steve
Got hold of Sime for a Carrier card for…
Got hold of Sime for a Carrier card for a chiller. Machine down in a factory. Received the new card in express time machine and plant now up and running fantastic service form Sime
3 months ago
Full 12-month warranty
Available for dispatch immediately
We deliver worldwide
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
All orders are subject to product availability. See our T&Cs.
Ask our team
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
| Specification | Description |
|---|---|
| Manufacturer | Schneider Electric |
| Part Number | 9001KR16 |
| Product Range | Harmony 9001K |
| Device Short Name | 9001K |
| Product Type | Emergency stop push-button head (operator head only) |
| Function | Emergency switching off operator head for use with separate contact blocks |
| Operator Style | Red mushroom, unmarked |
| Mushroom Diameter | 40 mm (Ø 40 mm) |
| Operator Action / Release | Latching trigger action, turn-to-release |
| Mounting Hole Diameter | 30 mm |
| Bezel Material | Metal (chromium plated metal on some versions) |
| Head Material | Plastic |
| Head Shape | Round |
| Operating Positions | Any position |
| Operator Positions | 2 positions |
| Contacts Included | None (supplied without contact block) |
| Compatible Contact Blocks | 9001KA.. contact block family |
| Max Contact Block Stacking | Up to 3 levels (maximum of 6 contact blocks) |
| Mechanical Durability | 5,000,000 cycles |
| Protective Treatment | TC |
| IP Rating | IP66 |
| NEMA Enclosure Rating | NEMA 1, 2, 3, 3R, 4, 6, 12, 13 |
| Overvoltage Category | Class II (IEC 61140) |
| Operating Temperature | -25 to 70 °C (-13 to 158 °F) |
| Storage Temperature | -40 to 70 °C (-40 to 158 °F) |
| Vibration Resistance | 7 gn (2…500 Hz), IEC 60068-2-6 |
| Shock Resistance | 50 gn, IEC 60068-2-27 |
| Standards (Referenced) | IEC 60947-1, IEC 60947-5-1, IEC 60947-5-4, IEC 60947-5-5, IEC 60204-1 (with appropriate legend plate), ISO 13850 (with appropriate legend plate), JIS C 4520, JIS C 852, CSA C22.2 No 14, UL 508 / UL 60947-5-5 |
| Overall Dimensions (CAD) | Width: 40 mm; Height: 40 mm; Depth: 116 mm |
| Panel Thickness (Typical) | 1 to 6 mm (0.04 to 0.24 in) |
| Net Weight | 0.141 kg (0.311 lb) |
It uses a latching trigger action with a turn-to-release mechanism. Pressing the mushroom head latches the operator, and a twist action is used to reset it.
No. This is the operator/head only (without contact block). It is designed to be used with compatible 9001KA.. contact blocks to build a complete device.
It mounts in a standard 30 mm panel hole.
It is intended for panel thickness from 1 to 6 mm (approximately 0.04 to 0.24 in.).
The bezel is metal, and the mushroom head/operator is plastic with a red cap.
It is a red mushroom operator with a 40 mm diameter and is unmarked.
It is rated IP66 and is also suitable for multiple NEMA enclosure ratings (including 1, 2, 3, 3R, 4, 6, 12, and 13) when correctly installed as part of an assembly.
Operating ambient temperature is -25 to 70°C (approximately -13 to 158°F). Storage ambient temperature is -40 to 70°C (approximately -40 to 158°F).
Yes. The specified operating position is any position.
The mounting arrangement allows up to 3 levels of contact blocks, with a maximum of 6 contact blocks total (depending on the contact block type and configuration).
The specified mechanical durability is 5,000,000 cycles.
Certain emergency stop-related standards are referenced when used with an appropriate emergency stop legend plate type (for example, 9001KN). The operator head itself (e.g., 9001KR16) is one component within the overall device assembly.
This content has been produced using multiple sources. EU Automation takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
All parts new or reconditioned are covered by EU Automation 12 month warranty
No hassle returns policy
Dedicated customer support team
We understand that credit is a necessary part of business and offer credit agreements on request, subject to status.
Payment optionsWe accept Bank transfers and the following methods of payment:
All transactions are handled securely by HSBC and HSBC Merchant Services. For more information, please visit our dedicated payments page.
Global supplier of quality automation and control components
Dispose of your old unit by exchanging it for a working part.
A comprehensive repair service for faulty equipment.
You don’t need tights and a cape to be a hero.
Get parts fast and feel like a legend, just like Jeff.