steve
Got hold of Sime for a Carrier card for…
Got hold of Sime for a Carrier card for a chiller. Machine down in a factory. Received the new card in express time machine and plant now up and running fantastic service form Sime
3 months ago
Full 12-month warranty
Available for dispatch immediately
We deliver worldwide
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
All orders are subject to product availability. See our T&Cs.
Ask our team
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
| Specification | Description |
|---|---|
| Manufacturer | Schneider Electric |
| Part Number | A9F85340 |
| Product Range | Acti9 |
| Product Name | Acti9 iC60H |
| Product Type | Miniature circuit breaker (MCB) for distribution circuits |
| Poles | 3P (3 protected poles) |
| Rated Current (In) | 40 A |
| Tripping Curve | D curve |
| Trip Unit Technology | Thermal-magnetic |
| Network Type | AC / DC |
| Rated Operational Voltage | Up to 440 V AC |
| Network Frequency | 50/60 Hz |
| Magnetic Tripping Limit | 12 × In ±20% |
| Breaking Capacity (Icn) | 10,000 A at 400 V AC (EN/IEC 60898-1) |
| Ultimate Breaking Capacity (Icu) | 10 kA at 440 V AC; 15 kA at 380…415 V AC; 30 kA at 220…240 V AC; 42 kA at 100…133 V AC; 42 kA at 12…60 V AC (EN/IEC 60947-2) |
| DC Breaking Capacity (Icu) | 15 kA at ≤180 V DC (EN/IEC 60947-2) |
| Rated Service Breaking Capacity (Ics) | 5 kA at 440 V AC; 7.5 kA at 380…415 V AC; 15 kA at 220…240 V AC (IEC/EN 60947-2) |
| Current Limitation Class | Class 3 (EN/IEC 60898-1) |
| Utilisation Category | Category A (EN/IEC 60947-2 / IEC 60947-2) |
| Suitability for Isolation | Yes (EN/IEC 60898-1 and EN/IEC 60947-2) |
| Rated Insulation Voltage (Ui) | 500 V AC (EN/IEC 60947-2) |
| Rated Impulse Withstand (Uimp) | 6 kV (EN/IEC 60947-2) |
| Control Type | Toggle |
| Status Indication | Contact position indicator; trip indicator |
| Mounting Mode | Fixed |
| Mounting Support | DIN rail |
| Comb Busbar Compatibility | Top or bottom |
| Width (9 mm Modules) | 6 |
| Dimensions (H × W × D) | 85 × 54 × 78.5 mm |
| Net Weight | 0.375 kg |
| Colour | White |
| Mechanical Durability | 20,000 cycles |
| Electrical Durability | 10,000 cycles |
| Terminal Type | Single terminal (top or bottom) |
| Conductor Size (Rigid) | 1…35 mm² |
| Conductor Size (Flexible) | 1…25 mm² |
| Strip Length | 14 mm |
| Tightening Torque | 3.5 N·m |
| Earth-Leakage Protection | Separate block (when required) |
| IP Rating | IP20 (IEC/EN 60529) |
| Pollution Degree | 3 (IEC/EN 60947-2) |
| Overvoltage Category | IV |
| Operating Temperature | -35…70 °C |
| Storage Temperature | -40…85 °C |
| Operating Altitude | 0…2000 m |
| Relative Humidity | 95% at 55 °C |
| Standards | EN 60898-1, EN 60947-2, IEC 60898-1, IEC 60947-2 |
| Part Description | Schneider Electric Acti9 iC60H miniature circuit breaker, 3-pole 40 A D-curve device with thermal-magnetic protection, designed for DIN-rail installation in distribution boards and suitable for AC or DC applications. |
It is a miniature circuit breaker (MCB) designed for distribution circuits, using a thermal-magnetic trip mechanism to protect against overloads and short circuits.
It is a 3-pole device (3P), intended to switch and protect three live conductors together, which is typical for three-phase circuits.
The rated current is 40 A (In = 40 A).
It uses a D curve, which is commonly selected for circuits with higher inrush currents (for example, loads that can draw a brief surge on start-up).
The magnetic tripping limit is 12 × In ± 20%, which equates to approximately ``12 × 40 A = 480 A`` (with tolerance).
It is rated at 10,000 A (10 kA) Icn at 400 V AC 50/60 Hz in accordance with EN/IEC 60898-1.
Typical Icu ratings include 10 kA at 440 V AC, 15 kA at 380–415 V AC, and 30 kA at 220–240 V AC (EN/IEC 60947-2).
Yes. It is specified for both AC and DC networks, with an Icu of 15 kA at up to 180 V DC (EN/IEC 60947-2).
The rated insulation voltage (Ui) is 500 V AC, and the rated impulse withstand voltage (Uimp) is 6 kV.
It is designed for fixed mounting on a DIN rail.
Overall dimensions are 85 mm (H) × 54 mm (W) × 78.5 mm (D). The width corresponds to 6 modules of 9 mm pitch.
It accepts single conductors at the top or bottom: 1–35 mm² rigid and 1–25 mm² flexible.
Recommended tightening torque is 3.5 N·m, and the strip length is 14 mm for top or bottom connection.
Yes. It includes a contact position indicator and a local trip indicator, with a toggle actuator for manual operation.
No. Earth-leakage protection is provided via a separate block. If you need residual-current protection, it is typically added as an additional module rather than being integrated into this MCB (e.g., Schneider A9F85340 is specified with separate earth-leakage protection).
It is rated IP20, with an operating ambient temperature range of -35 to 70 °C, storage range of -40 to 85 °C, and operating altitude of 0 to 2000 m.
This content has been produced using multiple sources. EU Automation takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
All parts new or reconditioned are covered by EU Automation 12 month warranty
No hassle returns policy
Dedicated customer support team
We understand that credit is a necessary part of business and offer credit agreements on request, subject to status.
Payment optionsWe accept Bank transfers and the following methods of payment:
All transactions are handled securely by HSBC and HSBC Merchant Services. For more information, please visit our dedicated payments page.
Global supplier of quality automation and control components
Dispose of your old unit by exchanging it for a working part.
A comprehensive repair service for faulty equipment.
You don’t need tights and a cape to be a hero.