steve
Got hold of Sime for a Carrier card for…
Got hold of Sime for a Carrier card for a chiller. Machine down in a factory. Received the new card in express time machine and plant now up and running fantastic service form Sime
1 month ago
Full 12-month warranty
Available for dispatch immediately
We deliver worldwide
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
All orders are subject to product availability. See our T&Cs.
Ask our team
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
| Specification | Description |
|---|---|
| Part Number | ASI20MT4I4OS |
| Manufacturer | Schneider |
| Product Type | Modular Interface |
| Interface Profile | AS-i S7.0.F.E |
| AS-Interface Compatibility | V2.1 |
| Number of Addresses | 0 to 31 |
| Discrete Input Number | 4 |
| Discrete Output Number | 4 transistor outputs at 0.5 A each |
| Rated Supply Voltage | 26.5 to 31.6 V DC on AS-Interface line |
| Maximum Sensor Supply Current | 200 mA |
| Current Consumption | ≤ 50 mA with inputs/outputs on and sensor not energised; 15 mA no load on AS-Interface line |
| Input Compatibility | 2 or 3-wire PNP conforming to IEC 61131-2 Type 2 |
| Discrete Output Voltage | 19.2 to 30 V DC conforming to IEC 60947-5-1 |
| Thermal Current per Channel | 0.5 A (actuator side) |
| Thermal Current per Common | 2 A (actuator side) |
| Rated Operational Current | 0.5 A at 6 cyc/mn for both DC-12 and DC-13 conforming to IEC 60947-5-1 (actuator side) |
| Minimum Output Current | 0.5 mA |
| Leakage Current | ≤ 0.5 mA at 30 V (actuator side) |
| Overcurrent Protection | Built-in electronic (actuator side) |
| Switching Time | 1 ms for ON to OFF and OFF to ON (actuator side) |
| Output Fallback Position | State 0 if watchdog tripped |
| Overvoltage Category | II conforming to EN/IEC 60664-1 |
| Electrical Connection | Removable terminal blocks for sensor side, AS-Interface line, and actuator side |
| Fixing Mode | Clip-on on 35 mm symmetrical DIN rail or by 2 screws Ø 3 mm on panel |
| Housing Material | Polycarbonate |
| Flame Retardance | V0 conforming to UL 94 |
| Ambient Air Temperature for Operation | -20 to 60 °C |
| Ambient Air Temperature for Storage | -40 to 85 °C |
| IP Degree of Protection | IP20 conforming to EN/IEC 60529 |
| Shock Resistance | 15 gn for 11 ms conforming to EN/IEC 60068-2-27 |
| Vibration Resistance | 1 gn (f = 13.2 to 100 Hz); +/-1 mm (f = 2 to 13.2 Hz) |
| Resistance to Electrostatic Discharge | 6 kV conforming to EN/IEC 61000-4-2 |
| Resistance to Radiated Fields | 10 V/m conforming to EN/IEC 61000-4-3 |
| Resistance to Fast Transients | 2 kV conforming to EN/IEC 61000-4-4 |
| Dielectric Test Voltage | 0.5 kV between AS-Interface line and transistor outputs conforming to EN/IEC 60364-4-41 |
| Pollution Degree | 2 conforming to EN/IEC 60664-1 |
| Product Weight | 0.09 kg |
The Schneider Modular Interface utilises an AS-Interface (AS-i) communication protocol, which is a simple and cost-effective wiring system designed to connect binary sensors and actuators to a controller.
Yes, the Schneider Modular Interface is designed to operate within a wide range of ambient temperatures, from -20°C to 60°C for operation, and -40°C to 85°C for storage.
The module has an IP20 degree of protection, conforming to EN/IEC 60529 standards, which means it is protected against solid objects larger than 12.5mm but not against water.
The rated supply voltage for the ASI20MT4I4OS is between 26.5 to 31.6 V DC, which is supplied via the AS-Interface line.
The module features 4 discrete inputs and 4 discrete outputs, each output with a 0.5 A transistor.
The module is compatible with 2 or 3-wire PNP sensors conforming to IEC 61131-2 Type 2 standards.
Yes, it includes built-in electronic overcurrent protection for the actuator side to safeguard against excessive current.
The module is equipped with local signalling through 8 yellow LEDs indicating input/output status, 1 red LED for data exchange or fault indication, and 2 green LEDs for power and auxiliary supply status.
The module can be mounted by clipping onto a 35 mm symmetrical DIN rail or by using two screws on a panel.
The weight of the module is approximately 0.09 kg, making it lightweight and easy to handle during installation.
This content has been produced using multiple sources. EU Automation takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
All parts new or reconditioned are covered by EU Automation 12 month warranty
No hassle returns policy
Dedicated customer support team
We understand that credit is a necessary part of business and offer credit agreements on request, subject to status.
Payment optionsWe accept Bank transfers and the following methods of payment:
All transactions are handled securely by HSBC and HSBC Merchant Services. For more information, please visit our dedicated payments page.
Global supplier of quality automation and control components
Dispose of your old unit by exchanging it for a working part.
A comprehensive repair service for faulty equipment.
You don’t need tights and a cape to be a hero.
Get parts fast and feel like a legend, just like Jeff.