steve
Got hold of Sime for a Carrier card for…
Got hold of Sime for a Carrier card for a chiller. Machine down in a factory. Received the new card in express time machine and plant now up and running fantastic service form Sime
3 months ago
Full 12-month warranty
Available for dispatch immediately
We deliver worldwide
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
All orders are subject to product availability. See our T&Cs.
Ask our team
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
| Specification | Description |
|---|---|
| Manufacturer | Schneider Electric |
| Manufacturer Part Number | A9N61525 |
| Product Range | Acti9 |
| Product Name / Series | Acti9 C60H-DC |
| Product Type | Miniature Circuit Breaker (MCB) |
| Part Description | 2‑pole DC miniature circuit breaker designed for compact DIN‑rail installations, providing thermal‑magnetic protection with C‑curve tripping for dependable DC distribution circuits. |
| Poles | 2P |
| Number of Protected Poles | 2 |
| Rated Current (In) | 5 A (at 25 °C) |
| Trip Unit Technology | Thermal-magnetic |
| Tripping Curve | C curve |
| Network Type | DC |
| Rated Operational Voltage (Ue) | 500 V DC |
| Rated Insulation Voltage (Ui) | 500 V DC |
| Rated Impulse Withstand Voltage (Uimp) | 6 kV |
| Utilisation Category | Category A |
| Suitability for Isolation | Yes |
| Breaking Capacity (Icu) | 20 kA at 250 V DC; 20 kA at 220 V DC; 10 kA at 440 V DC; 6 kA at 500 V DC (IEC/EN 60947-2, as applicable) |
| Rated Service Breaking Capacity (Ics) | 15 kA (75% of Icu) at 220 V DC; 15 kA (75% of Icu) at 250 V DC; 7.5 kA (75% of Icu) at 440 V DC; 4.5 kA (75% of Icu) at 500 V DC |
| Contact Position Indicator | Yes |
| Control Type | Toggle |
| Local Signalling | ON/OFF indication |
| Mounting Mode | Fixed |
| Mounting Support | 35 mm symmetrical DIN rail |
| Comb Busbar / Distribution Block Compatibility | Standard, top or bottom |
| Module Pitch | 4 × 9 mm |
| Colour | White |
| Net Weight | 0.256 kg |
| Mechanical Durability | 20,000 cycles |
| Electrical Durability | 3,000 cycles (L/R = 2 ms) |
| Locking Provision | Padlockable |
| Locking Options | Lockable in position O (OFF) |
| Tightening Torque | 2.5 N·m (top or bottom, power circuit) |
| Earth-leakage Protection | Without |
| Standards | EN 60947-2; IEC 60947-2 |
| Pollution Degree | 3 |
| Overvoltage Category | IV |
| Tropicalisation | 2 (IEC 60068-2) |
| Operating Altitude | Up to 2000 m |
| Ambient Temperature (Operation) | -25 to 70 °C |
| Ambient Temperature (Storage) | -40 to 85 °C |
| Network Frequency | 50/60 Hz |
It is a two-pole miniature circuit-breaker (MCB) designed for DC distribution circuits, using a thermal-magnetic trip mechanism to protect against overloads and short-circuits.
Two-pole means it switches and protects two conductors together, providing simultaneous disconnection across both poles for DC circuits.
The rated current is 5 A at 25 °C.
The rated operational voltage is 500 V DC.
A C-curve MCB is intended for circuits with moderate inrush currents, where brief start-up surges may occur without representing a fault, while still providing rapid protection during short-circuits.
The ultimate breaking capacity (Icu) includes 20 kA at 250 V DC, 20 kA at 220 V DC, 10 kA at 440 V DC, and 6 kA at 500 V DC (per IEC/EN 60947-2, with additional GB 14048.2 ratings stated for 220/250 V DC).
The rated service breaking capacity (Ics) is stated as 75% of Icu: 15 kA at 220 V DC, 15 kA at 250 V DC, 7.5 kA at 440 V DC, and 4.5 kA at 500 V DC (IEC/EN 60947-2).
Yes. It is stated as suitable for isolation in accordance with IEC 60947-2 and EN 60947-2.
It is designed for fixed mounting on a 35 mm symmetrical DIN rail.
Yes. It is compatible with standard comb busbars and distribution blocks, top or bottom, with 9 mm pitch (4 modules).
No. This device is specified as “without” earth-leakage protection; it provides overcurrent and short-circuit protection only.
The specified tightening torque for the power circuit terminals is 2.5 N·m (top or bottom).
Yes. It is padlockable, with locking described in position O (OFF).
Ambient air temperature for operation is -25 to +70 °C, and ambient air temperature for storage is -40 to +85 °C.
It is specified to EN 60947-2 and IEC 60947-2.
Mechanical durability is specified as 20,000 cycles. Electrical durability is specified as 3,000 cycles (L/R = 2 ms) in the product data. This device is commonly referenced as Schneider A9N61525.
It is specified for pollution degree 3 and overvoltage category IV.
Net weight is approximately 0.256 kg, and the unit is white.
This content has been produced using multiple sources. EU Automation takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
All parts new or reconditioned are covered by EU Automation 12 month warranty
No hassle returns policy
Dedicated customer support team
We understand that credit is a necessary part of business and offer credit agreements on request, subject to status.
Payment optionsWe accept Bank transfers and the following methods of payment:
All transactions are handled securely by HSBC and HSBC Merchant Services. For more information, please visit our dedicated payments page.
Global supplier of quality automation and control components
Dispose of your old unit by exchanging it for a working part.
A comprehensive repair service for faulty equipment.
You don’t need tights and a cape to be a hero.
Get parts fast and feel like a legend, just like Jeff.