repair service for faulty equipment.
You don’t need tights and a cape to be a hero.
Get parts fast and feel like a legend, just like Jeff.