steve
Got hold of Sime for a Carrier card for…
Got hold of Sime for a Carrier card for a chiller. Machine down in a factory. Received the new card in express time machine and plant now up and running fantastic service form Sime
3 months ago
Full 12-month warranty
Available for dispatch immediately
We deliver worldwide
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
All orders are subject to product availability. See our T&Cs.
Ask our team
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
| Specification | Description |
|---|---|
| Part Number | A9N18372 |
| Manufacturer | Schneider |
| Product Type | Miniature Circuit Breaker (MCB) |
| Range | Acti9 C120 |
| Poles Description | 4P |
| Rated Current | 80 A at 30 °C |
| Network Type | AC |
| Trip Unit Technology | Thermal-magnetic |
| Curve Code | C |
| Breaking Capacity | 10000 A Icn at 230 to 400 V AC 50/60 Hz conforming to EN/IEC 60898-1; 16 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2; 20 kA Icu at 220 to 240 V AC 50/60 Hz conforming to EN/IEC 60947-2 |
| Suitability for Isolation | Yes, conforming to IEC 60947-2 |
| Network Frequency | 50/60 Hz |
| Rated Operational Voltage | 230 to 400 V AC 50/60 Hz; 220 to 240 V AC 50/60 Hz; 380 to 415 V AC 50/60 Hz; 440 V AC 50/60 Hz; <= 500 V DC |
| Magnetic Tripping Limit | 5 to 10 x In |
| Rated Service Breaking Capacity | 7500 A 75% conforming to EN/IEC 60898-1 - 230 to 400 V AC 50/60 Hz; 4.5 kA 75% conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz; 7.5 kA 75% conforming to EN/IEC 60947-2 - 380 to 415 V AC 50/60 Hz |
| Limitation Class | 3 conforming to EN/IEC 60947-2 |
| Rated Insulation Voltage | 500 V AC 50/60 Hz conforming to EN/IEC 60947-2 |
| Rated Impulse Withstand Voltage | 6 kV conforming to EN/IEC 60947-2 |
| Contact Position Indicator | Yes |
| Control Type | Toggle |
| Local Signalling | ON/OFF indication |
| Mounting Mode | Clip-on |
| Mounting Support | 35 mm symmetrical DIN rail |
| Comb Busbar and Distribution Block Compatibility | Yes |
| Height | 81 mm |
| Width | 108 mm |
| Depth | 73 mm |
| Product Weight | 0.82 kg |
| Colour | White |
| Mechanical Durability | 20000 cycles |
| Electrical Durability | 5000 cycles conforming to IEC 60947-2 |
| Locking Options Description | Handle sealable with cable diameter 0.7mm in OFF or ON position |
| Connections - Terminals | Tunnel type terminals 1…50 mm² rigid; Tunnel type terminals 1.5…35 mm² flexible |
| Wire Stripping Length | 15 mm |
| Tightening Torque | 3.5 N.m |
| Earth-leakage Protection | Separate block |
| Standards | EN/IEC 60898-1, EN/IEC 60947-2 |
| Product Certifications | EAC |
| IP Degree of Protection | IP20 conforming to IEC 60529 |
| Pollution Degree | 3 conforming to IEC 60947-2 |
| Overvoltage Category | IV |
| Tropicalisation | 2 conforming to IEC 60068-1 |
| Relative Humidity | 95% at 55 °C |
| Operating Altitude | 2000 m |
| Ambient Air Temperature for Operation | -25 to 70 °C |
| Ambient Air Temperature for Storage | -40 to 85 °C |
| Sustainable Offer Status | Green Premium product |
| REACh Regulation | REACh Declaration, REACh free of SVHC |
| EU RoHS Directive | Compliant, EU RoHS Declaration, Toxic heavy metal free, Mercury free |
| China RoHS Regulation | China RoHS Declaration, RoHS exemption information |
The Schneider A9N18372 is primarily used for distribution applications, providing protection for electrical circuits against overloads and short circuits.
The rated current for the Schneider A9N18372 is 80 A at 30°C.
The Schneider A9N18372 uses thermal-magnetic tripping technology.
The Schneider A9N18372 has a breaking capacity of 10,000 A at 230 to 400 V AC, conforming to EN/IEC 60898-1.
Yes, the Schneider A9N18372 is suitable for isolation, conforming to IEC 60947-2.
The dimensions of the Schneider A9N18372 are 108 mm in width, 73 mm in depth, and 81 mm in height.
The Schneider A9N18372 has an IP20 degree of protection, conforming to IEC 60529.
The Schneider A9N18372 has a mechanical durability of 20,000 cycles.
The Schneider A9N18372 complies with EN/IEC 60898-1 and EN/IEC 60947-2 standards.
The rated operational voltage for the Schneider A9N18372 is 230 to 400 V AC.
This content has been produced using multiple sources. EU Automation takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
All parts new or reconditioned are covered by EU Automation 12 month warranty
No hassle returns policy
Dedicated customer support team
We understand that credit is a necessary part of business and offer credit agreements on request, subject to status.
Payment optionsWe accept Bank transfers and the following methods of payment:
All transactions are handled securely by HSBC and HSBC Merchant Services. For more information, please visit our dedicated payments page.
Global supplier of quality automation and control components
Dispose of your old unit by exchanging it for a working part.
A comprehensive repair service for faulty equipment.
You don’t need tights and a cape to be a hero.
Get parts fast and feel like a legend, just like Jeff.