steve
Got hold of Sime for a Carrier card for…
Got hold of Sime for a Carrier card for a chiller. Machine down in a factory. Received the new card in express time machine and plant now up and running fantastic service form Sime
3 months ago
Full 12-month warranty
Available for dispatch immediately
We deliver worldwide
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
All orders are subject to product availability. See our T&Cs.
Ask our team
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
| Specification | Description |
|---|---|
| Manufacturer | Schneider Electric |
| Part Number | A9F93463 |
| Range | Acti9 |
| Product Name | Acti9 iC60 |
| Device Type | Miniature circuit breaker |
| Device Short Name | iC60L |
| Application | Electrical distribution protection |
| Poles | 4P |
| Protected Poles | 4 |
| Rated Current | 63 A |
| Trip Curve | B curve |
| Trip Unit Technology | Thermal-magnetic |
| Network Type | AC and DC |
| Network Frequency | 50/60 Hz |
| Magnetic Tripping Limit | 4 x In +/- 20% |
| Breaking Capacity | 10 kA Icu at 440 V AC; 15 kA Icu at 380–415 V AC; 30 kA Icu at 220–240 V AC; 70 kA Icu at 12–60 V AC and 100–133 V AC; 20 kA Icu at up to 250 V DC |
| Rated Service Breaking Capacity | 5 kA at 440 V AC; 7.5 kA at 380–415 V AC; 15 kA at 220–240 V AC; 35 kA at 12–133 V AC; 20 kA at 180–250 V DC |
| Utilisation Category | Category A |
| Isolation Suitability | Suitable for isolation |
| Standards | IEC 60947-2 and EN 60947-2 |
| Rated Insulation Voltage | 500 V AC |
| Rated Impulse Withstand Voltage | 6 kV |
| Control Type | Toggle |
| Indication | Contact position indicator and trip indicator |
| Mounting Method | Fixed installation on DIN rail |
| Comb Busbar Compatibility | Compatible at top or bottom |
| 9 mm Pitches | 8 |
| Terminal Type | Single terminal at top or bottom |
| Rigid Cable Capacity | 1 to 35 mm² |
| Flexible Cable Capacity | 1 to 25 mm² |
| Wire Stripping Length | 14 mm |
| Tightening Torque | 3.5 N.m |
| Earth-Leakage Protection | Separate block |
| IP Rating | IP20 |
| Pollution Degree | 3 |
| Overvoltage Category | IV |
| Tropicalisation | 2 |
| Relative Humidity | 95% at 55 °C |
| Operating Altitude | 0 to 2000 m |
| Operating Temperature | -35 to 70 °C |
| Storage Temperature | -40 to 85 °C |
| Height | 85 mm |
| Width | 72 mm |
| Depth | 78.5 mm |
| Net Weight | 0.5 kg |
| Colour | White |
| Mechanical Durability | 20,000 cycles |
| Electrical Durability | 10,000 cycles |
| Sustainability Status | Green Premium product |
| RoHS Status | EU RoHS compliant with exemptions |
| WEEE Information | Requires specific waste collection within European Union markets |
It is a miniature circuit-breaker from the Acti9 iC60 range, designed for distribution applications. The A9F93463 is a 4-pole thermal-magnetic breaker with a 63 A rated current and B curve tripping characteristics.
A B curve breaker is intended to trip at a relatively low magnetic threshold compared with C or D curve devices. For this unit, the magnetic tripping limit is 4 x In ±20%, making it suitable for circuits where high inrush current is not expected.
This device has 4 poles, and all 4 poles are protected. It is intended for multi-pole AC or DC circuit protection arrangements where the electrical design calls for a 4P breaker.
The rated current is 63 A. This means the breaker is designed for circuits where a 63 ampere rating is appropriate, subject to the wider panel design and installation requirements.
The device conforms to IEC 60947-2 and EN 60947-2. It is also suitable for isolation according to these standards.
The breaking capacity depends on voltage and supply type. It is rated at 15 kA Icu at 380...415 V AC, 10 kA Icu at 440 V AC, 30 kA Icu at 220...240 V AC, and 20 kA Icu at up to 250 V DC.
Yes. The device is specified for both AC and DC network types. For AC use, it is rated for 50/60 Hz networks.
It is designed for fixed mounting on a DIN rail. Its modular width is 8 x 9 mm pitches, with overall dimensions of 85 mm height, 72 mm width and 78.5 mm depth.
The terminals accept 1...35 mm² rigid conductors or 1...25 mm² flexible conductors. The specified wire stripping length is 14 mm, with a tightening torque of 3.5 N.m.
Yes. The unit has a toggle control, a trip indicator for local signalling, and a contact position indicator.
It has an IP20 degree of protection and is rated for operation from -35°C to 70°C. Storage temperature is specified from -40°C to 85°C, with relative humidity up to 95% at 55°C.
Yes. The device is compatible with comb busbars and distribution blocks at the top or bottom, helping it integrate into modular distribution assemblies.
This content has been produced using multiple sources. EU Automation takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
All parts new or reconditioned are covered by EU Automation 12 month warranty
No hassle returns policy
Dedicated customer support team
We understand that credit is a necessary part of business and offer credit agreements on request, subject to status.
Payment optionsWe accept Bank transfers and the following methods of payment:
All transactions are handled securely by HSBC and HSBC Merchant Services. For more information, please visit our dedicated payments page.
Global supplier of quality automation and control components
Dispose of your old unit by exchanging it for a working part.
A comprehensive repair service for faulty equipment.
You don’t need tights and a cape to be a hero.
Get parts fast and feel like a legend, just like Jeff.