steve
Got hold of Sime for a Carrier card for…
Got hold of Sime for a Carrier card for a chiller. Machine down in a factory. Received the new card in express time machine and plant now up and running fantastic service form Sime
3 months ago
Full 12-month warranty
Available for dispatch immediately
We deliver worldwide
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
All orders are subject to product availability. See our T&Cs.
Ask our team
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
| Specification | Description |
|---|---|
| Manufacturer | Schneider Electric |
| Part Number | A9R12440 |
| Product Range | Acti9 |
| Series / Product Name | Acti9 iID |
| Device Type | Residual Current Circuit Breaker (RCCB) for earth-leakage protection in AC distribution systems |
| Poles | 4P (4 Pole) |
| Neutral Position | Left |
| Rated Current (In) | 40 A |
| Rated Operational Voltage (Ue) | 380 to 415 V AC |
| Mains Frequency | 50/60 Hz |
| Network Type | AC |
| Residual Current Sensitivity | 100 mA |
| Residual Current Protection Class | Type AC |
| Time Delay | Instantaneous |
| Tripping Technology | Voltage independent |
| Rated Making & Breaking Capacity (Im / Idm) | 1500 A / 1500 A |
| Rated Conditional Short-Circuit Current | 10 kA |
| Rated Insulation Voltage (Ui) | 500 V AC |
| Impulse Withstand Voltage (Uimp) | 6 kV |
| Control Type | Toggle |
| Contact Position Indicator | Yes |
| Mounting Mode | Clip-on |
| Mounting Support | DIN rail |
| Module Width | 8 x 9 mm pitches |
| Dimensions (H x W x D) | 91 mm x 72 mm x 73.5 mm |
| Net Weight | 0.37 kg |
| Color | White |
| Terminal Type | Single terminal, top or bottom |
| Conductor Capacity (Rigid) | 1 to 35 mm² |
| Conductor Capacity (Flexible) | 1 to 25 mm² |
| Conductor Capacity (Flexible with Ferrule) | 1 to 25 mm² |
| Wire Stripping Length | 14 mm |
| Tightening Torque | 3.5 N·m |
| Locking Provision | Padlocking device compatible |
| Degree of Protection | IP20 (device), IP40 (in modular enclosure) |
| Operating Ambient Temperature | -5 to +60 °C |
| Storage Ambient Temperature | -40 to +85 °C |
| Pollution Degree | 3 |
| EMC Impulse Withstand | 8/20 µs impulse withstand, 250 A |
| Standards | EN/IEC 61008-1 |
| Product Certification | EAC |
| Country of Origin | ES (Spain) |
| Commodity Code | 853620 |
This is a residual current circuit breaker (RCCB) designed to disconnect the circuit when earth-leakage current is detected, helping to reduce the risk of electric shock and to limit leakage-related hazards in AC distribution systems.
The rated current is 40 A, meaning it is intended to carry up to 40 A continuously under specified conditions.
It is a 4-pole device (4P), typically used for three-phase plus neutral applications, allowing simultaneous disconnection of all conductors protected by the RCCB.
The rated operational voltage is 380 to 415 V AC at 50/60 Hz, suitable for common three-phase low-voltage distribution in that range.
It has a 100 mA residual current sensitivity, meaning it trips when the detected leakage current reaches approximately 100 mA (per applicable standard conditions).
It provides instantaneous earth-leakage protection time delay (no intentional time delay).
Type AC indicates it is designed to operate with residual currents that are sinusoidal AC. It is typically selected for standard AC loads where pulsating DC leakage is not expected.
No. It uses voltage-independent residual current tripping technology, so the residual current detection/tripping function does not rely on the presence of line voltage.
The neutral position is on the left, which can be important for consistent wiring practices and panel layout.
It is a clip-on device designed for DIN rail mounting and occupies 8 modules (8 x 9 mm pitches).
Approximate dimensions are 91 mm (height) x 72 mm (width) x 73.5 mm (depth), with a net weight of about 0.37 kg.
It supports single-terminal connections (top or bottom): rigid conductors 1 to 35 mm², flexible conductors 1 to 25 mm², and flexible conductors with ferrule 1 to 25 mm².
The recommended wire stripping length is 14 mm, and the terminal tightening torque is 3.5 N·m for top or bottom connections.
The device is rated IP20 (per IEC 60529), and it achieves IP40 when installed within a suitable modular enclosure.
It is designed in accordance with EN/IEC 61008-1 for RCCBs.
Operating ambient temperature range is -5 to +60 °C, and storage temperature range is -40 to +85 °C.
The rated conditional short-circuit current is 10 kA, which is used when coordinating the RCCB with appropriate upstream protective devices.
Yes. It supports a padlocking device as a locking option, depending on the installation’s lockout requirements and accessory approach.
The rated insulation voltage is 500 V AC, and the rated impulse withstand voltage is 6 kV.
Yes. It includes a contact position indicator to show the open/closed status of the contacts.
This content has been produced using multiple sources. EU Automation takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
All parts new or reconditioned are covered by EU Automation 12 month warranty
No hassle returns policy
Dedicated customer support team
We understand that credit is a necessary part of business and offer credit agreements on request, subject to status.
Payment optionsWe accept Bank transfers and the following methods of payment:
All transactions are handled securely by HSBC and HSBC Merchant Services. For more information, please visit our dedicated payments page.
Global supplier of quality automation and control components
Dispose of your old unit by exchanging it for a working part.
A comprehensive repair service for faulty equipment.
You don’t need tights and a cape to be a hero.
Get parts fast and feel like a legend, just like Jeff.