steve
Got hold of Sime for a Carrier card for…
Got hold of Sime for a Carrier card for a chiller. Machine down in a factory. Received the new card in express time machine and plant now up and running fantastic service form Sime
3 months ago
Full 12-month warranty
Available for dispatch immediately
We deliver worldwide
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
All orders are subject to product availability. See our T&Cs.
Ask our team
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
| Specification | Description |
|---|---|
| Manufacturer | Schneider Electric |
| Part number | C11F3TM063L |
| Product range | ComPacT NSXm, new generation |
| Device designation | NSXm 63F |
| Product type | Three-pole circuit breaker with a thermal-magnetic trip unit and EverLink terminals, designed for electrical distribution applications. |
| Rated current | 63 A at 40 °C |
| Poles | 3 poles, all three protected |
| Trip unit | TM-D thermal-magnetic |
| Protection functions | Adjustable thermal overload protection and fixed instantaneous short-circuit protection |
| Thermal protection adjustment | 0.7–1 × rated current |
| Thermal protection delay | Fixed |
| Instantaneous trip threshold | 800 A, fixed |
| Earth-leakage protection | Not included |
| Rated operational voltage | 690 V AC |
| Network frequency | 50/60 Hz |
| Rated insulation voltage | 800 V AC |
| Rated impulse withstand voltage | 8 kV |
| Ultimate short-circuit breaking capacity (Icu) | 85 kA at 220–240 V AC; 36 kA at 380–415 V AC; 35 kA at 440 V AC; 15 kA at 500 V AC; 10 kA at 525 V AC |
| Service short-circuit breaking capacity (Ics) | 85 kA at 220–240 V AC; 36 kA at 380–415 V AC; 30 kA at 440 V AC; 10 kA at 500 V AC; 10 kA at 525 V AC |
| Performance level | F: 36 kA at 415 V AC |
| Utilisation category | Category A |
| Isolation suitability | Suitable for isolation in accordance with IEC 60947-2 |
| Operating mechanism | Toggle |
| Mounting | Fixed installation on a backplate |
| Mounting orientation | Horizontal or vertical, flat against the backplate |
| Terminal type | EverLink cable lugs with front-accessible upper and lower connections |
| Rigid or stranded conductor capacity | 2.5–95 mm² aluminium or copper |
| Flexible conductor capacity | 2.5–70 mm² copper |
| Connection pitch | 27 mm without spreaders; 35 mm with spreaders |
| Auxiliary provision | One slot for an OF auxiliary switch, one for an SD alarm switch and one for an MN or MX voltage release |
| Auxiliary indication | Green flag indicates the presence of auxiliary contacts |
| Mechanical endurance | 20,000 operating cycles |
| Electrical endurance | 10,000 cycles at 440 V and rated current; 5,000 cycles at 690 V and rated current |
| Power dissipation | 5.58 W per pole |
| Dimensions | 81 mm wide × 137 mm high × 80 mm deep |
| Net weight | 1.06 kg |
| Colour | Grey, RAL 7016 |
| Ingress protection | IP40 in accordance with IEC 60529 |
| Impact protection | IK07 in accordance with IEC 62262 |
| Pollution degree | Degree 3 in accordance with IEC 60664-1 |
| Operating ambient temperature | −25 °C to +70 °C |
| Storage temperature | −50 °C to +85 °C |
| Relative humidity | 0–95% |
| Operating altitude | Up to 2,000 m without derating; up to 5,000 m with derating |
| Standards | EN/IEC 60947; breaking capacities specified in accordance with IEC 60947-2 |
The C11F3TM063L is a ComPacT NSXm moulded-case circuit breaker designed for electrical distribution. It has three poles, protection on all three poles and a thermal-magnetic TM-D trip unit.
The TM-D trip unit provides thermal protection against sustained overloads and magnetic protection against short circuits. Its long-time protection threshold is adjustable, while the instantaneous magnetic threshold is fixed.
The rated current is 63 A at an ambient temperature of 40 °C. The rated operational voltage is 690 V AC, and the breaker is intended for AC networks operating at 50 or 60 Hz.
At 380–415 V AC, both the rated ultimate short-circuit breaking capacity (Icu) and the rated service short-circuit breaking capacity (Ics) are 36 kA, in accordance with IEC 60947-2. Breaking capacity varies with the operating voltage.
Yes. The long-time thermal protection pick-up can be adjusted from 0.7 to 1 times the rated current. The long-time protection delay is fixed, and the instantaneous magnetic protection pick-up is fixed at 800 A.
No. This configuration provides overload and short-circuit protection but does not include earth-leakage protection.
The EverLink terminals accept rigid or stranded copper and aluminium conductors with cross-sectional areas from 2.5 to 95 mm². Flexible copper conductors are accepted from 2.5 to 70 mm².
The breaker measures 81 mm wide, 137 mm high and 80 mm deep. Its net weight is 1.06 kg, making these useful reference figures when planning panel space and mounting arrangements.
It is a fixed-mounted breaker with backplate mounting support and toggle operation. The specified mounting positions are horizontal, vertical or flat on its back, with front-access connections at both the upper and lower terminals.
The breaker has one slot for an OF auxiliary switch, one slot for an SD alarm switch and one slot for either an MN undervoltage release or an MX shunt release. These provisions allow auxiliary signalling and release functions to be added.
The specified ambient operating temperature range is −25 to 70 °C, and the storage temperature range is −50 to 85 °C. Operation is specified up to 2,000 m without derating and up to 5,000 m with derating. The 63 A current rating is stated at 40 °C.
Yes. The C11F3TM063L is specified as suitable for isolation in accordance with IEC 60947-2 and is classified as a utilisation category A circuit breaker.
The specified ingress protection rating is IP40 in accordance with IEC 60529. Its mechanical impact protection rating is IK07 in accordance with IEC 62262.
This content has been produced using multiple sources. EU Automation takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
All parts new or reconditioned are covered by EU Automation 12 month warranty
No hassle returns policy
Dedicated customer support team
We understand that credit is a necessary part of business and offer credit agreements on request, subject to status.
Payment optionsWe accept Bank transfers and the following methods of payment:
All transactions are handled securely by HSBC and HSBC Merchant Services. For more information, please visit our dedicated payments page.
Global supplier of quality automation and control components
Dispose of your old unit by exchanging it for a working part.
A comprehensive repair service for faulty equipment.
You don’t need tights and a cape to be a hero.
Get parts fast and feel like a legend, just like Jeff.