steve
Got hold of Sime for a Carrier card for…
Got hold of Sime for a Carrier card for a chiller. Machine down in a factory. Received the new card in express time machine and plant now up and running fantastic service form Sime
3 months ago
Full 12-month warranty
Available for dispatch immediately
We deliver worldwide
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
All orders are subject to product availability. See our T&Cs.
Ask our team
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
It provides overcurrent protection for electrical distribution circuits by tripping on overloads (thermal element) and short-circuits (magnetic element), helping to protect cabling and connected loads.
It is a 3-pole device, designed to switch and protect three conductors together. This is commonly used for three-phase circuits where simultaneous disconnection is required.
The rated current is 2 A. In normal operation it is intended to carry up to 2 A continuously under the specified reference conditions.
A C curve breaker is intended for circuits with moderate inrush currents (for example, small motors, transformers, or groups of lamps). The magnetic (instantaneous) trip operates at approximately 8 × In (with tolerance), so for 2 A this is around 16 A for instantaneous tripping.
It is specified for both AC and DC networks. Ensure the system voltage and breaking capacity requirements match your installation conditions.
For installations assessed under EN/IEC 60898-1 at 400 V AC, the rated short-circuit breaking capacity (Icn) is 6 kA. For applications assessed under EN/IEC 60947-2, higher breaking capacities are specified depending on voltage (for example, up to 50 kA at several AC voltage ranges). Selection should be based on the prospective fault current at the point of installation and the standard used for the panel.
Yes. It is stated as suitable for isolation in accordance with the relevant standards listed on the product documentation, meaning it can be used for disconnection/isolation functions when correctly installed.
It is designed for DIN rail mounting. The device width is 6 modules (9 mm pitch), which corresponds to 54 mm overall width.
Typical overall dimensions are approximately 91 mm (height) × 54 mm (width) × 78.5 mm (depth). Allow extra clearance for wiring bend radius and upstream/downstream accessories.
It uses double terminals (top or bottom). Typical accepted sizes are 1 to 25 mm² for rigid conductors and 1 to 16 mm² for flexible conductors, depending on the conductor type and ferrule practice.
A stripping length of 14 mm is specified, with a typical tightening torque of 2 N·m for top or bottom connections. Using the correct torque helps ensure a secure, low-resistance connection.
Yes. It includes a contact position indicator and local signalling with a trip indicator, helping distinguish between an intentional switch-off and a trip event.
The specified ambient operating temperature range is -35 °C to +70 °C. Storage temperature is specified down to -40 °C and up to +85 °C.
The device is rated IP20, which is typical for components intended to be installed inside an enclosure that provides the required overall protection for the installation environment.
Earth-leakage protection is described as using a separate block, meaning residual-current protection is achieved by pairing with an appropriate add-on device rather than being integrated into the breaker itself.
It is specified as conforming to IEC/EN 60898-1 and IEC/EN 60947-2. In practice, this supports use in a broad range of distribution and panel-building contexts where those standards apply.
This content has been produced using multiple sources. EU Automation takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
All parts new or reconditioned are covered by EU Automation 12 month warranty
No hassle returns policy
Dedicated customer support team
We understand that credit is a necessary part of business and offer credit agreements on request, subject to status.
Payment optionsWe accept Bank transfers and the following methods of payment:
All transactions are handled securely by HSBC and HSBC Merchant Services. For more information, please visit our dedicated payments page.
Global supplier of quality automation and control components
Dispose of your old unit by exchanging it for a working part.
A comprehensive repair service for faulty equipment.
You don’t need tights and a cape to be a hero.
Get parts fast and feel like a legend, just like Jeff.