steve
Got hold of Sime for a Carrier card for…
Got hold of Sime for a Carrier card for a chiller. Machine down in a factory. Received the new card in express time machine and plant now up and running fantastic service form Sime
3 months ago
Full 12-month warranty
Available for dispatch immediately
We deliver worldwide
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
All orders are subject to product availability. See our T&Cs.
Ask our team
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
| Specification | Description |
|---|---|
| Manufacturer | Schneider Electric |
| Part Number | ATS22C32Q |
| Product Range | Altistart 22 |
| Product Type | Soft starter for three-phase asynchronous motors |
| Typical Applications | Pumps and fans |
| Rated Supply Voltage | 230–440 V AC, −15% to +10% |
| Supply Voltage Limits | 195–484 V AC |
| Motor Power | 90 kW at 230 V; 160 kW at 400 V; 160 kW at 440 V |
| Starter Rating | 320 A for standard in-line applications |
| Factory Current Setting | 285 A |
| Number of Phases | 3 |
| Supply Frequency | 50/60 Hz, −10% to +10% |
| Network Frequency | 45–66 Hz |
| Control Circuit Voltage | 230 V AC, −15% to +10%, 50/60 Hz |
| Control Circuit Consumption | 20 W |
| Starting Method | Torque-controlled starting with current limited to 3.5 times the nominal current |
| Utilisation Category | AC-53A |
| Internal Bypass | Integrated |
| Power Dissipation | 150 W in standard applications |
| Device Connection | In-line motor supply connection or connection to the motor delta terminals |
| Digital Inputs | 3 positive-logic inputs: LI1, LI2 and LI3 |
| Digital Input Voltage | 24 V DC, maximum 30 V |
| Relay Outputs | 2 configurable changeover relay outputs: R1 and R2 |
| PTC Probe Input | 750 Ω |
| Communication Protocol | Modbus |
| Communication Interface | RS485 multidrop via one RJ45 connector |
| Transmission Rates | 4,800, 9,600 or 19,200 bps |
| Maximum Connected Devices | 31 |
| Protection Functions | Line phase-failure detection, motor thermal protection and starter thermal protection |
| Cooling Method | Forced convection |
| Mounting Position | Vertical, within ±10° |
| Ingress Protection | IP00 |
| Operating Temperature | −10 to 40 °C without derating; 40 to 60 °C with current derating of 2.2% per °C |
| Storage Temperature | −25 to 70 °C |
| Relative Humidity | 0–95%, non-condensing |
| Operating Altitude | Up to 1,000 m without derating; 1,000–2,000 m with current derating of 2.2% per additional 100 m |
| Pollution Degree | Degree 2 in accordance with IEC 60664-1 |
| Standard | EN/IEC 60947-4-2 |
| Dimensions | 425 mm high × 206 mm wide × 299 mm deep |
| Net Weight | 33 kg |
| Frame Size | D |
| Noise Level | 56 dB |
| Power Terminals | 30 × 5 mm bars with M12 bolts |
| Minimum IEC Power Cable Section | 185 mm² copper, rated at 70 °C |
| Terminal Tightening Torque | 57 N·m |
It is an Altistart 22 soft starter designed to manage the starting and stopping of three-phase asynchronous motors. It progressively controls motor torque to reduce mechanical stress and high starting currents.
The unit is primarily intended for pumps and fans, although it may also be suitable for other compatible asynchronous motor applications following a complete system assessment.
The rated three-phase supply range is 230 to 440 V, with specified supply voltage limits of 195 to 484 V.
The ATS22C32Q is rated for a 90 kW motor at 230 V and a 160 kW motor at either 400 V or 440 V under standard application conditions.
The starter has an IcL rating of 320 A when connected in the motor supply line for standard applications. Its factory current setting is 285 A.
It uses torque-controlled starting, with starting current limited to approximately 3.5 times the configured nominal current. This provides smoother acceleration than direct-on-line starting.
Yes. An internal bypass is incorporated to reduce power losses and heat generation once the motor has reached normal running conditions.
The control circuit requires a nominal 230 V AC supply at 50 or 60 Hz, with an operating tolerance of -15% to +10%.
The unit includes Modbus serial communication through an RJ45 connector. It uses an RS485 multidrop interface and supports transmission rates of 4,800, 9,600 or 19,200 bps.
Three 24 V DC positive-logic digital inputs are provided, identified as LI1, LI2 and LI3. The unit also has two configurable changeover relay outputs, R1 and R2.
Integrated functions include motor thermal protection, starter thermal protection and monitoring for line phase failure. A 750-ohm PTC probe input is also available for motor temperature monitoring.
The unit measures 425 mm high, 206 mm wide and 299 mm deep. Its stated net weight is 33 kg.
It should be installed vertically within 10 degrees of the upright position. Adequate space and enclosure ventilation are required to maintain bottom-to-top airflow and dissipate generated heat.
Yes. Its IP00 rating means it is an open device and must be installed within a suitable enclosure selected for the operating environment and required ingress protection.
The starter uses forced-convection cooling and includes a heat sink. The surrounding enclosure must allow sufficient airflow to prevent excessive operating temperatures.
It can operate from -10°C to 40°C without current derating. Operation from above 40°C up to 60°C requires current derating of 2.2% for each additional degree Celsius.
The unit can operate at altitudes up to 1,000 metres without derating. Between 1,000 and 2,000 metres, the current must be derated by 2.2% for every additional 100 metres.
Yes. It may be connected either in the motor supply line or in series with each winding of a compatible delta-connected motor. Inside-delta selection and wiring require careful current calculations and correct motor terminal access.
The power terminals use 30 mm by 5 mm bars with M12 bolts. The specified terminal tightening torque is 57 Nm, and conductor sizing must be confirmed against the installation method, applicable regulations and motor current.
The ATS22C32Q is classified under utilisation category AC-53A for semiconductor motor controllers and starters.
This content has been produced using multiple sources. EU Automation takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
All parts new or reconditioned are covered by EU Automation 12 month warranty
No hassle returns policy
Dedicated customer support team
We understand that credit is a necessary part of business and offer credit agreements on request, subject to status.
Payment optionsWe accept Bank transfers and the following methods of payment:
All transactions are handled securely by HSBC and HSBC Merchant Services. For more information, please visit our dedicated payments page.
Global supplier of quality automation and control components
Dispose of your old unit by exchanging it for a working part.
A comprehensive repair service for faulty equipment.
You don’t need tights and a cape to be a hero.
Get parts fast and feel like a legend, just like Jeff.