steve
Got hold of Sime for a Carrier card for…
Got hold of Sime for a Carrier card for a chiller. Machine down in a factory. Received the new card in express time machine and plant now up and running fantastic service form Sime
3 months ago
Full 12-month warranty
Available for dispatch immediately
We deliver worldwide
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
All orders are subject to product availability. See our T&Cs.
Ask our team
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
| Specification | Description |
|---|---|
| Manufacturer | Schneider Electric |
| Part Number | C16B4TM160 |
| Product Type | Moulded-case circuit breaker |
| Product Range | ComPacT NSX, new generation |
| Device Series | NSX160B |
| Application | Electrical distribution |
| Rated Current | 160 A at 40 °C |
| Rated Operational Voltage | Up to 690 V AC |
| Network Frequency | 50/60 Hz |
| Number of Poles | 4 |
| Protected Poles | 4D, including fully protected neutral |
| Neutral Position | Left |
| Trip Unit | TM-D thermal-magnetic |
| Protection Functions | Thermal overload and magnetic short-circuit protection |
| Thermal Pick-up Adjustment | Adjustable from 0.7 to 1 × In |
| Instantaneous Pick-up | Fixed at 1,250 A |
| Breaking Capacity at 220/240 V AC | 40 kA |
| Breaking Capacity at 380/415 V AC | 25 kA |
| Breaking Capacity at 440 V AC | 20 kA |
| Breaking Capacity at 500 V AC | 15 kA |
| Performance Level | B, 25 kA at 415 V AC |
| Rated Insulation Voltage | 800 V AC |
| Impulse Withstand Voltage | 8 kV |
| Utilisation Category | Category A |
| Isolation Suitability | Suitable for isolation in accordance with EN/IEC 60947-2 |
| Control Type | Toggle |
| Mounting Method | Fixed, backplate mounting |
| Mounting Orientation | Horizontal or vertical |
| Connection Position | Front, upper and lower |
| Connection Pitch | 35 mm |
| Auxiliary Slots | 5 |
| Earth-Leakage Protection | Not included |
| Mechanical Endurance | 40,000 cycles |
| Power Dissipation | 13.95 W per pole |
| Protection Rating | IP40 |
| Impact Resistance | IK07 |
| Pollution Degree | 3 |
| Operating Temperature | -25 to 70 °C |
| Storage Temperature | -50 to 85 °C |
| Relative Humidity | 0 to 95% |
| Operating Altitude | Up to 2,000 m without derating; 2,000–5,000 m with derating |
| Dimensions | 140 mm W × 161 mm H × 86 mm D |
| Net Weight | 2.6 kg |
| Compliance Standard | EN/IEC 60947-2 |
| Commodity Code | 853620 |
It is a fixed ComPacT NSX160B moulded-case circuit breaker designed for AC electrical distribution. It uses a TM-D thermal-magnetic trip unit to provide overload and short-circuit protection.
The rated current is 160 A at an ambient temperature of 40 °C.
The C16B4TM160 has four poles and a 4D protected-pole configuration, meaning that all four poles, including the neutral, are fully protected.
The rated operational voltage is up to 690 V AC at 50 or 60 Hz.
Its ultimate short-circuit breaking capacity is 25 kA at 380/415 V AC. The corresponding values are 40 kA at 220/240 V AC, 20 kA at 440 V AC and 15 kA at 500 V AC.
The TM-D trip unit provides LI protection: thermal protection against sustained overloads and magnetic protection against short circuits. Integrated earth-leakage protection is not included.
Yes. The long-time thermal pick-up setting can be adjusted from 0.7 to 1 times the rated current, providing an approximate setting range of 112 A to 160 A.
The instantaneous magnetic protection setting is fixed at 1,250 A.
Yes. The neutral is positioned on the left and protected at 1 times the selected thermal setting as part of the four-pole, 4D configuration.
This is a fixed circuit breaker intended for backplate mounting. It can be installed horizontally or vertically, with front connections on both the incoming and outgoing sides.
The unit measures 140 mm wide, 161 mm high and 86 mm deep. Its net weight is approximately 2.6 kg.
The specified operating temperature range is -25 °C to 70 °C, with relative humidity from 0% to 95%. It can operate up to 2,000 metres without derating and from 2,000 to 5,000 metres with derating.
The circuit breaker has an IP40 ingress protection rating and an IK07 mechanical impact rating when assessed under the stated IEC standards.
The device conforms to EN/IEC 60947-2 and is suitable for isolation in accordance with that standard.
The rated insulation voltage is 800 V AC, while the rated impulse withstand voltage is 8 kV.
The circuit breaker provides five slots for compatible electrical auxiliaries.
The specified mechanical endurance is 40,000 operating cycles. Electrical endurance varies according to operating voltage and load conditions.
The stated power dissipation is 13.95 W per pole under the specified operating conditions.
This content has been produced using multiple sources. EU Automation takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
All parts new or reconditioned are covered by EU Automation 12 month warranty
No hassle returns policy
Dedicated customer support team
We understand that credit is a necessary part of business and offer credit agreements on request, subject to status.
Payment optionsWe accept Bank transfers and the following methods of payment:
All transactions are handled securely by HSBC and HSBC Merchant Services. For more information, please visit our dedicated payments page.
Global supplier of quality automation and control components
Dispose of your old unit by exchanging it for a working part.
A comprehensive repair service for faulty equipment.
You don’t need tights and a cape to be a hero.
Get parts fast and feel like a legend, just like Jeff.