steve
Got hold of Sime for a Carrier card for…
Got hold of Sime for a Carrier card for a chiller. Machine down in a factory. Received the new card in express time machine and plant now up and running fantastic service form Sime
3 months ago
Full 12-month warranty
Available for dispatch immediately
We deliver worldwide
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
All orders are subject to product availability. See our T&Cs.
Ask our team
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
| Specification | Description |
|---|---|
| Manufacturer | Schneider |
| Part Number | A9F05340 |
| Product Type | Miniature circuit breaker |
| Range | Acti9 |
| Product Name | Acti9 iC60 |
| Device Short Name | iC60N |
| Device Application | Electrical distribution |
| Poles | 3P |
| Protected Poles | 3 |
| Rated Current | 40 A |
| Trip Curve | D curve |
| Trip Unit Technology | Thermal-magnetic |
| Network Type | AC/DC |
| Network Frequency | 50/60 Hz |
| Breaking Capacity | 6000 A Icn at 400 V AC under EN/IEC 60898-1; up to 10 kA Icu at 380–415 V AC under EN/IEC 60947-2 |
| Magnetic Tripping Limit | 12 x In ±20% |
| Rated Service Breaking Capacity | 6000 A at 400 V AC under EN/IEC 60898-1; 7.5 kA at 380–415 V AC under EN/IEC 60947-2 |
| Utilization Category | Category A |
| Suitability for Isolation | Yes |
| Standards | EN 60898-1, IEC 60898-1, EN 60947-2, IEC 60947-2 |
| Limitation Class | Class 3 |
| Rated Insulation Voltage | 500 V AC |
| Rated Impulse Withstand Voltage | 6 kV |
| Control Type | Toggle |
| Local Signaling | Trip indicator |
| Contact Position Indicator | Yes |
| Mounting | DIN rail |
| Module Width | 6 x 9 mm pitches |
| Height | 91 mm / 3.58 in |
| Width | 54 mm / 2.13 in |
| Depth | 78.5 mm / 3.09 in |
| Net Weight | 0.375 kg / 0.83 lb |
| Color | White |
| Mechanical Durability | 20,000 cycles |
| Electrical Durability | 10,000 cycles |
| Terminal Type | Double terminals at top or bottom |
| Connection Capacity | 1–35 mm² rigid conductors; 1–25 mm² flexible conductors |
| Wire Stripping Length | 14 mm / 0.55 in |
| Tightening Torque | 3.5 N.m / 30.98 lbf.in |
| Earth-Leakage Protection | Separate block |
| IP Rating | IP20 |
| Pollution Degree | 3 |
| Overvoltage Category | IV |
| Tropicalization | 2 |
| Relative Humidity | 95% at 55 °C / 131 °F |
| Operating Ambient Temperature | -35 to 70 °C / -31 to 158 °F |
| Storage Ambient Temperature | -40 to 85 °C / -40 to 185 °F |
| Commodity Code | 853620 |
This is a miniature circuit breaker designed for distribution applications. It is part of the Acti9 iC60 range and is used to protect electrical circuits against overloads and short circuits.
The rated current is 40 A, making it suitable for circuits where a 40 amp protective device is required.
It is a 3-pole device with three protected poles, suitable for three-phase circuit protection applications.
It uses a D curve. This curve is typically selected for circuits with higher inrush currents, such as certain motor, transformer, or inductive load applications.
The device has a breaking capacity of 6000 A under IEC 60898-1 at 400 V AC, and up to 10 kA under IEC 60947-2 at 380 to 415 V AC.
This miniature circuit breaker conforms to EN/IEC 60898-1 and EN/IEC 60947-2, which are key standards for low-voltage circuit protection devices.
Yes. The A9F05340 is specified for AC and DC network use, with ratings dependent on the voltage and applicable standard.
It is designed for DIN rail mounting, which is common in industrial and commercial electrical panels.
The unit measures approximately 91 mm high, 54 mm wide, and 78.5 mm deep.
It has double terminals at the top or bottom. The terminals accept rigid conductors from 1 to 35 mm² and flexible conductors from 1 to 25 mm².
The specified tightening torque for the top or bottom terminals is 3.5 N.m.
The operating ambient air temperature range is -35 °C to 70 °C, with a storage temperature range of -40 °C to 85 °C.
Yes. It includes a contact position indicator and local trip indication, helping users identify the breaker state during inspection.
The device has an IP20 degree of protection according to IEC 60529 and EN 60529.
The commodity code listed for this circuit breaker is 853620, which applies to automatic circuit breakers for a voltage not exceeding 1,000 V.
This content has been produced using multiple sources. EU Automation takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
All parts new or reconditioned are covered by EU Automation 12 month warranty
No hassle returns policy
Dedicated customer support team
We understand that credit is a necessary part of business and offer credit agreements on request, subject to status.
Payment optionsWe accept Bank transfers and the following methods of payment:
All transactions are handled securely by HSBC and HSBC Merchant Services. For more information, please visit our dedicated payments page.
Global supplier of quality automation and control components
Dispose of your old unit by exchanging it for a working part.
A comprehensive repair service for faulty equipment.
You don’t need tights and a cape to be a hero.
Get parts fast and feel like a legend, just like Jeff.